摘要
Objective: To determine anatomic relationships and variation of the round window membrane to bony surgical landmarks on computed tomography. Study design: Retrospective imaging review. Methods: 100 temporal bone images were evaluated. Direct measurements were obtained for membrane position. Vector distances and angulation from umbo and bony annulus were calculated from image viewer software coordinates. Results: The angle of round window membrane at junction with cochlear basal turn was (42.1 8.6)degrees. The membrane's position relative to plane of the facial nerve through facial recess was (14.7 +/- 5.2)degrees posterior from a reference line drawn through facial recess to carotid canal. Regarding transtympanic drug delivery, the round window membrane was directed 4.1 mm superiorly from the inferior annulus and 5.4 mm anteriorly from the posterior annulus. The round window membrane on average was angled superiorly from the inferior annulus (77.1 +/- 27.9)degrees and slightly anteriorly from the posterior annulus (19.1 +/- 11.1 degrees). The mean distance of round window membrane from umbo was 4 mm and posteriorly rotated 30 degrees clockwise from a perpendicular drawn from umbo to inferior annulus towards posterior annulus. Together, these measurements approximate the round window membrane in the tympanic membrane's posteroinferior quadrant. Conclusions: These radiologic measurements demonstrate normal variations seen in round window anatomy relative to facial recess approach and bony tympanic annulus, providing a baseline to assess round window insertion for cochlear implantation and outlines anatomic factors affecting transtympanic drug delivery. Copyright (c) 2020 Chinese Medical Association. Publishing services by Elsevier B.V. on behalf of KeAi Communications Co. Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:9 / 16
页数:8
相关论文
共 43 条
  • [11] The Relationship Between Cochleovestibular Orientation, Age, and Sensorineural Hearing Loss: Implications for Cochlear Implantation
    Formeister, Eric J.
    Campbell, Adam P.
    Choudhury, Baishakhi
    Huang, Benjamin
    Jewells, Valerie
    Adunka, Oliver F.
    [J]. ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2015, 124 (09) : 681 - 690
  • [12] Intratympanic dexamethasone for sudden sensorineural hearing loss after failure of systemic therapy
    Haynes, David S.
    O'Malley, Matthew
    Cohen, Seth
    Watford, Kenneth
    Labadie, Robert F.
    [J]. LARYNGOSCOPE, 2007, 117 (01) : 3 - 15
  • [13] Novel In Vivo Imaging Analysis of an Inner Ear Drug Delivery System in Mice: Comparison of Inner Ear Drug Concentrations over Time after Transtympanic and Systemic Injections
    Kanzaki, Sho
    Fujioka, Masato
    Yasuda, Akimasa
    Shibata, Shinsuke
    Nakamura, Masaya
    Okano, Hirotaka James
    Ogawa, Kaoru
    Okano, Hideyuki
    [J]. PLOS ONE, 2012, 7 (12):
  • [14] Kashio A, 2015, OTOL NEUROTOL, V36, pE18, DOI 10.1097/MAO.0000000000000644
  • [15] Accuracy and Reliability of Length Measurements on Three-Dimensional Computed Tomography Using Open-Source OsiriX Software
    Kim, Gihyeon
    Jung, Ho-Joong
    Lee, Han-Jun
    Lee, Jae-Sung
    Koo, Seungbum
    Chang, Seung-Hwan
    [J]. JOURNAL OF DIGITAL IMAGING, 2012, 25 (04) : 486 - 491
  • [16] Transcanal Approach for Implantation of a Cochlear Nerve Electrode Array
    Kiumehr, Saman
    Mahboubi, Hossein
    Middlebrooks, John C.
    Djalilian, Hamid R.
    [J]. LARYNGOSCOPE, 2013, 123 (05) : 1261 - 1265
  • [17] Preliminary Results With Image-guided Cochlear Implant Insertion Techniques
    Labadie, Robert F.
    Noble, Jack H.
    [J]. OTOLOGY & NEUROTOLOGY, 2018, 39 (07) : 922 - 928
  • [18] Minimally Invasive Image-Guided Cochlear Implantation Surgery: First Report of Clinical Implementation
    Labadie, Robert F.
    Balachandran, Ramya
    Noble, Jack H.
    Blachon, Gregoire S.
    Mitchell, Jason E.
    Reda, Fitsum A.
    Dawant, Benoit M.
    Fitzpatrick, J. Michael
    [J]. LARYNGOSCOPE, 2014, 124 (08) : 1915 - 1922
  • [19] Evaluation of round window accessibility to cochlear implant insertion
    Leong, Annabelle C.
    Jiang, Dan
    Agger, Andreas
    Fitzgerald-O'Connor, Alec
    [J]. EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2013, 270 (04) : 1237 - 1242
  • [20] Multiplanar Reformations in the Measurement of Renal Length on CT: Is It Plain Which Plane to Use?
    Lisanti, Christopher J.
    Oettel, David J.
    Reiter, Michael J.
    Schwope, Ryan B.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (04) : 797 - 801