Three-heat-reservoir thermal Brownian heat pump and its performance limits

被引:1
|
作者
Chen, Lingen [1 ,2 ,3 ]
Qi, Congzheng [1 ,2 ,3 ]
Ge, Yanlin [1 ,2 ,3 ]
Feng, Huijun [1 ,2 ,3 ]
机构
[1] Inst Thermal Sci & Power Engn, Wuhan Inst Technol, Wuhan 430205, Peoples R China
[2] Hubei Prov Engn Technol Res Ctr Green Chem Equipme, Wuhan 430205, Peoples R China
[3] Wuhan Inst Technol, Sch Mech & Elect Engn, Wuhan 430205, Peoples R China
基金
中国国家自然科学基金;
关键词
Non -equilibrium thermodynamics; Three -heat -reservoir heat pump; Thermal Brownian motor; Heating load; Optimal performance; COP; OF-THE-ART; MAXIMUM POWER; EFFICIENCY; TECHNOLOGIES; OPTIMIZATION; MODEL;
D O I
10.1016/j.csite.2024.104224
中图分类号
O414.1 [热力学];
学科分类号
摘要
Three -heat -reservoir (THR) heat pump has the originality of using low-grade heat to achieve pumping heat, and it can recycle waste heat and reduce environmental pollution effectively. Based on the research ideas of macro THR heat pumps and micro three -terminal thermoelectric devices, this paper proposes a THR thermal Brownian heat pump cycle model. This cycle is driven by low-grade "heat" to work, and it may be seen as a combined cycle consisting of a two -reservoir thermal Brownian heat pump and a two -reservoir thermal Brownian engine. Using non equilibrium thermodynamics, expressions for heating load and coefficient of performance (COP) are derived. The coupling relation between external forces of two motors is obtained by solving the heat balance equations, and cycle performance is further obtained. The maximal heating load is obtained by optimizing barrier height, and the lower limit of COP is also given. Results show that the THR thermal Brownian heat pump can achieve pumping heat by using low-grade "heat". The internal parameters affect the coupling between two -heat -reservoir thermal Brownian engine and two -heat -reservoir thermal Brownian heat pump, which determines cycle performance directly. The curve of heating load about COP presents a parabolic -like shape, and an optimal COP exists to maximize heating load.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Three-heat-reservoir thermal Brownian heat transformer and its performance limits
    Qi, Congzheng
    Chen, Lingen
    Ge, Yanlin
    Feng, Huijun
    PHYSICA A-STATISTICAL MECHANICS AND ITS APPLICATIONS, 2023, 622
  • [2] Three-heat-reservoir thermal Brownian refrigerator and its performance limits
    Congzheng Qi
    Lingen Chen
    Yanlin Ge
    Wenhao Yang
    Huijun Feng
    The European Physical Journal Plus, 137
  • [3] Three-heat-reservoir thermal Brownian refrigerator and its performance limits
    Qi, Congzheng
    Chen, Lingen
    Ge, Yanlin
    Yang, Wenhao
    Feng, Huijun
    EUROPEAN PHYSICAL JOURNAL PLUS, 2022, 137 (10):
  • [4] Heat transfer effect on the performance of three-heat-reservoir thermal Brownian refrigerator
    Qi, Congzheng
    Chen, Lingen
    Ge, Yanlin
    Feng, Huijun
    JOURNAL OF NON-EQUILIBRIUM THERMODYNAMICS, 2024, 49 (01) : 11 - 25
  • [5] Equivalent combined cycle modelling for three-heat-reservoir thermal Brownian heat pump with heat-transfer effect and its optimal performance
    Lingen CHEN
    Congzheng QI
    Yanlin GE
    Huijun FENG
    Science China(Technological Sciences), 2025, 68 (02) : 31 - 43
  • [6] Equivalent combined cycle modelling for three-heat-reservoir thermal Brownian heat pump with heat-transfer effect and its optimal performance
    Chen, Lingen
    Qi, Congzheng
    Ge, Yanlin
    Feng, Huijun
    SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2025, 68 (02)
  • [7] Maximum profit performance of a three-heat-reservoir heat pump
    Chen, LG
    Wu, C
    Sun, FR
    Cao, S
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1999, 23 (09) : 773 - 777
  • [8] Equivalent combined cycle modeling and performance optimization for a three-heat-reservoir thermal Brownian heat transformer with external heat-transfer
    Qi, Congzheng
    Chen, Lingen
    Ge, Yanlin
    Feng, Huijun
    ENERGY, 2024, 313
  • [9] Optimal coefficient of performance and heating load relationship of a three-heat-reservoir endoreversible heat pump
    Chen, LG
    Wu, C
    Sun, F
    ENERGY CONVERSION AND MANAGEMENT, 1997, 38 (08) : 727 - 733
  • [10] Performance analysis of solar three-heat-reservoir cooling systems
    Wu, C
    Chen, LG
    Sun, FR
    ENERGY CONVERSION AND MANAGEMENT, 1996, 37 (11) : 1671 - 1676