Three-heat-reservoir thermal Brownian heat pump and its performance limits

被引:1
作者
Chen, Lingen [1 ,2 ,3 ]
Qi, Congzheng [1 ,2 ,3 ]
Ge, Yanlin [1 ,2 ,3 ]
Feng, Huijun [1 ,2 ,3 ]
机构
[1] Inst Thermal Sci & Power Engn, Wuhan Inst Technol, Wuhan 430205, Peoples R China
[2] Hubei Prov Engn Technol Res Ctr Green Chem Equipme, Wuhan 430205, Peoples R China
[3] Wuhan Inst Technol, Sch Mech & Elect Engn, Wuhan 430205, Peoples R China
基金
中国国家自然科学基金;
关键词
Non -equilibrium thermodynamics; Three -heat -reservoir heat pump; Thermal Brownian motor; Heating load; Optimal performance; COP; OF-THE-ART; MAXIMUM POWER; EFFICIENCY; TECHNOLOGIES; OPTIMIZATION; MODEL;
D O I
10.1016/j.csite.2024.104224
中图分类号
O414.1 [热力学];
学科分类号
摘要
Three -heat -reservoir (THR) heat pump has the originality of using low-grade heat to achieve pumping heat, and it can recycle waste heat and reduce environmental pollution effectively. Based on the research ideas of macro THR heat pumps and micro three -terminal thermoelectric devices, this paper proposes a THR thermal Brownian heat pump cycle model. This cycle is driven by low-grade "heat" to work, and it may be seen as a combined cycle consisting of a two -reservoir thermal Brownian heat pump and a two -reservoir thermal Brownian engine. Using non equilibrium thermodynamics, expressions for heating load and coefficient of performance (COP) are derived. The coupling relation between external forces of two motors is obtained by solving the heat balance equations, and cycle performance is further obtained. The maximal heating load is obtained by optimizing barrier height, and the lower limit of COP is also given. Results show that the THR thermal Brownian heat pump can achieve pumping heat by using low-grade "heat". The internal parameters affect the coupling between two -heat -reservoir thermal Brownian engine and two -heat -reservoir thermal Brownian heat pump, which determines cycle performance directly. The curve of heating load about COP presents a parabolic -like shape, and an optimal COP exists to maximize heating load.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Effects of heat reservoir temperatures on the performance of thermoelectric heat pump driven by thermoelectric generator
    Meng, Fankai
    Chen, Lingen
    Sun, Fengrui
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2010, 5 (04) : 273 - 282
  • [22] Model of a total momentum filtered energy selective electron heat pump affected by heat leakage and its performance characteristics
    Chen, Lingen
    Ding, Zemin
    Sun, Fengrui
    ENERGY, 2011, 36 (07) : 4011 - 4018
  • [23] Investigations of the performance of a heat pump with internal heat exchanger
    Róbert Sánta
    Journal of Thermal Analysis and Calorimetry, 2022, 147 : 8499 - 8508
  • [24] Investigations of the performance of a heat pump with internal heat exchanger
    Santa, Robert
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2022, 147 (15) : 8499 - 8508
  • [25] Effect of heat transfer on the performance of a thermoelectric heat pump driven by a thermoelectric generator
    Chen, Lingen
    Meng, Fankai
    Sun, Fengrui
    REVISTA MEXICANA DE FISICA, 2009, 55 (04) : 282 - 291
  • [26] Performance study of heat-pipe solar photovoltaic/thermal heat pump system
    Chen, Hongbing
    Zhang, Lei
    Jie, Pengfei
    Xiong, Yaxuan
    Xu, Peng
    Zhai, Huixing
    APPLIED ENERGY, 2017, 190 : 960 - 980
  • [27] Thermal Brownian heat engine with external and internal irreversibilities
    Chen, Lingen
    Qi, Congzheng
    Ge, Yanlin
    Feng, Huijun
    ENERGY, 2022, 255
  • [28] Thermodynamic characteristics of a Brownian heat pump in a spatially periodic temperature field
    ZeMin Ding
    LinGen Chen
    FengRui Sun
    Science China Physics, Mechanics and Astronomy, 2010, 53 : 876 - 885
  • [30] Effect of heat exchanger design on seasonal performance of heat pump systems
    Ishaque, Shehryar
    Siddiqui, Md Irfanul Haque
    Kim, Man-Hoe
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 151