Experimental evaluation of a heat exchanger for different configurations between internal and external flow

被引:0
作者
Ramirez-Dolores, C. [1 ]
Andaverde, J. [2 ]
Ordonez-Castillo, L. [3 ]
Wong-Loya, J. [4 ]
机构
[1] Univ Nacl Autonoma Mexico, Posgrad Ingn, Inst Energias Renovables, Priv Xochicalco S-N, Temixco 62580, Morelos, Mexico
[2] Univ Veracruzana, Fac Ciencias Quim, Coatzacoalcos 96538, Veracruz, Mexico
[3] Univ Nacl Autonoma Mexico, Licenciatura Ingn Energias Renovables, Inst Energias Renovables, Priv Xochicalco S-N, Temixco 62580, Morelos, Mexico
[4] Univ Nacl Autonoma Mexico, Inst Energias Renovables, Priv Xochicalco S-N, Temixco 62580, Morelos, Mexico
关键词
Fluid flow; Air-water heat exchanger; NTU-epsilon; Heat exchanger positions; THERMAL PERFORMANCE; NUMERICAL EVALUATION; AIR-QUALITY; EARTH; COMFORT; DESIGN; ENERGY; GROUNDWATER; BUILDINGS; EQUATION;
D O I
10.1007/s41939-024-00460-0
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In the present work, the determination of the thermal effectiveness and temperature of the air at the outlet of a scale prototype of a heat exchanger immersed in flowing water was developed experimentally. This depended on the position of the working fluid (air) and of the heat exchanger positioning configuration. The tested positions were parallel flow, quasi-parallel oblique, counterflow, quasi-counterflow oblique, and crossflow. The temperature of the air at the outlet of the heat exchanger and the thermal effectiveness are essential to determine the most convenient operating position of these systems, especially those related to shallow geothermal energy. The thermohydraulic aspects of the heat exchanger presented were evaluated, by the Number of Transfer Units-Effectiveness (NTU-epsilon) method, under conditions of water flow in a natural channel and air flow induced by a blower, the system was built from commercial copper pipe and temperature sensors were placed in both the exchanger and the water to record temperature changes. The results of this study indicate that when the exchanger is positioned in the oblique quasi-counterflow position and the oblique quasi-parallel position, it exhibits the lowest air outlet temperatures and highest thermal effectiveness, which is relevant for building cooling applications.
引用
收藏
页码:4117 / 4132
页数:16
相关论文
共 56 条
  • [1] A review on effect of geometrical, flow and soil properties on the performance of Earth air tunnel heat exchanger
    Agrawal, Kamal Kumar
    Das Agrawal, Ghanshyam
    Misra, Rohit
    Bhardwaj, Mayank
    Jamuwa, Doraj Kamal
    [J]. ENERGY AND BUILDINGS, 2018, 176 : 120 - 138
  • [2] Three-dimensional simulation of earth air heat exchanger for cooling application and its validation using an experimental test rig
    Ahmad, Saif Nawaz
    Prakash, Om
    [J]. HEAT AND MASS TRANSFER, 2023, 59 (07) : 1277 - 1292
  • [3] The cooling potential of earth-air heat exchangers for domestic buildings in a desert climate
    Al-Ajmi, F
    Loveday, DL
    Hanby, VI
    [J]. BUILDING AND ENVIRONMENT, 2006, 41 (03) : 235 - 244
  • [4] HEAT-TRANSFER IN TUBE BANKS UNDER CONDITIONS OF TURBULENT INCLINED FLOW
    ANTONOPOULOS, KA
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1985, 28 (09) : 1645 - 1656
  • [5] Energy poverty, health and education outcomes: Evidence from the developing world
    Banerjee, Rajabrata
    Mishra, Vinod
    Maruta, Admasu Asfaw
    [J]. ENERGY ECONOMICS, 2021, 101
  • [6] Energy saving method for improving thermal comfort and air quality in warm humid climates using isothermal high velocity ventilation
    Bayoumi, Mohannad
    [J]. RENEWABLE ENERGY, 2017, 114 : 502 - 512
  • [7] Numerical parametric study of a new earth-air heat exchanger configuration designed for hot and arid climates
    Benrachi, Naoufel
    Ouzzane, Mohamed
    Smaili, Arezki
    Lamarche, Louis
    Badache, Messaoud
    Maref, Wahid
    [J]. INTERNATIONAL JOURNAL OF GREEN ENERGY, 2020, 17 (02) : 115 - 126
  • [8] Numerical evaluation of the effects of groundwater flow on borehole heat exchanger arrays
    Choi, Jung Chan
    Park, Joonsang
    Lee, Seung Rae
    [J]. RENEWABLE ENERGY, 2013, 52 : 230 - 240
  • [9] CORRELATING EQUATION FOR FORCED-CONVECTION FROM GASES AND LIQUIDS TO A CIRCULAR-CYLINDER IN CROSS-FLOW
    CHURCHILL, SW
    BERNSTEIN, M
    [J]. JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1977, 99 (02): : 300 - 306
  • [10] A review of adaptive thermal comfort research since 1998
    de Dear, R.
    Xiong, J.
    Kim, J.
    Cao, B.
    [J]. ENERGY AND BUILDINGS, 2020, 214