New fault line selection scheme for four-circuit transmission lines on same tower

被引:0
|
作者
Yu Z. [1 ]
Bi J. [1 ]
Guo P. [2 ]
Wang X. [1 ]
Chen Q. [2 ]
机构
[1] School of Electrical Engineering Automation, Jiangxi University of Science and Technology, Ganzhou
[2] Guodian Nanjing Automation Co., Ltd., Nanjing
关键词
Fault line selection; Four-circuit lines on same tower; Parameter asymmetry; Phase-mode transformation; Simulation;
D O I
10.16081/j.epae.201909026
中图分类号
学科分类号
摘要
Starting with the four-circuit transmission lines on same tower with parameter asymmetry, combined with the characteristics of interline and interphase electromagnetic coupling in the four-circuit transmission lines, a suitable phase-mode transformation matrix is derived to decouple the impedance of each circuit line. The correctness of the decoupling method is proved by simulation and comparison. Based on the relationship between the decoupled independent modules, four parameters, i.e. K1, K2, K3 and K4 are defined. According to the different values of these four parameters in different circuit faults, a new fault line selection criterion is constructed. A large number of simulative data on PSCAD/EMTDC show that the proposed fault line selection scheme is fast, simple, reliable and unaffected by fault distance, transition resistance, load current and system operation mode. © 2019, Electric Power Automation Equipment Press. All right reserved.
引用
收藏
页码:127 / 132
页数:5
相关论文
共 14 条
  • [1] Wang Y., Yu M., Zhang L., Short circuit fault ana-lysis and protection scheme for looped DC microgrid, Electric Power Automation Equipment, 37, 2, pp. 7-14, (2017)
  • [2] Zheng T., Zhang J., Wu D., Et al., Cross-voltage short-circuit calculation of mixed-voltage double-circuit lines partly on the same tower, Transactions of China Electrotechnical Society, 33, 11, pp. 2496-2507, (2018)
  • [3] Zhu K., Wang Y., Ni J., Application of active disturbance technology in faulty line selection of arc suppression coil grounding system, Electric Power Automation Equipment, 37, 10, pp. 189-196, (2017)
  • [4] Gao J., Cheng Q., Cheng Y., Et al., Faulty line selection method based on quantum genetic bistable system for distribution network, Electric Power Automation Equipment, 38, 5, pp. 164-170, (2018)
  • [5] Wang S., Zhao D., Shang L., Et al., Fault location algorithm for incomplete double-circuit transmission lines based on line segment parameters, Transactions of China Electrotechnical Society, 32, 10, pp. 261-270, (2017)
  • [6] Liu J., Fan C., Tai N., Novel transverse diffe-rential protection method for HVDC transmission line, High Voltage Engineering, 42, 7, pp. 2266-2274, (2016)
  • [7] Yu Z., Cheng M., Guo P., Et al., A new me-thod of fault line selection for teed circuits with 4-2-1 model, Water Resources Power, 32, 8, pp. 165-168, (2014)
  • [8] Guo P., Tai N., Yu Z., Et al., New single-line faulted selecting method for four-parallel transmission lines on the same tower based on loop flow component, Transactions of China Electrotechnical Society, 30, 24, pp. 206-214, (2015)
  • [9] Xu P., Wang G., Li H., Et al., Fault line selection for four-parallel lines on same tower based on circulation currents, Power System Protection and Control, 39, 3, pp. 78-83, (2011)
  • [10] Ren M., Tai N., Study on line selection for multi-loop line fault at same tower based on negative-sequence current, East China Electric Power, 38, 9, pp. 1370-1374, (2010)