Three-heat-reservoir thermal Brownian heat pump and its performance limits

被引:1
作者
Chen, Lingen [1 ,2 ,3 ]
Qi, Congzheng [1 ,2 ,3 ]
Ge, Yanlin [1 ,2 ,3 ]
Feng, Huijun [1 ,2 ,3 ]
机构
[1] Inst Thermal Sci & Power Engn, Wuhan Inst Technol, Wuhan 430205, Peoples R China
[2] Hubei Prov Engn Technol Res Ctr Green Chem Equipme, Wuhan 430205, Peoples R China
[3] Wuhan Inst Technol, Sch Mech & Elect Engn, Wuhan 430205, Peoples R China
基金
中国国家自然科学基金;
关键词
Non -equilibrium thermodynamics; Three -heat -reservoir heat pump; Thermal Brownian motor; Heating load; Optimal performance; COP; OF-THE-ART; MAXIMUM POWER; EFFICIENCY; TECHNOLOGIES; OPTIMIZATION; MODEL;
D O I
10.1016/j.csite.2024.104224
中图分类号
O414.1 [热力学];
学科分类号
摘要
Three -heat -reservoir (THR) heat pump has the originality of using low-grade heat to achieve pumping heat, and it can recycle waste heat and reduce environmental pollution effectively. Based on the research ideas of macro THR heat pumps and micro three -terminal thermoelectric devices, this paper proposes a THR thermal Brownian heat pump cycle model. This cycle is driven by low-grade "heat" to work, and it may be seen as a combined cycle consisting of a two -reservoir thermal Brownian heat pump and a two -reservoir thermal Brownian engine. Using non equilibrium thermodynamics, expressions for heating load and coefficient of performance (COP) are derived. The coupling relation between external forces of two motors is obtained by solving the heat balance equations, and cycle performance is further obtained. The maximal heating load is obtained by optimizing barrier height, and the lower limit of COP is also given. Results show that the THR thermal Brownian heat pump can achieve pumping heat by using low-grade "heat". The internal parameters affect the coupling between two -heat -reservoir thermal Brownian engine and two -heat -reservoir thermal Brownian heat pump, which determines cycle performance directly. The curve of heating load about COP presents a parabolic -like shape, and an optimal COP exists to maximize heating load.
引用
收藏
页数:10
相关论文
共 50 条
[41]   Thermal performance of greenhouse heating with loop heat pipe solar collector and ground source heat pump [J].
Xu, Zhi ;
Lu, Jiarui ;
Xing, Shiguan .
RESULTS IN ENGINEERING, 2022, 15
[42]   Optimization of thermal performance of a building with ground source heat pump system [J].
Zogou, Olympia ;
Stamatelos, Anastassios .
ENERGY CONVERSION AND MANAGEMENT, 2007, 48 (11) :2853-2863
[43]   Testing and Analysis of Thermal Performance of Ground Source Heat Pump System [J].
Qu Shilin ;
Xu, Ge ;
Liu Yimin ;
Yu Qian .
2011 2ND INTERNATIONAL CONFERENCE ON CHALLENGES IN ENVIRONMENTAL SCIENCE AND COMPUTER ENGINEERING (CESCE 2011), VOL 11, PT B, 2011, 11 :566-572
[44]   Performance of a heat engine from interacting Brownian particles under nonautonomous periodic force [J].
Bassie, Yigermal ;
Tesega, Asmamaw ;
Birhanu, Tibebe ;
Abebe, Yoseph .
EUROPEAN PHYSICAL JOURNAL PLUS, 2023, 138 (08)
[45]   Performance assessment of a heat pump and a concentrated photovoltaic thermal system during the wood drying process [J].
Khouya, Ahmed .
APPLIED THERMAL ENGINEERING, 2020, 180
[46]   Thermo-ecological analysis and optimization performance of an irreversible three-heat-source absorption heat pump [J].
Ahmadi, Mohammad Hossein ;
Ahmadi, Mohammad Ali ;
Mehrpooya, Mehdi ;
Sameti, Mohammad .
ENERGY CONVERSION AND MANAGEMENT, 2015, 90 :175-183
[47]   Thermal performance of a solar-assisted slinky foundation heat exchanger coupled with a heat pump in a cold climate [J].
Davani, Shayan ;
Darbandi, Amirhossein ;
Gruenes, Jordan ;
Hoxie, Alison ;
Mwesigye, Aggrey .
APPLIED THERMAL ENGINEERING, 2025, 261
[48]   Comparative study on thermal performance of horizontal ground source heat pump systems with Dirichlet and Robin boundary conditions on ground surface [J].
Zhou, Kun ;
Mao, Jinfeng ;
Li, Yong ;
Hua, Zhang .
ENERGY CONVERSION AND MANAGEMENT, 2020, 225
[49]   Heating load, heating load density and COP optimisations for an endoreversible variable temperature heat reservoir air heat pump [J].
Bi, Y. H. ;
Chen, L. G. ;
Sun, F. R. .
JOURNAL OF THE ENERGY INSTITUTE, 2009, 82 (01) :43-47
[50]   Thermal and energy performance assessment of a thermoelectric heat pump integrated in an adiabatic box [J].
Ibanez-Puy, Elia ;
Martin-Gomez, Cesar ;
Bermejo-Busto, Javier ;
Zuazua-Ros, Amaia .
APPLIED ENERGY, 2018, 228 :681-688