Performance Enhancement of Single-Phase Immersion Liquid-Cooled Data Center Servers

被引:3
作者
Ge, Junlei [1 ]
Xia, Feifan [2 ]
Zhang, Chengbin [1 ]
Huang, Yongping [1 ]
机构
[1] Southeast Univ, Sch Energy & Environm, Nanjing 210096, Peoples R China
[2] Wuhan Digital Engn Res Inst, Wuhan 430205, Peoples R China
基金
国家重点研发计划;
关键词
single-phase; immersion liquid-cooled; performance enhancement; data center; COOLING TECHNOLOGY; SYSTEM; PIPE;
D O I
10.1007/s11630-024-2010-4
中图分类号
O414.1 [热力学];
学科分类号
摘要
As the promising cooling method for the next generation of data centers, the internal heat transport mechanism and enhancement mechanism of single-phase immersion liquid-cooled (SPILC) systems are not yet well understood. To address this, a steady-state three-dimensional numerical model is constructed herein to analyze flow and thermal transport capacities in servers using SPILC and traditional air-cooling methods. Moreover, this paper emphasizes the influence of component positioning, and underscores the benefits of optimizing coolant flow distribution using baffles. The results indicate that the SPILC system outperforms the traditional air-cooling approach at the same inlet Reynolds number (Re). When Re=10 000, the SPILC method reduces the maximum temperature by up to 70.13%, increases the average convective heat transfer coefficient by 287.5%, and provides better overall thermal uniformity in data center servers. Moreover, placing devices downstream of high-power components creates "thermal barriers" and degrades thermal transport for upstream devices due to increased flow resistance. Excessive spacing between high-power devices can lead to the formation of bypass channels, further deteriorating heat transfer. Additionally, the addition of baffles in the inlet section of SPILC systems effectively enhances heat dissipation performance. To maximize the heat dissipation capacity, minimizing bypass channels and optimizing the flow distribution of coolants are crucial.
引用
收藏
页码:1757 / 1772
页数:16
相关论文
共 50 条
[31]   Performance analysis on liquid-cooled battery thermal management for electric vehicles based on machine learning [J].
Tang, Xingwang ;
Guo, Qin ;
Li, Ming ;
Wei, Changhua ;
Pan, Zhiyao ;
Wang, Yongqiang .
JOURNAL OF POWER SOURCES, 2021, 494
[32]   Single-phase liquid friction factors in microchannels [J].
Steinke, Mark E. ;
Kandlikar, Satish G. .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2006, 45 (11) :1073-1083
[33]   Immersed jet impingement heat transfer for servers in immersion cooling data center: A parametric study [J].
Jin, Puhang ;
Zhang, Xue ;
Zhang, Xiaoteng ;
Tan, Zhiming ;
Xie, Gongnan .
APPLIED THERMAL ENGINEERING, 2025, 274
[34]   The Effect of Piezoelectric Transducer Location on Heat Transfer Enhancement of an Ultrasonic-Assisted Liquid-Cooled CPU Radiator [J].
Delouei, A. Amiri ;
Sajjadi, H. ;
Ahmadi, G. .
IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY-TRANSACTIONS OF MECHANICAL ENGINEERING, 2024, 48 (01) :239-252
[35]   Liquid immersion cooling technology with natural convection in data center [J].
Matsuoka, Morito ;
Matsuda, Kazuhiro ;
Kubo, Hideo .
PROCEEDINGS OF THE 2017 IEEE 6TH INTERNATIONAL CONFERENCE ON CLOUD NETWORKING (CLOUDNET), 2017, :101-107
[36]   Center-Tapped π-Type Single-Phase Cell [J].
Simonetti, Domingos S. L. ;
Yuan, Xibo .
2019 IEEE 15TH BRAZILIAN POWER ELECTRONICS CONFERENCE AND 5TH IEEE SOUTHERN POWER ELECTRONICS CONFERENCE (COBEP/SPEC), 2019,
[37]   Optimization of data-center immersion cooling using liquid air energy storage [J].
Liu, Chuanliang ;
Hao, Ning ;
Zhang, Tianbo ;
Wang, Dexuan ;
Li, Zhenya ;
Bian, Wenjie .
JOURNAL OF ENERGY STORAGE, 2024, 90
[38]   PERFORMANCE ENHANCEMENT OF SINGLE-PHASE SWITCHED-RELUCTANCE MOTOR BY DC LINK VOLTAGE BOOSTING [J].
CHAN, S ;
BOLTON, HR .
IEE PROCEEDINGS-B ELECTRIC POWER APPLICATIONS, 1993, 140 (05) :316-322
[39]   Design of a single-phase immersion cooling system through experimental and numerical analysis [J].
Cheng, Chin-Chi ;
Chang, Po-Chun ;
Li, Hsing-Chieh ;
Hsu, Fu-, I .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 160
[40]   Full-scale Two-phase Liquid Immersion Cooing Data Center System in Tropical Environment [J].
Wu, Chenlong ;
Tong, Wei ;
Kanbur, Bans Burak ;
Duan, Fei .
PROCEEDINGS OF THE 2019 EIGHTEENTH IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS (ITHERM 2019), 2019, :703-708