Adaptive DC-Link Voltage-Controlled PV Grid-Connected DTL-VSI With Reduced Switching Losses and Switching Frequency

被引:0
作者
Rao, Koyyana Srinivasa [1 ]
Kumar, Ganjikunta Siva [1 ]
Karasala, Chinna [2 ]
机构
[1] Natl Inst Technol, Dept Elect Engn, Hanamkonda 506004, Telangana, India
[2] Quest Global Engn Pvt Ltd, Bengaluru 560103, Karnataka, India
关键词
Voltage control; Inverters; Power harmonic filters; Switches; Switching loss; Control systems; Switching frequency; Adaptive dc-link voltage control scheme; dual two-level voltage source inverter; model predictive control (MPC); switching frequency; switching losses; DUAL 2-LEVEL INVERTERS; ACTIVE POWER FILTER; 3-PHASE; DSTATCOM; COMPENSATION; EQUALIZATION; PERFORMANCE;
D O I
10.1109/JESTPE.2024.3396911
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article discusses a photovoltaic (PV) grid-connected dual two-level voltage source inverter (GCDTL-VSI) to improve the power quality, reliability, and efficiency of the grid. In PVGCDTL-VSI, VSI-1 is employed to compensate the current-related power quality concern, while VSI-2 is employed to transfer real power to the load and grid. In the literature, the dc-link voltage maintains constant at the input terminal of VSI-1 under low-power injection. As a result, there will be significant switching losses and stress on the inverter switches. In the proposed method, VSI-1 with LC-filter, and an adaptive dc-link voltage control technique is used to alleviate the switching losses and stress on the inverter switches. In addition, the two-leg VSI that employs for supply real power to the load and grid instead of the conventional approach uses three-leg VSI. In PVGCDTL-VSI, a model predictive control (MPC) with a multiconstraint technique is used to generate the switching pulses, dc-link capacitor voltage balancing, and reduce switching frequency. To reduce the weighting factor control complexity, a technique for order preference by similarity to ideal solution (TOPSIS) approach is employed in PVGCDTL-VSI. To evaluate the effectiveness and performance of the PVGCDTL-VSI, simulation and experimental tests are carried out.
引用
收藏
页码:4004 / 4014
页数:11
相关论文
共 43 条
  • [21] Grid-Connected Induction Motor Using a Floating DC-Link Converter under Unbalanced Voltage Sag
    Cunha, Maxsuel F.
    Jacobina, Cursino B.
    de Freitas, Nayara B.
    2019 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2019, : 1859 - 1866
  • [22] Model Predictive Control of Grid-Connected Inverters for PV Systems With Flexible Power Regulation and Switching Frequency Reduction
    Hu, Jiefeng
    Zhu, Jianguo
    Dorrell, David G.
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2015, 51 (01) : 587 - 594
  • [23] Sensorless DC-link voltage regulation strategy for single-phase grid-connected solar photovoltaic systems
    Owais, Raja
    Iqbal, Sheikh Javed
    INTERNATIONAL JOURNAL OF MODELLING IDENTIFICATION AND CONTROL, 2022, 41 (1-2) : 133 - 142
  • [24] A Precise Switching Frequency Formulation of Hysteresis-Controlled Grid-Connected Inverters Considering Nonlinear Ripple Current
    Viswadev, Roopa
    Perumal, Venkatesa B. V.
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2022, 69 (06) : 5835 - 5843
  • [25] Improving Double-Line-Frequency Voltage Ripple Rejection Capability of DC/DC Converter in Grid Connected Two-Stage PV Inverter Using DC-link Voltage Feedforward
    Viinamaki, Jukka
    Jokipii, Juha
    Suntio, Teuvo
    2016 18TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'16 ECCE EUROPE), 2016,
  • [26] DC-Link Voltage Dynamics of Three-Level Four-Wire Grid-Connected Converters During Harmonics Injection Operations
    Guenter, Sandro
    Yang, Jiajun
    Buticchi, Giampaolo
    Fuchs, Friedrich W.
    Liserre, Marco
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2023, 70 (08) : 8000 - 8008
  • [27] Assessment and Mitigation of Dynamic Instabilities in Single-Stage Grid-Connected Photovoltaic Systems With Reduced DC-Link Capacitance
    Magableh, Mohammad Adnan K.
    Radwan, Amr
    Mohamed, Yasser Abdel-Rady, I
    IEEE ACCESS, 2021, 9 : 55522 - 55536
  • [28] A New Soft-Switching Control Technique and Loss Analysis for Parallel Resonant DC-Link Inverter Connected to the Grid
    Donuk, Hakan
    Gumus, Bilal
    TEHNICKI VJESNIK-TECHNICAL GAZETTE, 2022, 29 (05): : 1576 - 1584
  • [29] DC-Link Voltage Control of a Grid-Connected Solar Photovoltaic System for Fault Ride-Through Capability Enhancement
    Mohamed, S. Raja
    Jeyanthy, P. Aruna
    Devaraj, D.
    Shwehdi, M. H.
    Aldalbahi, Adel
    APPLIED SCIENCES-BASEL, 2019, 9 (05):
  • [30] Reduction in switching losses/DC bus requirement for a grid-connected inverter with minimal sensors using PMR-OCC
    Satpathy, Guddy
    De, Dipankar
    ELECTRICAL ENGINEERING, 2024, 106 (01) : 509 - 519