The power of modern extraction techniques: A breakthrough in vitamin K extraction from human serum

被引:0
作者
Mrstna, Kristyna [1 ,2 ]
Turonova, Dorota [1 ,2 ]
Suwanvecho, Chaweewan [1 ,2 ]
Svec, Frantisek [1 ]
Krcmova, Lenka Kujovska [1 ,2 ,3 ]
机构
[1] Charles Univ Prague, Fac Pharm Hradec Kralove, Dept Analyt Chem, Akad Heyrovskeho 1203-8, Hradec Kralove 50005, Czech Republic
[2] Univ Hosp Hradec Kralove, Dept Clin Biochem & Diagnost, Sokolska 581, Hradec Kralove 50005, Czech Republic
[3] Akad Heyrovskeho 1203, Hradec Kralove 50005, Czech Republic
关键词
Phylloquinone; Menaquinone; Bioanalysis; Microextraction; UHPLC-MS/MS; FAT-SOLUBLE VITAMINS; HUMAN PLASMA; PHYLLOQUINONE; 2,3-EPOXIDE; HOMOLOGS; MS;
D O I
10.1016/j.microc.2024.110170
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
As a representative of the lipophilic vitamins, vitamin K is one of the most difficult vitamins to analyze. Even modern approaches using mass spectrometry detection cannot be carried out without multi-step, timeconsuming, economically, and ecologically demanding sample treatment. These findings suggest an opportunity to develop new modern trends that could shorten and simplify the whole procedure, whereby emphasizing the processing of a large number of samples with an additional focus on more environmentally friendly techniques. We selected and compared the main types of both, modern and conventional approaches for vitamin K analysis in human serum including liquid-liquid extraction and solid-phase extraction on the one hand, as well as supported liquid extraction, PhreeTM phospholipid removal plate, miniaturized liquid-liquid extraction, and dispersive pipette extraction on the other hand. The different techniques were compared from an analytical perspective, including parameters such as recovery, limits of detection, and matrix effects, as well as from a non-analytical perspective, including time consumption, cost effectiveness, and manual labor required to perform the procedure. The modern techniques seem to have great advantages. Our results indicate that the PhreeTM phospholipid removal plate, and the miniaturized version of the liquid-liquid extraction are the best techniques. This work was also carried out to provide a guide for the extraction of vitamin K while determining it using the liquid chromatography-mass spectrometry technique, which may improve sample handling and help to remove potential obstacles in the future.
引用
收藏
页数:10
相关论文
共 22 条
  • [1] A novel salting-out assisted extraction coupled with HPLC-fluorescence detection for trace determination of vitamin K homologues in human plasma
    Ahmed, Sameh
    Mahmoud, Ashraf M.
    [J]. TALANTA, 2015, 144 : 480 - 487
  • [2] Quantitation of vitamin K1 in serum using online SPE-LC-MS/MS and the challenges of working with vitamin K
    Andersen, Ida Boegh
    Brasen, Claus Lohman
    Madsen, Jonna Skov
    Schmedes, Anne
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1117 : 41 - 48
  • [3] Quantitative determination of plasma vitamin K1 by high-performance liquid chromatography coupled to isotope dilution tandem mass spectrometry
    Ducros, Veronique
    Pollicand, Mickael
    Laporte, Francois
    Favier, Alain
    [J]. ANALYTICAL BIOCHEMISTRY, 2010, 401 (01) : 7 - 14
  • [4] LC-MS/MS quantitative analysis of phylloquinone, menaquinone-4 and menaquinone-7 in the human serum of a healthy population
    Dunovska, Katerina
    Klapkova, Eva
    Sopko, Bruno
    Cepova, Jana
    Prusa, Richard
    [J]. PEERJ, 2019, 7
  • [5] Measurement of Deuterium-Labeled Phylloquinone in Plasma by High-Performance Liquid Chromatography/Mass Spectrometry
    Fu, Xueyan
    Peterson, James W.
    Hdeib, Mona
    Booth, Sarah L.
    Grusak, Michael A.
    Lichtenstein, Alice H.
    Dolnikowski, Gregory G.
    [J]. ANALYTICAL CHEMISTRY, 2009, 81 (13) : 5421 - 5425
  • [6] Rapid, high performance method for the determination of vitamin K1, menaquinone-4 and vitamin K1 2,3-epoxide in human serum and plasma using liquid chromatography-hybrid quadrupole linear ion trap mass spectrometry
    Gentili, Alessandra
    Cafolla, Arturo
    Gasperi, Tecla
    Bellante, Simona
    Caretti, Fulvia
    Curini, Roberta
    Fernandez, Virginia Perez
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2014, 1338 : 102 - 110
  • [7] Primary photoreactions of phylloquinone (vitamin K1) and plastoquinone-1 in solution
    Hangarter, MA
    Hörmann, A
    Kamdzhilov, Y
    Wirz, J
    [J]. PHOTOCHEMICAL & PHOTOBIOLOGICAL SCIENCES, 2003, 2 (05) : 524 - 535
  • [8] A simple, sensitive, and high-throughput LC-APCI-MS/MS method for simultaneous determination of vitamin K1, vitamin K1 2,3-epoxide in human plasma and its application to a clinical pharmacodynamic study of warfarin
    Hu, Kuan
    Li, Yan
    Ding, Ru
    Zhai, Yu
    Chen, Lin
    Qian, Wei
    Yang, Jin
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 159 : 82 - 91
  • [9] The LC-MS method for the simultaneous analysis of selected fat-soluble vitamins and their metabolites in serum samples obtained from pediatric patients with cystic fibrosis
    Konieczna, Lucyna
    Kazmierska, Katarzyna
    Roszkowska, Anna
    Szlagatys-Sidorkiewicz, Agnieszka
    Baczek, Tomasz
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2016, 124 : 374 - 381
  • [10] Comparison of high-performance liquid chromatography/tandem mass spectrometry and high-performance liquid chromatography/photo-diode array detection for the quantitation of carotenoids, retinyl esters, -tocopherol and phylloquinone in chylomicron-rich fractions of human plasma
    Kopec, Rachel E.
    Schweiggert, Ralf M.
    Riedl, Ken M.
    Carle, Reinhold
    Schwartz, Steven J.
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2013, 27 (12) : 1393 - 1402