Liquid Sloshing in Soil-Supported Multiple Cylindrical Tanks Equipped with Baffle under Horizontal Excitation

被引:1
作者
Sun, Ying [1 ]
Meng, Xun [2 ]
Zhang, Zhong [1 ]
Gu, Zhenyuan [1 ]
Wang, Jiadong [3 ]
Zhou, Ding [4 ]
机构
[1] Nantong Univ, Sch Transportat & Civil Engn, Nantong 226019, Peoples R China
[2] Yancheng Inst Technol, Coll Civil Engn, Yancheng 224051, Peoples R China
[3] Jiangsu Univ, Fac Civil Engn & Mech, Zhenjiang 212013, Peoples R China
[4] Nanjing Tech Univ, Coll Civil Engn, Nanjing 211816, Peoples R China
基金
中国国家自然科学基金;
关键词
multiple tanks; annular baffle; fluid-structure interaction; analytical model; soil-structure interaction; dynamic response; FOUNDATION; MODEL; CONTAINER;
D O I
10.3390/buildings14041029
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The dynamic behavior of liquid storage tanks is one of the research issues about fluid-structure interaction problems. The analysis errors of the dynamics of multiple adjacent tanks can exist if neglecting soil-tank interaction since tanks are typically supported on flexible soil. In the present paper, the dynamics of a group of baffled cylindrical storage tanks supported on a circular surface foundation and undergoing horizontal excitation are analytically examined. For upper multiple tank-liquid-baffle subsystems, accurate solutions to the velocity potential for liquid sloshing are acquired according to the subdomain partition technique. A theoretical model is utilized to portray the continuous sloshing of each tank. For the soil-foundation subsystem, a lumped-parameter model is used to characterize the impacts of soil on upper-tank structures using Chebyshev complex polynomials that present the fitting results of horizontal, rocking, and coupling impedance functions. Then, a model of the soil-foundation-tank-liquid-baffle system is constructed on the basis of the substructure approach. The present sloshing frequencies, sloshing height, and hydrodynamic shear as well as the moment under rigid/soft soil foundations are compared to the available exact results and the numerical results to prove the validity of the present model. The error of the maximum sloshing height between the present and the numerical solutions is within 5.27%; the solution efficiency of system dynamics from the present model is 40-50 times faster than that from the ADINA model. A detailed parameter analysis of the dynamic characteristics and earthquake responses of the coupling system is presented. The research novelty is that an equivalent analytical model is presented, and it allows for investigating the dynamics of soil-supported multiple cylindrical tanks with a baffle, providing acceptable accuracy and high calculation efficiency.
引用
收藏
页数:28
相关论文
共 44 条
[31]   Nested Lumped-Parameter Model for Foundation with Strongly Frequency-dependent Impedance [J].
Wang, Jue ;
Zhou, Ding ;
Liu, Weiqing ;
Wang, Shuguang .
JOURNAL OF EARTHQUAKE ENGINEERING, 2016, 20 (06) :975-991
[32]   Numerical Investigation of Shallow Liquid Sloshing in a Baffled Tank and the Associated Damping Effect by BM-MPS Method [J].
Wang, Lizhu ;
Xu, Min ;
Zhang, Qian .
JOURNAL OF MARINE SCIENCE AND ENGINEERING, 2021, 9 (10)
[33]   Evolution Process of Liquefied Natural Gas from Stratification to Rollover in Tanks of Coastal Engineering with the Influence of Baffle Structure [J].
Wang, Zhe ;
Han, Fenghui ;
Liu, Yuxiang ;
Li, Wenhua .
JOURNAL OF MARINE SCIENCE AND ENGINEERING, 2021, 9 (01) :1-16
[34]   Liquid sloshing in a baffled rectangular tank under irregular excitations [J].
Wang, Zi-Hao ;
Jiang, Sheng-Chao ;
Bai, Wei ;
Li, Jin-Xuan .
OCEAN ENGINEERING, 2023, 278
[35]   Nested lumped-parameter models for foundation vibrations [J].
Wu, WH ;
Lee, WH .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2004, 33 (09) :1051-1058
[36]   Development of a Water Supplement System for a Tuned Liquid Damper under Excitation [J].
Xiao, Congzhen ;
Wu, Zhenhong ;
Chen, Kai ;
Tang, Yi ;
Yan, Yalin .
BUILDINGS, 2023, 13 (05)
[37]   The Influence of Integral Water Tank on the Seismic Performance of Slender Structure: An Experimental Study [J].
Xu, Bing ;
Han, Zhenyu ;
Wang, Lang ;
Liu, Qin ;
Xu, Xueyuan ;
Chen, Huihui .
BUILDINGS, 2023, 13 (03)
[38]   A shaking table substructure testing method for the structural seismic evaluation considering soil-structure interactions [J].
Xu, Guoshan ;
Ding, Yong ;
Xu, Jingfeng ;
Chen, Yongsheng ;
Wu, Bin .
ADVANCES IN STRUCTURAL ENGINEERING, 2020, 23 (14) :3024-3036
[39]   Numerical study of porous material layer effects on mitigating sloshing in a membrane LNG tank [J].
Xue, Mi-An ;
Jiang, Zhouyu ;
Hu, Ya-An ;
Yuan, Xiaoli .
OCEAN ENGINEERING, 2020, 218
[40]   Violent transient sloshing-wave interaction with a baffle in a three-dimensional numerical tank [J].
Xue, Mi-An ;
Zheng, Jinhai ;
Lin, Pengzhi ;
Xiao, Zhong .
JOURNAL OF OCEAN UNIVERSITY OF CHINA, 2017, 16 (04) :661-673