Adaptive DC-Link Voltage-Controlled PV Grid-Connected DTL-VSI With Reduced Switching Losses and Switching Frequency

被引:0
作者
Rao, Koyyana Srinivasa [1 ]
Kumar, Ganjikunta Siva [1 ]
Karasala, Chinna [2 ]
机构
[1] Natl Inst Technol, Dept Elect Engn, Hanamkonda 506004, Telangana, India
[2] Quest Global Engn Pvt Ltd, Bengaluru 560103, Karnataka, India
关键词
Voltage control; Inverters; Power harmonic filters; Switches; Switching loss; Control systems; Switching frequency; Adaptive dc-link voltage control scheme; dual two-level voltage source inverter; model predictive control (MPC); switching frequency; switching losses; DUAL 2-LEVEL INVERTERS; ACTIVE POWER FILTER; 3-PHASE; DSTATCOM; COMPENSATION; EQUALIZATION; PERFORMANCE;
D O I
10.1109/JESTPE.2024.3396911
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article discusses a photovoltaic (PV) grid-connected dual two-level voltage source inverter (GCDTL-VSI) to improve the power quality, reliability, and efficiency of the grid. In PVGCDTL-VSI, VSI-1 is employed to compensate the current-related power quality concern, while VSI-2 is employed to transfer real power to the load and grid. In the literature, the dc-link voltage maintains constant at the input terminal of VSI-1 under low-power injection. As a result, there will be significant switching losses and stress on the inverter switches. In the proposed method, VSI-1 with LC-filter, and an adaptive dc-link voltage control technique is used to alleviate the switching losses and stress on the inverter switches. In addition, the two-leg VSI that employs for supply real power to the load and grid instead of the conventional approach uses three-leg VSI. In PVGCDTL-VSI, a model predictive control (MPC) with a multiconstraint technique is used to generate the switching pulses, dc-link capacitor voltage balancing, and reduce switching frequency. To reduce the weighting factor control complexity, a technique for order preference by similarity to ideal solution (TOPSIS) approach is employed in PVGCDTL-VSI. To evaluate the effectiveness and performance of the PVGCDTL-VSI, simulation and experimental tests are carried out.
引用
收藏
页码:4004 / 4014
页数:11
相关论文
共 43 条
  • [41] Reactive Power Compensation and DC link Voltage Control using Fuzzy-PIon Grid-connected PV System with d-STATCOM
    Li, Hui
    Huang, Yaomei
    Lu, Junwei
    2016 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2016, : 1240 - 1244
  • [42] Space-Vector-Based Hybrid PWM Strategy for Reduced DC-Link Capacitor Current Stress in the Postfault Grid-Connected Three-Phase Rectifier
    Zeng, Zhiyong
    Zheng, Weiyi
    Zhao, Rongxiang
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2016, 63 (08) : 4989 - 5000
  • [43] Compensation of DC-Link Voltage Fluctuation for Railway Traction PMSM in Multiple Low-Switching-Frequency Synchronous Space Vector Modulation Modes
    Zhao, Shuofeng
    Huang, Xiaoyan
    Fang, Youtong
    Zhang, Jian
    IEEE TRANSACTIONS ON VEHICULAR TECHNOLOGY, 2018, 67 (01) : 235 - 250