EXERGY ANALYSIS OF TITANIUM DIOXIDE (TiO2) SUSPENDED WITH R290/R600 AS A SUBSTITUTE FOR R134A

被引:0
作者
Madyira, D. M. [1 ]
Babarinde, T. O. [1 ,2 ]
机构
[1] Univ Johannesburg, Dept Mech Engn Sci, Johannesburg, South Africa
[2] Univ Johannesburg, Proc Energy & Enviromental Technol Stn PEETS, Johannesburg, South Africa
关键词
COP; Exergy; R134a; R290; R600; REFRIGERATION SYSTEM; PHYSICAL-PROPERTIES; ENERGY EFFICIENCY; R600A; NANOREFRIGERANTS; NANOLUBRICANT; ALTERNATIVES; ENHANCEMENT; PERFORMANCE; REPLACEMENT;
D O I
10.24425/amm.2024.147814
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
Synthetic refrigerants are being phased out gradually in accordance with international environmental protection protocols because of global warming and ozone layer depletion. Adopting R290/R600 refrigerant, an environmentally friendly refrigerant, to replace R134a, a high global warming potential refrigerant, provides one of the solutions. In this study, exergy analysis of R134a and TiO2 suspended with lubricant and R290/R600 with a composition of 60% R290 and 40% R600 (60:40) was investigated in vapour compression system (VCRS) using R290/ R600 in TiO2 nanomixture lubricant and compared with R134a and R290/ R600 in pure lubricant. At the inlets and outlets, the main components of the VCRS are connected to temperature and pressure sensors to measure the inlet and outlet temperatures and pressures. The results obtained were used to analyses the exergy losses at various VCRS components (compressor, condenser, evaporator, expansion valve) were investigated to determine the refrigerator's total exergy destruction (E center dot xdest.Total) and efficiency (eta ex). The E center dot xdest.Total of R290/R600 in pure lubricant and R290/R600 TiO2 nanomixture lubricant was reduced by 26.9% and 42.3%, respectively, and system eta ex increased by 27.7% and 38.9% respectively when compared to R134a in the system. Hence, TiO2 suspended with R290/R600 is potential a substitute for R134a.
引用
收藏
页码:237 / 243
页数:7
相关论文
共 32 条
  • [1] A review on exergy analysis of vapor compression refrigeration system
    Ahamed, J. U.
    Saidur, R.
    Masjuki, H. H.
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2011, 15 (03) : 1593 - 1600
  • [2] The effect of temperature and particles concentration on the determination of thermo and physical properties of SWCNT-nanorefrigerant
    Alawi, Omer A.
    Sidik, Nor Azwadi Che
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2015, 67 : 8 - 13
  • [3] Potential of nanorefrigerant and nanolubricant on energy saving in refrigeration system - A review
    Azmi, W. H.
    Sharif, M. Z.
    Yusof, T. M.
    Mamat, Rizalman
    Redhwan, A. A. M.
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 69 : 415 - 428
  • [4] Performance evaluation of graphene-enhanced LPG in a vapour compression refrigeration system: An experimental approach
    Babarinde, T. O.
    Madyira, D. M.
    Mashinini, P. M.
    [J]. ENERGY REPORTS, 2022, 8 : 1226 - 1235
  • [5] Enhancing the energy efficiency of vapour compression refrigerator system using R600a with graphene nanolubricant
    Babarinde, T. O.
    Akinlabi, S. A.
    Madyira, D. M.
    Ekundayo, F. M.
    [J]. ENERGY REPORTS, 2020, 6 : 1 - 10
  • [6] Babarinde T. O., 2018, International Journal of Energy for a Clean Environment, V19, P37
  • [7] Babarinde T. O., 2018, IOP Conference Series: Materials Science and Engineering, V413, DOI 10.1088/1757-899X/413/1/012068
  • [8] Babarinde T.O., 2021, The Use of Hydrocarbon Refrigerants in Combating Ozone Depletion and Global Warming: A Review
  • [9] Babarinde T.O., 2020, Comparative study of energy performance of R600a / TiO 2 AND R600a / MWCNT nanolubricants in a vapor compression refrigeration system, V21, P317
  • [10] Bas A., 2022, Experimental investigation of R600a as a low GWP substitute to R134a in the closed-loop two-phase thermosyphon of the mini thermoelectric refrigerator 211, DOI [10.1016/j.applthermaleng.2022.118501, DOI 10.1016/J.APPLTHERMALENG.2022.118501]