Characterization of a Soft Ionization by Chemical Reaction in Transfer Ion Source Hyphenated With Supercritical Fluid Chromatography-Tandem Mass Spectrometry

被引:4
作者
Bhakta, Niray [1 ]
Kaplitz, Alexander S. [1 ]
Black, Destini [1 ]
Schug, Kevin A. [1 ]
机构
[1] Univ Texas Arlington, Dept Chem & Biochem, Arlington, TX 76019 USA
基金
美国国家科学基金会;
关键词
dielectric barrier discharge ionization; polycyclic aromatic hydrocarbon; SFC optimization; SICRIT; POLYCYCLIC AROMATIC-HYDROCARBONS; BARRIER DISCHARGE IONIZATION; LIQUID-CHROMATOGRAPHY; ELECTROSPRAY-IONIZATION; PLASMA; QUANTIFICATION;
D O I
10.1002/jssc.202400500
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A commercially available dielectric barrier discharge ionization (DBDI) source was tested with supercritical fluid chromatography-mass spectrometry (SFC-MS). The compound mixture investigated comprised caffeine, theobromine, theophylline, uracil, testosterone, and pyrene, diluted in methanol. Dynamic response ranges were evaluated with multiple injections at different concentrations. Precision studies demonstrated the robustness and sensitivity of the ionization source across a concentration range of 10-1000 ng/mL. Results from this experiment showed linear regression of 0.99 or greater for all analytes tested over the range with a relative standard deviation (RSD) of less than 10% down to 10 ng/mL for all analytes except theobromine, which had an RSD of less than 10% down to 25 ng/mL. Notably, this study marks the first investigation of sensitivity for coupling a commercial DBDI source with SFC; a limit of detection less than 1 ng/mL was achieved for all compounds. This study demonstrates chromatographic separation by SFC and MS analysis for compounds that ionize poorly using traditional atmospheric pressure ionization, such as polycyclic aromatic hydrocarbons. Combining SFC with the DBDI source opens promising avenues for analyzing compounds that were previously challenging to characterize with standard atmospheric pressure ionization techniques.
引用
收藏
页数:10
相关论文
共 48 条
[1]   Investigations of Analyte-Specific Response Saturation and Dynamic Range Limitations in Atmospheric Pressure Ionization Mass Spectrometry [J].
Alfaro, Clint M. ;
Uwakweh, Agbo-Oma ;
Todd, Daniel A. ;
Ehrmann, Brandie M. ;
Cech, Nadja B. .
ANALYTICAL CHEMISTRY, 2014, 86 (21) :10639-10645
[2]   Comparison of different approaches for evaluation of the detection and quantitation limits of a purity method: A case study using a capillary isoelectrofocusing method for a monoclonal antibody [J].
Apostol, Izydor ;
Miller, Karen J. ;
Ratto, Joseph ;
Kelner, Drew N. .
ANALYTICAL BIOCHEMISTRY, 2009, 385 (01) :101-106
[3]   The correlation coefficient:: An overview [J].
Asuero, AG ;
Sayago, A ;
González, AG .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2006, 36 (01) :41-59
[4]   Mass Spectrometry, Review of the Basics: Ionization [J].
Awad, Hanan ;
Khamis, Mona M. ;
El-Aneed, Anas .
APPLIED SPECTROSCOPY REVIEWS, 2015, 50 (02) :158-175
[5]   Review on atmospheric pressure ionization sources for gas chromatography-mass spectrometry. Part I: Current ion source developments and improvements in ionization strategies [J].
Ayala-Cabrera, Juan F. ;
Montero, Lidia ;
Meckelmann, Sven W. ;
Uteschil, Florian ;
Schmitz, Oliver J. .
ANALYTICA CHIMICA ACTA, 2023, 1238
[6]   Excited-State N Atoms Transform Aromatic Hydrocarbons into N-Heterocycles in Low-Temperature Plasmas [J].
Begley, Alina, I ;
Shuman, Nicholas S. ;
Long, Bryan A. ;
Kampf, Robin ;
Gyr, Luzia ;
Viggiano, Albert A. ;
Zenobi, Renato .
JOURNAL OF PHYSICAL CHEMISTRY A, 2022, 126 (10) :1743-1754
[7]   Instrumentation for analytical scale supercritical fluid chromatography [J].
Berger, Terry A. .
JOURNAL OF CHROMATOGRAPHY A, 2015, 1421 :171-183
[8]   Detection and validated quantification of toxic alkaloids in human blood plasma - comparison of LC-APCI-MS with LC-ESI-MS/MS [J].
Beyer, Jochen ;
Peters, Frank T. ;
Kraemer, Thomas ;
Maurer, Hans H. .
JOURNAL OF MASS SPECTROMETRY, 2007, 42 (05) :621-633
[9]   Liquid chromatography-dielectric barrier discharge ionization mass spectrometry for the analysis of neutral lipids of archaeological interest [J].
Bouza, Marcos ;
Garcia-Martinez, Julio ;
Gilbert-Lopez, Bienvenida ;
Moreno-Gonzalez, David ;
Rocio-Bautista, Priscilla ;
Parras-Guijarro, David ;
Sanchez-Vizcaino, Alberto ;
Brandt, Sebastian ;
Garcia-Reyes, Juan F. ;
Molina-Diaz, Antonio ;
Franzke, Joachim .
JOURNAL OF SEPARATION SCIENCE, 2022, 45 (16) :3105-3114
[10]   Development of a fast-switching dual (ESI/APCI) ionization source for liquid chromatography/mass spectrometry [J].
Brecht, Dominik ;
Uteschil, Florian ;
Schmitz, Oliver J. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2020, 34 (17)