Molecular Imprinting-Based Ratiometric Fluorescence Nanosensor and Kit for Rapid and Visual Detection of Folic Acid

被引:5
|
作者
Wen, Yuhao [1 ,2 ]
Sun, Dani [1 ]
Fu, Xinyue [1 ]
Jin, Yuming [1 ,2 ]
Yu, Jialuo [1 ]
Xu, Lizhou [3 ]
Song, Zhihua [4 ]
Chen, Lingxin [1 ]
Li, Jinhua [1 ,2 ]
机构
[1] Chinese Acad Sci, Shandong Res Ctr Coastal Environm Engn & Technol, CAS Key Lab Coastal Environm Proc & Ecol Remediat, Yantai Inst Coastal Zone Res,Shandong Key Lab Coas, Yantai 264003, Peoples R China
[2] Harbin Inst Technol Weihai, Sch Marine Sci & Technol, Weihai 264209, Peoples R China
[3] Zhejiang Univ, Coll Biosyst Engn & Food Sci, Hangzhou 310058, Peoples R China
[4] Yantai Univ, Sch Pharm, Collaborat Innovat Ctr Adv Drug Delivery Syst & Bi, Minist Educ,Key Lab Mol Pharmacol & Drug Evaluat, Yantai 264005, Peoples R China
基金
中国国家自然科学基金;
关键词
ratiometric fluorescence; molecular imprinting; nanosensor; folic acid; kit; SENSOR;
D O I
10.1021/acsanm.4c01058
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Molecular imprinting-based ratiometric fluorescence (MI-RFL) nanosensors receive increasing concerns in various fields such as food security, owing to high selectivity and sensitivity, nondestruction, convenience, visualization, etc. Herein, a ternary-emission MI-RFL nanosensor was facilely constructed by postimprinting mixing (PIM) red-emission molecularly imprinted polymers (r-MIPs) and green MIPs (g-MIPs) for rapid and visual detection of folic acid (FA) in food samples. The two fluorescent MIPs were prepared using a sol-gel surface imprinting one-pot method, with FA as template molecules, SiO2 nanoparticles as supporting materials, 3-mercaptopropionic acid-modified red CdTe quantum dots (CdTe QDs), and glutathione-modified green CdTe QDs as fluorescence sources, respectively. Under the optimal conditions, a good linearity ranging from 0.05 to 50 ppm was attained accompanied by rich color evolution, and limit of detection was down to 0.005 ppm. Then, FA tablets and milk powder were tested, and almost consistent FA contents with that of actual results were found, and recoveries were 89.39-103.43% with relative standard deviations less than 3.37%. Furthermore, the nanosensor-based kit was fabricated to analyze FA tablets by observing color change in 9 min, indicating kit's high accuracy and practicality. This study can provide a universal point-of-care testing method for on-site monitoring of targets in complicated matrices.
引用
收藏
页码:9565 / 9575
页数:11
相关论文
共 50 条
  • [41] A FRET-based ratiometric fluorescent aptasensor for rapid and onsite visual detection of ochratoxin A
    Qian, Jing
    Wang, Kan
    Wang, Chengquan
    Hua, Mengjuan
    Yang, Zhenting
    Liu, Qian
    Mao, Hanping
    Wang, Kun
    ANALYST, 2015, 140 (21) : 7434 - 7442
  • [42] 11-Mercaptoundecanoic acid capped gold nanoclusters as a fluorescent probe for specific detection of folic acid via a ratiometric fluorescence strategy
    Meng, Lei
    Yin, Jian-Hang
    Yuan, Yaqing
    Xu, Na
    RSC ADVANCES, 2018, 8 (17): : 9327 - 9333
  • [43] Rapid visual detection of okadaic acid based on aptamer
    Pan, Cheng
    Zhu, Xinwei
    Yang, Yan
    Wang, Hongzhao
    Liu, Jiahui
    Chen, Huan
    Dong, Yiyang
    Chinese Journal of Analysis Laboratory, 2021, 40 (06) : 686 - 691
  • [44] Preparation of ratiometric electrochemical sensor based on molecular imprinting copolymer and β-cyclodextrin recognition for the reliable detection of dinotefuran
    Li, Tianning
    Liu, Yiwei
    Zhao, Faqiong
    Zeng, Baizhao
    FOOD CHEMISTRY, 2025, 466
  • [45] Microvolume ratiometric fluorescence capillary imprinted array sensor based on bimetallic-nanozyme for rapid intelligent visual detection of five glucocorticoids
    Tang, Kangling
    Zuo, Weijia
    Tan, Yongkang
    Wang, Xiangni
    Zhou, Qin
    Zhang, Zhaohui
    SENSORS AND ACTUATORS B-CHEMICAL, 2025, 432
  • [46] PVA-based nanobiosensor for ultrasensitive detection of folic acid by fluorescence quenching
    Chakravarty, Sudesna
    Dutta, Priyanka
    Kalita, Sanjeeb
    Sen Sarma, Neelotpal
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 232 : 243 - 250
  • [47] Portable smartphone-based RecJf exonuclease-modulated enhanced ratiometric fluorescence bioplatform for rapid visual detection of As3+
    Wang, Li
    Pan, Yi
    Wei, Yang
    Wang, Zhengwu
    Wei, Xinlin
    FOOD CHEMISTRY, 2024, 454
  • [48] Rational construction of a triple emission molecular imprinting sensor for accurate naked-eye detection of folic acid
    Yang, Qian
    Li, Chuyao
    Li, Jinhua
    Wang, Xiaoyan
    Arabi, Maryam
    Peng, Hailong
    Xiong, Hua
    Chen, Lingxin
    NANOSCALE, 2020, 12 (11) : 6529 - 6536
  • [49] Ratiometric fluorescence probe based on boric acid-modified carbon dots and alizarin red for sensitive and rapid detection of glyphosate
    Yang, Jingqi
    Wang, Xinru
    Yu, Ying
    Cao, Yujuan
    Guo, Manli
    Hu, Xiaogang
    Wang, Li
    Lin, Bixia
    MICROCHIMICA ACTA, 2024, 191 (11)
  • [50] Ratiometric Fluorescence Capillary Sensor-Integrated Molecular Imprinting for Simultaneous Detection of Two Biological Indicators of Parkinson?s Disease
    Tang, Sisi
    Wu, Xiaodan
    Zhao, Pengfei
    Tang, Kangling
    Chen, Yu
    Fu, Jinli
    Lei, Huibin
    Yang, Zhaoxia
    Zhang, Zhaohui
    ANALYTICAL CHEMISTRY, 2022, 94 (49) : 17223 - 17231