Radial Arterial Cannulation by Ultrasound-Guided Dynamic Needle-Tip Positioning Using the Short-Axis Out-of-Plane Approach Versus the Long-Axis In-Plane Approach: A Randomized Controlled Study

被引:2
作者
Mesa, Bharath Kumar [1 ]
Sinha, Mamta [1 ]
Kumar, Mayank [1 ]
Ramchandani, Sarita [1 ]
Dey, Chandan [2 ]
Agrawal, Nandkishore [1 ]
Khetarpal, Monica [1 ]
机构
[1] All India Inst Med Sci, Anesthesiol, Raipur, India
[2] All India Inst Med Sci, Emergency Med & Trauma, Raipur, India
关键词
first pass success; long axis approach; short axis approach; dynamic needle tip positioning; ultrasound; radial artery cannulation;
D O I
10.7759/cureus.54183
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Radial artery cannulation is a commonly performed invasive procedure for assessing a patient's hemodynamic status and collecting blood samples. Ultrasound guidance has shown benefits in improving the success rate of first -attempt cannulation. Two main approaches, short -axis out -of -plane (SAOOP) and long -axis in -plane (LAIP), are commonly used. A modified technique called dynamic needle -tip positioning (DNTP) using the short -axis out -of -plane approach has been reported to enhance arterial catheterization. This study aims to compare the first -attempt success rates of radial artery cannulation using the two techniques, DNTP versus LAIP, along with overall success rates, cannulation time, and number of attempts. Methods This prospective, randomized, controlled, clinical study was conducted after obtaining clearance from the Institute Ethics Committee of AIIMS, Raipur. Ninety-six patients between the ages of 18 and 50 years, undergoing elective surgery under general anesthesia, and required radial arterial cannulation were randomized and equally allocated into two groups as the LAIP and DNTP approaches. The first -pass success rate, time to achieve successful cannulation, number of attempts needed, overall success rate within five minutes, and potential complications, such as thrombosis, vasospasm, and hematoma, were recorded. Results A total of 96 patients were included, with 48 in the LAIP group and 48 in the DNTP group. The DNTP group showed statistically significant advantages over the LAIP group, with a higher first -pass success rate (97.9% vs. 83.3%; p = 0.014) and shorter time to achieve successful cannulation (9.29 +/- 3.79 vs. 26.16 +/- 20.22 seconds; p = 0.001). Conclusion The ultrasound -guided short -axis DNTP technique for radial artery cannulation demonstrated a significant advantage as compared to the LAIP technique. The DNTP technique resulted in higher first -attempt cannulation success and shorter cannulation time.
引用
收藏
页数:7
相关论文
共 15 条
[1]   Ultrasound-Guided Out-of-Plane Versus In-Plane Radial Artery Cannulation in Adult Cardiac Surgical Patients [J].
Arora, Nishant Ram ;
Maddali, Madan Mohan ;
Al-Sheheimi, Rashid Ahmed Rashid ;
Al-Mughairi, Hajer ;
Panchatcharam, Sathiya Murthi .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2021, 35 (01) :84-88
[2]   Ultrasound-guided radial arterial cannulation: long axis/in-plane versus short axis/out-of-plane approaches? [J].
Berk, Derya ;
Gurkan, Yavuz ;
Kus, Alparslan ;
Ulugol, Halim ;
Solak, Mine ;
Toker, Kamil .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2013, 27 (03) :319-324
[3]   Radial Artery Cannulation: A Comprehensive Review of Recent Anatomic and Physiologic Investigations [J].
Brzezinski, Marek ;
Luisetti, Thomas ;
London, Martin J. .
ANESTHESIA AND ANALGESIA, 2009, 109 (06) :1763-1781
[4]   Comparison between the long-axis in-plane and short-axis out-of-plane approaches for ultrasound-guided arterial cannulation: a meta-analysis and systematic review [J].
Cao, Lei ;
Tan, Yu-ting ;
Wei, Ting ;
Li, Hong .
BMC ANESTHESIOLOGY, 2023, 23 (01)
[5]  
Clemmesen L, 2012, Ultraschall Med, V33, pE321, DOI 10.1055/s-0032-1312824
[6]   Comparison of Ultrasound-Guided Versus Palpatory Method of Posterior Tibial Artery Cannulation: A Prospective Randomized Controlled Study [J].
Eda, Jhansi ;
Gupta, Priyanka ;
Kaushal, Ashutosh .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (12)
[7]   Ultrasound-Guided Dynamic Needle Tip Positioning Technique Versus Palpation Technique for Radial Arterial Cannulation in Adult Surgical Patients: A Randomized Controlled Trial [J].
Kiberenge, Roy K. ;
Ueda, Kenichi ;
Rosauer, Brett .
ANESTHESIA AND ANALGESIA, 2018, 126 (01) :120-126
[8]  
Kumar M., 2022, INDIAN J CLIN ANAEST, V9, P273, DOI DOI 10.18231/J.IJCA.2022.052
[9]   Use of ultrasound guidance in the insertion of radial artery catheters [J].
Levin, PD ;
Sheinin, O ;
Gozal, Y .
CRITICAL CARE MEDICINE, 2003, 31 (02) :481-484
[10]   "Modified Dynamic Needle Tip Positioning" Short-Axis, Out-of-Plane, Ultrasound-Guided Radial Artery Cannulation in Neonates: A Randomized Controlled Trial [J].
Liu, Lifei ;
Tan, Yanzhe ;
Li, Shangyingying ;
Tian, Jie .
ANESTHESIA AND ANALGESIA, 2019, 129 (01) :178-183