Motion-resistant three-wavelength spatial frequency domain imaging system with ambient light suppression using an 8-tap CMOS image sensor

被引:2
作者
Feng, Yu [1 ]
Cao, Chen [2 ]
Shimada, Yuto [1 ]
Yasutomi, Keita [2 ]
Kawahito, Shoji [2 ]
Kennedy, Gordon T. [3 ]
Durkin, Anthony J. [3 ,4 ]
Kagawa, Keiichiro [2 ]
机构
[1] Shizuoka Univ, Grad Sch Integrated Sci & Technol, Hamamatsu, Japan
[2] Shizuoka Univ, Res Inst Elect, Hamamatsu, Japan
[3] Univ Calif Irvine, Beckman Laser Inst, Irvine, CA USA
[4] Univ Calif Irvine, Biomed Engn Dept, Irvine, CA USA
基金
美国国家卫生研究院;
关键词
spatial frequency domain imaging; diffuse optics; multispectral imaging; multi-tap complementary metal-oxide semiconductor image sensor; OPTICAL-PROPERTIES; TURBID MEDIA; PRINCIPLES; PRESSURE;
D O I
10.1117/1.JBO.29.1.016006
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Significance: We present a motion-resistant three-wavelength spatial frequency domain imaging (SFDI) system with ambient light suppression using an 8-tap complementary metal-oxide semiconductor (CMOS) image sensor (CIS) developed at Shizuoka University. The system addresses limitations in conventional SFDI systems, enabling reliable measurements in challenging imaging scenarios that are closer to real-world conditions. Aim: Our study demonstrates a three-wavelength SFDI system based on an 8-tap CIS. We demonstrate and evaluate the system's capability of mitigating motion artifacts and ambient light bias through tissue phantom reflectance experiments and in vivo volar forearm experiments. Approach: We incorporated the Hilbert transform to reduce the required number of projected patterns per wavelength from three to two per spatial frequency. The 8-tap image sensor has eight charge storage diodes per pixel; therefore, simultaneous image acquisition of eight images based on multi-exposure is possible. Taking advantage of this feature, the sensor simultaneously acquires images for planar illumination, sinusoidal pattern projection at three wavelengths, and ambient light. The ambient light bias is eliminated by subtracting the ambient light image from the others. Motion artifacts are suppressed by reducing the exposure and projection time for each pattern while maintaining sufficient signal levels by repeating the exposure. The system is compared to a conventional SFDI system in tissue phantom experiments and then in vivo measurements of human volar forearms. Results: The 8-tap image sensor-based SFDI system achieved an acquisition rate of 9.4 frame sets per second, with three repeated exposures during each accumulation period. The diffuse reflectance maps of three different tissue phantoms using the conventional SFDI system and the 8-tap image sensor-based SFDI system showed good agreement except for high scattering phantoms. For the in vivo volar forearm measurements, our system successfully measured total hemoglobin concentration, tissue oxygen saturation, and reduced scattering coefficient maps of the subject during motion (16.5 cm/s) and under ambient light (28.9 lx), exhibiting fewer motion artifacts compared with the conventional SFDI. Conclusions: We demonstrated the potential for motion-resistant three-wavelength SFDI system with ambient light suppression using an 8-tap CIS.
引用
收藏
页数:14
相关论文
共 32 条
[1]  
[Anonymous], 2022, IEEE S VLSI TECHN CI, P48
[2]   A Dual NIR-Band Lock-In Pixel CMOS Image Sensor With Device Optimizations for Remote Physiological Monitoring [J].
Cao, Chen ;
Dutta, Jaydeep Kumar ;
Hakamata, Masashi ;
Yasutomi, Keita ;
Kagawa, Keiichiro ;
Aoyama, Satoshi ;
Tsumura, Norimichi ;
Kawahito, Shoji .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 2021, 68 (04) :1688-1693
[3]   Cerebral blood flow is decoupled from blood pressure and linked to EEG bursting after resuscitation from cardiac arrest [J].
Crouzet, Christian ;
Wilson, Robert H. ;
Bazrafkan, Afsheen ;
Farahabadi, Maryam H. ;
Lee, Donald ;
Alcocer, Juan ;
Tromberg, Bruce J. ;
Choi, Bernard ;
Akbari, Yama .
BIOMEDICAL OPTICS EXPRESS, 2016, 7 (11) :4660-4673
[4]   Quantitation and mapping of tissue optical properties using modulated imaging [J].
Cuccia, David J. ;
Bevilacqua, Frederic ;
Durkin, Anthony J. ;
Ayers, Frederick R. ;
Tromberg, Bruce J. .
JOURNAL OF BIOMEDICAL OPTICS, 2009, 14 (02)
[5]   Modulated imaging: quantitative analysis and tomography of turbid media in the spatial-frequency domain [J].
Cuccia, DJ ;
Bevilacqua, F ;
Durkin, AJ ;
Tromberg, BJ .
OPTICS LETTERS, 2005, 30 (11) :1354-1356
[6]   Consensus statement of the Movement Disorder Society on tremor [J].
Deuschl, G ;
Bain, P ;
Brin, M .
MOVEMENT DISORDERS, 1998, 13 :2-23
[7]  
Feng Y., 2023, Proc. SPIE, V12376
[8]   Principles, techniques, and limitations of near infrared spectroscopy [J].
Ferrari, M ;
Mottola, L ;
Quaresima, V .
CANADIAN JOURNAL OF APPLIED PHYSIOLOGY-REVUE CANADIENNE DE PHYSIOLOGIE APPLIQUEE, 2004, 29 (04) :463-487
[9]   First-in-human pilot study of a spatial frequency domain oxygenation imaging system [J].
Gioux, Sylvain ;
Mazhar, Amaan ;
Lee, Bernard T. ;
Lin, Samuel J. ;
Tobias, Adam M. ;
Cuccia, David J. ;
Stockdale, Alan ;
Oketokoun, Rafiou ;
Ashitate, Yoshitomo ;
Kelly, Edward ;
Weinmann, Maxwell ;
Durr, Nicholas J. ;
Moffitt, Lorissa A. ;
Durkin, Anthony J. ;
Tromberg, Bruce J. ;
Frangioni, John V. .
JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (08)
[10]   A noninvasive method for monitoring respiratory rate of rats based on a microcantilever resonant humidity sensor [J].
Guan, Yangyang ;
Le, Xianhao ;
Hu, MingZhe ;
Liu, Weixin ;
Xie, Jin .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2019, 29 (12)