摘要
As the operating speed of electric multiple units (EMUs) in high-speed railways increases, pantograph-catenary (PC) detachment arcing occurs frequently. The resulting vehicular-grounding electromagnetic transients are related to the dynamic characteristics of the arc length. During large detachment, the processes of arc extinction and arc reignition may occur, resulting in more severe train body (TB) over-voltages and adverse effects on some vehicular electronic devices. As an extension of the previous works, this paper aims to establish a suitable PC arc model to examine the TB transient voltages. To begin with, the arc length dynamic characteristics are reasonably analyzed to deduce the relationship between the detachment distance and the arc length via the chain arc model. Then, the dynamic characteristics of the arc length are introduced, and an arc modeling scheme is proposed to elaborate the vehicle-grid electric power model for EMUs encountering various arcing scenarios. Based on this, the transient over-voltages are analyzed, accounting for both the arc extinction and arc reignition, as well as the mutual influences of multiple detachments in a short time. The influential factors, including arc length characteristics, phase angle, excitation inductance, and grounding parameters, are also involved in the performed analyses.
引用
收藏
页数:25
相关论文
共 38 条
  • [1] [Anonymous], 2002, EN50318-2002
  • [2] Phototube sensor for monitoring the quality of current collection on overhead electrified railways
    Bruno, O
    Landi, A
    Papi, M
    Sani, L
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART F-JOURNAL OF RAIL AND RAPID TRANSIT, 2001, 215 (03) : 231 - 241
  • [3] Buhrkall L., 2005, ELECTRISCHE BAHNEN, V103, P380
  • [4] Carson J. R., 1926, The Bell System Technical Journal, V5, P539, DOI DOI 10.1002/J.1538-7305.1926.TB00122.X
  • [5] [陈旭坤 Chen Xukun], 2016, [高电压技术, High Voltage Engineering], V42, P3593
  • [6] An improved arc model before current zero based on the combined Mayr and Cassie arc models
    Guardado, JL
    Maximov, SG
    Melgoza, E
    Naredo, JL
    Moreno, P
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (01) : 138 - 142
  • [7] HABEDANK U, 1988, ETZ ARCHIV, V10, P339
  • [8] Research on Transient Over-Voltages of High-Speed Train Passing Articulated Split-Section Insulator
    Huang, Ke
    Lin, Guobin
    Liu, Zhigang
    Yang, Yunhan
    [J]. IEEE TRANSACTIONS ON TRANSPORTATION ELECTRIFICATION, 2023, 9 (01): : 1664 - 1682
  • [9] Grounding Behavior and Optimization Analysis of Electric Multiple Units in High-Speed Railways
    Huang, Ke
    Liu, Zhigang
    Zhu, Feng
    Deng, Yunchuan
    [J]. IEEE TRANSACTIONS ON TRANSPORTATION ELECTRIFICATION, 2021, 7 (01) : 240 - 255
  • [10] Ji Liang, 2009, Proceedings of the CSEE, V29, P107