Evaluation and Correction of PurpleAir Temperature and Relative Humidity Measurements

被引:1
|
作者
Couzo, Evan [1 ]
Valencia, Alejandro [2 ]
Gittis, Phoebe [3 ]
机构
[1] Univ N Carolina, Dept Atmospher Sci, Asheville, NC 28804 USA
[2] Sonoma Technol Inc, Petaluma, CA 94954 USA
[3] Univ N Carolina, Dept Environm Studies, Asheville, NC 28804 USA
关键词
PurpleAir; low-cost sensor; air pollution; temperature; relative humidity; AIR-POLLUTION; PARTICULATE MATTER; LABORATORY EVALUATION; EXPOSURE; SENSORS; CALIBRATION; MORTALITY; HEAT;
D O I
10.3390/atmos15040415
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The PurpleAir PA-II sensor provides low-cost in situ measurements of meteorological variables including temperature and relative humidity (RH), as well as fine particulate matter (PM2.5) in real time. The sensors have been used in several studies investigating intracity differences in temperature and PM2.5. While the adoption and use of low-cost sensors has many benefits, care must be taken to ensure proper calibration and testing. This is true not only for PM2.5 measurements but also for temperature and RH given the synergistic health impacts from extreme heat and air pollution exposure. Here, we compare continuous temperature and RH measurements from a PA-II sensor to measurements from a Campbell Scientific 107 temperature probe and Vaisala HMP45C RH probe. All three instruments were co-located from December 2021 to June 2023 in Asheville, North Carolina. We found that the PA-II has an overall high temperature bias of 2.6 degrees C and root mean square error (RMSE) of 2.8 degrees C. Applying a linear regression correction reduces RMSE to 1.0 degrees C, while applying the constant 4.4 degrees C correction suggested by PurpleAir reduces RMSE to only 2.2 degrees C. Our PA-II RH measurements have a low bias of -17.4% and uncorrected RMSE of 18.5%. A linear regression correction improves the RH RMSE to 4.5%. Applying the constant 4% RH correction suggested by PurpleAir reduces RMSE to only 14.8%. We present new correction factors that differ from those suggested by PurpleAir, which overcorrect the high temperature bias and undercorrect the low RH bias. We also show that our correction factors improve estimates of dewpoint temperature (RMSE of 0.6 degrees C and 0.9 degrees C) compared to the corrections suggested by PurpleAir.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Effects of temperature and relative humidity on microcalorimeter measurements
    Yuan Wenze
    Cui Xiaohai
    Li Yong
    Ma Chao
    PROCEEDINGS OF 2015 IEEE 12TH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS (ICEMI), VOL. 3, 2015, : 1608 - 1611
  • [2] MEMS sensors for temperature, pressure, and relative humidity measurements
    Johari, H
    Pryputniewicz, RJ
    2003 INTERNATIONAL SYMPOSIUM ON MICROELECTRONICS, 2003, 5288 : 739 - 744
  • [3] INTERPRETATION OF TEMPERATURE AND RELATIVE-HUMIDITY MEASUREMENTS IN A CALF HOUSE
    NICKS, B
    CANART, B
    DECHAMPS, P
    ANNALES DE MEDECINE VETERINAIRE, 1986, 130 (02) : 91 - 99
  • [4] LINEARIZING RELATIVE HUMIDITY MEASUREMENTS
    WHITEHAUS, G
    INSTRUMENTS & CONTROL SYSTEMS, 1972, 45 (09): : 72 - +
  • [5] Correction and Accuracy of PurpleAir PM2.5 Measurements for Extreme Wildfire Smoke
    Barkjohn, Karoline K.
    Holder, Amara L.
    Frederick, Samuel G.
    Clements, Andrea L.
    SENSORS, 2022, 22 (24)
  • [6] Temperature and relative humidity measurements and data analysis of five crawl spaces
    Laukkarinen, Anssi
    Vinha, Juha
    11TH NORDIC SYMPOSIUM ON BUILDING PHYSICS (NSB2017), 2017, 132 : 711 - 716
  • [7] Algorithmic Correction of MOS Gas Sensor for Ambient Temperature and Relative Humidity Fluctuations
    Aurora, A.
    IEEE SENSORS JOURNAL, 2022, 22 (15) : 15054 - 15061
  • [8] Comparison of field measurements and calculations of relative humidity and temperature in wood framed walls
    Hagerstedt, S. Olof
    Arfvidsson, Jesper
    THERMOPHYSICS 2010, 2010, : 93 - 101
  • [9] Measurements of relative humidity in a persistent contrail
    Gao, RS
    Fahey, DW
    Popp, PJ
    Marcy, TP
    Herman, RL
    Weinstock, EM
    Smith, JB
    Sayres, DS
    Pittman, JV
    Rosenlof, KH
    Thompson, TL
    Bui, PT
    Baumgardner, DG
    Anderson, BE
    Kok, G
    Weinheimer, AJ
    ATMOSPHERIC ENVIRONMENT, 2006, 40 (09) : 1590 - 1600
  • [10] Optical fibre sensor for simultaneous temperature and relative humidity measurement: Towards absolute humidity evaluation
    He, Chenyang
    Korposh, Serhiy
    Correia, Ricardo
    Liu, Liangliang
    Hayes-Gill, Barrie R.
    Morgan, Stephen P.
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 344