Investigation on Distortion Buckling Behavior of Cold-formed Thin-walled Steel Built-up Box-section Columns

被引:0
作者
Li Y. [1 ]
Zhou T. [1 ]
Ding J. [1 ]
Li C. [1 ]
Zhang X. [1 ]
机构
[1] School of Civil Engineering, Chang'an University, Xi'an
来源
Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences | 2021年 / 48卷 / 11期
基金
中国国家自然科学基金;
关键词
Built-up box-section columns; Calculation method; Cold-formed thin-wall steel; Critical buckling load; Distortional buckling;
D O I
10.16339/j.cnki.hdxbzkb.2021.07.005
中图分类号
学科分类号
摘要
In order to study the distortional buckling behavior of cold-formed steel(CFS) built-up box-section columns, firstly, 9 C-section columns, 9 U-section columns, and 21 built-up box-section columns composed of C-section and U-section were investigated by the axial compression tests and numerical simulation. The buckling characteristics and mechanical behaviors of the columns were investigated. On this basis, a set of hypothesis models were proposed to study the influence of screw spacing on the deformation, the ultimate capacity, and the relationship between the screw spacing and the half-wavelength(λc) of CFS built-up box-section columns. The results show that: 1) The number and half-wavelength of distortion buckling are different for the specimens with different screw spacing. 2) When the screw spacing is less than 0.9λc, the ultimate capacities of built-up box-section columns are greater than the sum of the ultimate capacities of C-section and U-section columns, that is, the splicing effect of 1+1>2. 3) When the screw spacing is greater than 0.9λc, the ultimate capacity of the built-up box-section column is gradually close to the sum of the ultimate capacities of the C-section and U-section columns, i.e. 1+1≈2. In order to calculate the ultimate capacities of CFS built-up box-section columns, an approach to predict the elastic critical load of distortion buckling was proposed based on the direct strength method(DSM) in American code, and then the calculated results were applied to the DSM to obtain the ultimate capacity of CFS built-up box-section columns. The results obtained from the calculation method are in good agreement with the experimental and numerical simulation results, which suggests the accuracy and applicability of the proposed method in this paper. © 2021, Editorial Department of Journal of Hunan University. All right reserved.
引用
收藏
页码:91 / 100
页数:9
相关论文
共 18 条
[1]  
LAU S C W, HANCOCK G J., Distortional buckling formulas for channel columns, Journal of Structural Engineering, 113, 5, pp. 1063-1078, (1987)
[2]  
KWON Y B, HANCOCK G J., Tests of cold-formed channels with local and distortional buckling, Journal of Structural Engineering, 118, 7, pp. 1786-1803, (1992)
[3]  
GUAN Y, ZHOU X H, SHI Y, Et al., Study on calculation method for in-plane stiffness and bearing capacity of thin-walled steel composite floor, Journal of Hunan University (Natural Sciences), 46, 9, pp. 31-43, (2019)
[4]  
YOUNG B, CHEN J., Design of cold-formed steel built-up closed sections with intermediate stiffeners, Journal of Structural Engineering, 134, 5, pp. 727-737, (2008)
[5]  
ZHANG J H, YOUNG B., Experimental investigation of cold-formed steel built-up closed section columns with web stiffeners, Journal of Constructional Steel Research, 147, pp. 380-392, (2018)
[6]  
AISI North American specification for the design of cold-formed steel structural members: AISIS100-16, pp. 7-8, (2007)
[7]  
LI Y Q, YAO X Y, SHEN Z Y, Et al., Load-carrying capacity of 550 MPa high-strength cold-formed thin-walled steel built-up box section columns, Building Structure, 41, 6, pp. 36-41, (2011)
[8]  
Technical specification for cold-formed thin-walled steel structures: GB50018-2002, pp. 19-20, (2002)
[9]  
YUAN T T., Experimental and theoretical research on bearing capacity of closed-section multi-limbs built-up cold-formed steel compression columns, pp. 1-91, (2010)
[10]  
LI F T., Study on the axial mechanical properties of cold-formed thin-walled steel built-up box-section columns, pp. 1-110, (2015)