Review of Testing and Qualification of Post-Installed Anchors under Seismic Actions for Structural Applications

被引:2
作者
Stehle, Erik Johannes [1 ]
Sharma, Akanshu [1 ]
机构
[1] Univ Stuttgart, Inst Construct Mat, D-70569 Stuttgart, Germany
来源
CIVILENG | 2021年 / 2卷 / 02期
关键词
post-installed anchors; earthquake; qualification; seismic demands; test procedures; assessment; performance-based design; REINFORCED-CONCRETE FRAMES; RETROFIT;
D O I
10.3390/civileng2020023
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
During earthquakes, buildings are subjected to loads well beyond their usual demands, resulting in high stresses in the structural components and additional inertial forces coming from the non-structural elements. When post-installed anchors are used to form the connection between non-structural or structural members and the primary reinforced concrete structure, these anchors are also subjected to high seismic demands. To determine whether a post-installed anchor is suitable for such applications, it is assessed for its performance under seismic demands. In this review paper, the current European approach for testing and qualification of post-installed anchors under seismic actions is reviewed and discussed in the context of structural applications where anchors are used to form the connection between structural members that participate in the load-transfer mechanism against seismic loads. The first part of this paper provides a description of the testing procedures and the criteria against which the anchor performance is assessed. The procedures and assessment criteria are discussed regarding the suitability in the case of the above-described structural applications. In the second part, the qualification of anchors under seismic actions is discussed in the light of an upcoming performance-based design approach for anchors. In such an approach, information on the displacement and hysteretic behavior of an anchor in a broader range of the load-displacement curve is of vital importance. Therefore, additional testing approaches might be required in order to supplement the information on anchor performance provided in the current testing procedures. One such testing approach for pulsating tension load is reported.
引用
收藏
页码:406 / 420
页数:15
相关论文
共 39 条
[1]  
ACI, 2007, ACI 355.4
[2]  
[Anonymous], 2013, Guide for Testing Reinforced Concrete Structural Elements under Slowly Applied Simulated Seismic Loads
[3]  
[Anonymous], 2007, Qualification of Post-Installed Mechanical Anchors in Concrete (ACI355.2-07) and Commentary
[4]   Spring modelling approach for evaluation and design of tension loaded anchor groups in case of concrete cone failure [J].
Bokor, Boglarka ;
Sharma, Akanshu ;
Hofmann, Jan .
ENGINEERING STRUCTURES, 2019, 197
[5]   Numerical Analysis of a Masonry Panel Reinforced with Pultruded FRP Frames [J].
Casalegno, C. ;
Russo, S. ;
Sciarretta, F. .
MECHANICS OF COMPOSITE MATERIALS, 2018, 54 (02) :207-220
[6]  
CEN (European Committee for Standardization), 2004, Eurocode 4-Design of composite steel and concrete structures-Part 1-1: General rules and rules for building
[7]  
DIN EN 1992-4/NA, 2019, DIN EN 1992-4/NA: 2019-04
[8]  
Dowell RK, 1998, ACI STRUCT J, V95, P607
[9]  
EAD 330232, 2016, EAD 330232-00-0601
[10]  
EAD 330499, 2017, EAD 330499-00-0601