Clinical, functional, and radiological outcomes of robotic assisted versus conventional total hip arthroplasty: a systematic review and meta-analysis of randomized controlled trials

被引:3
|
作者
Ruangsomboon, Pakpoom [1 ,2 ,3 ]
Ruangsomboon, Onlak [2 ,4 ]
Osman, Khabab [1 ]
Pincus, Daniel [1 ,5 ,6 ]
Mundi, Raman [1 ,5 ]
Tomescu, Sebastian [1 ,5 ]
Ravi, Bheeshma [1 ,5 ,6 ]
Chaudhry, Harman [1 ,5 ]
机构
[1] Sunnybrook Hlth Sci Ctr, Div Orthopaed Surg, Toronto, ON, Canada
[2] Mahidol Univ, Siriraj Hosp, Fac Med, Bangkok, Thailand
[3] Univ Toronto, Inst Hlth Policy Management & Evaluat, Toronto, ON, Canada
[4] St Michaels Hosp, Unity Hlth Toronto, Li Ka Shing Knowledge Inst, Upstream Lab,MAP Ctr Urban Hlth Solut, Toronto, ON, Canada
[5] Univ Toronto, Dept Surg, Div Orthopaed Surg, Toronto, ON, Canada
[6] ICES, Toronto, ON, Canada
关键词
Robotic; RATHA; Hip; Arthroplasty; Systematic review; Meta-analysis; MANUAL IMPLANTATION; REPLACEMENT; STEM; LONG;
D O I
10.1007/s11701-024-01949-z
中图分类号
R61 [外科手术学];
学科分类号
摘要
This systematic review of randomized controlled trials (RCTs) aims to compare important clinical, functional, and radiological outcomes between robotic-assisted total hip arthroplasty (RATHA) and conventional total hip arthroplasty (COTHA) in patients with hip osteoarthritis. We identified published RCTs comparing RATHA with COTHA in Ovid MEDLINE, EMBASE, Scopus, and Cochrane Library. Two reviewers independently performed study screening, risk of bias assessment and data extraction. Main outcomes were major complications, revision, patient-reported outcome measures (PROMs), and radiological outcomes. We included 8 RCTs involving 1014 patients and 977 hips. There was no difference in major complication rate (Relative Risk (RR) 0.78; 95% Confidence Interval (CI) 0.22 to 2.74), revision rate (RR 1.33; 95%CI 0.08 to 22.74), and PROMs (standardized mean difference 0.01; 95%CI - 0.27 to 0.30) between RATHA and COTHA. RATHA resulted in little to no effects on femoral stem alignment (mean difference (MD) - 0.57 degree; 95%CI - 1.16 to 0.03) but yielded overall lower leg length discrepancy (MD - 4.04 mm; 95%CI - 7.08 to - 1.0) compared to COTHA. Most combined estimates had low certainty of evidence mainly due to risk of bias, inconsistency, and imprecision. Based on the current evidence, there is no important difference in clinical and functional outcomes between RATHA and COTHA. The trivial higher radiological accuracy was also unlikely to be clinically meaningful. Regardless, more robust evidence is needed to improve the quality and strength of the current evidence.PROSPERO registration: the protocol was registered in the PROSPERO database (CRD42023453294). All methods were carried out in accordance with relevant guidelines and regulations.
引用
收藏
页数:28
相关论文
共 50 条
  • [1] Clinical and radiological outcomes of robotic-assisted versus conventional total knee arthroplasty: a systematic review and meta-analysis of randomized controlled trials
    Ruangsomboon, Pakpoom
    Ruangsomboon, Onlak
    Pornrattanamaneewong, Chaturong
    Narkbunnam, Rapeepat
    Chareancholvanich, Keerati
    ACTA ORTHOPAEDICA, 2023, 94 : 60 - 79
  • [2] A comparison of radiological and clinical outcomes between robotic-assisted and conventional total hip arthroplasty: A meta-analysis
    Wang, Yuxiang
    Wang, Ruoyu
    Gong, Song
    Han, Lizhi
    Gong, Tianlun
    Yi, Yihu
    Feng, Yong
    Wang, Guohong
    Xu, Weihua
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2023, 19 (01)
  • [3] Robotic-assisted versus conventional total knee arthroplasty: a systematic review and meta-analysis of randomized controlled trials
    Alrajeb, Reda
    Zarti, Mohammed
    Shuia, Zakaria
    Alzobi, Osama
    Ahmed, Ghalib
    Elmhiregh, Aissam
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2024, 34 (03) : 1333 - 1343
  • [4] Clinical and Radiological Outcomes in Robotic-Assisted Total Knee Arthroplasty: A Systematic Review and Meta-Analysis
    Agarwal, Nikhil
    To, Kendrick
    McDonnell, Stephen
    Khan, Wasim
    JOURNAL OF ARTHROPLASTY, 2020, 35 (11) : 3393 - +
  • [5] Robotic-assisted compared with conventional total hip arthroplasty: systematic review and meta-analysis
    Chen, Xi
    Xiong, Jianping
    Wang, Peipei
    Zhu, Shibai
    Qi, Wenting
    Peng, Huiming
    Yu, Lingjia
    Qian, Wenwei
    POSTGRADUATE MEDICAL JOURNAL, 2018, 94 (1112) : 335 - 341
  • [6] Hip resurfacing versus total hip arthroplasty: a systematic review and meta-analysis of randomized clinical trials
    Za, Pierangelo
    Casciaro, Carlo
    Papalia, Giuseppe Francesco
    Parisi, Francesco Rosario
    Longo, Umile Giuseppe
    Falez, Francesco
    Papalia, Rocco
    INTERNATIONAL ORTHOPAEDICS, 2024, 48 (10) : 2589 - 2601
  • [7] Robotic-assisted versus conventional total knee arthroplasty: a systematic review and meta-analysis of alignment accuracy and clinical outcomes
    Mostafa, Omar
    Malik, Maymunah
    Qayum, Kaif
    Ishaq, Usman
    Khan, Abdul Muhaymin
    Wasim, Abdus Samee
    Alsoud, Zain
    Quraishi, Sohail
    ANNALS OF MEDICINE AND SURGERY, 2025, 87 (02): : 867 - 879
  • [8] POSTERIOR VERSUS ANTERIOR APPROACH TO TOTAL HIP ARTHROPLASTY: A SYSTEMATIC REVIEW AND META- ANALYSIS OF RANDOMIZED CONTROLLED TRIALS
    Fagotti, Lorenzo
    Falotico, Guilherme Guadagnini
    Maranho, Daniel Augusto
    Ayeni, Olufemi R.
    Ejnisman, Benno
    Cohen, Moises
    Astur, Diego Costa
    ACTA ORTOPEDICA BRASILEIRA, 2021, 29 (06): : 297 - 303
  • [9] Computer navigation in total hip arthroplasty: A meta-analysis of randomized controlled trials
    Xu, Ke
    Li, Yao-min
    Zhang, Hua-feng
    Wang, Chen-guang
    Xu, Yun-qiang
    Li, Zhi-jun
    INTERNATIONAL JOURNAL OF SURGERY, 2014, 12 (05) : 528 - 533
  • [10] Minimally invasive versus conventional exposure for total hip arthroplasty: a systematic review and meta-analysis of clinical and radiological outcomes
    Smith, Toby O.
    Blake, Vicky
    Hing, Caroline B.
    INTERNATIONAL ORTHOPAEDICS, 2011, 35 (02) : 173 - 184