Reduction of delivery pressure fluctuations in a gerotor pump

被引:1
|
作者
Nazir, Kamran [1 ]
Sohn, Chang Hyun [2 ]
机构
[1] Natl Univ Technol NUTECH, Dept Mech Engn, Islamabad 44000, Pakistan
[2] Kyungpook Natl Univ, Sch Mech Engn, Daegu 702701, South Korea
基金
新加坡国家研究基金会;
关键词
CFD; Gerotor pump; Noise reduction; Port shape; Pressure oscillations; Vibrations; DESIGN; PORT;
D O I
10.1007/s12206-024-0713-9
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Generated rotor (gerotor) pumps have commercial applications in oil supply pumps and compressors. Unfortunately, they produce an excessive amount of noise while in operation. The present study focuses on reducing the noise, which is caused due to pressure oscillations in the fluid, and vibration levels when a gerotor pump is in operation. Three-dimensional numerical simulations were performed on the gerotor pump using the dynamic mesh method. The flow field was simulated using the commercial software Ansys Fluent. The mesh motion was provided in the form of a user-defined function. Computational fluid dynamics analysis was performed for different combinations of delivery pipe length and diameter, and their effects on delivery pressure were analyzed. It is observed from numerical results that the pressure oscillations are reduced around 20 % by increasing volume of port or pipe region, which in turn reduces the noise levels. It is concluded that the pressure oscillations during the fluid flow are highly dependent on the volume of the delivery pipe.
引用
收藏
页码:4161 / 4166
页数:6
相关论文
共 50 条
  • [1] Design of port plate in gerotor pump for reduction of pressure pulsation
    Sang-Yeol Kim
    Yun-Joo Nam
    Myeong-Kwan Park
    Journal of Mechanical Science and Technology, 2006, 20 : 1626 - 1637
  • [2] Design of port plate in gerotor pump for reduction of pressure pulsation
    Kim, Sang-Yeol
    Nam, Yun-Joo
    Park, Myeong-Kwan
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2006, 20 (10) : 1626 - 1637
  • [3] Numerical Study on Cavitating Flow-Induced Pressure Fluctuations in a Gerotor Pump
    Zhou, Peijian
    Cui, Jiayi
    Xiao, Gang
    Xiang, Chun
    Dai, Jiacheng
    Zheng, Shuihua
    ENERGIES, 2023, 16 (21)
  • [4] Contact stress in a gerotor pump
    Gamez-Montero, PJ
    Codina, E
    FLUID POWER SYSTEMS AND TECHNOLOGY - 2003, 2003, : 65 - 71
  • [5] Design and experimental verification of a port plate in a gerotor pump to reduce pressure pulsation
    Hee-Jee Sung
    Hyung-Ki Min
    Yun-Joo Nam
    Myung-Kwan Park
    Journal of Mechanical Science and Technology, 2018, 32 : 671 - 678
  • [6] Design and experimental verification of a port plate in a gerotor pump to reduce pressure pulsation
    Sung, Hee-Jee
    Min, Hyung-Ki
    Nam, Yun-Joo
    Park, Myung-Kwan
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2018, 32 (02) : 671 - 678
  • [7] Research on Pressure Pulsation Characteristics of Gerotor Pump for Active Vibration Damping System
    Cao, Wenbin
    Liu, Yinshui
    Dong, Jie
    Niu, Zhuang
    Shi, Youcheng
    IEEE ACCESS, 2019, 7 : 116567 - 116577
  • [8] Influence of rotor profile geometry on the performance of an original low-pressure gerotor pump
    Jacazio, Giovanni
    De Martin, Andrea
    MECHANISM AND MACHINE THEORY, 2016, 100 : 296 - 312
  • [9] Variable displacement gerotor pump design
    Tay, Yong Fong
    Cole, Jack H.
    American Society of Mechanical Engineers, The Fluid Power and Systems Technology Division (Publication) FPST, 1997, 4 : 93 - 98
  • [10] CFD modelling of the flow in a gerotor pump
    Iudicello, F
    Mitchell, D
    POWER TRANSMISSION AND MOTION CONTROL, 2002, : 53 - 64