Age-related changes of intraocular pressure in Dutch belted rabbits

被引:1
作者
Shin, Young In [1 ,2 ]
Kim, Young Kook [1 ,3 ]
Jeoung, Jin Wook [1 ,3 ]
Park, Ki Ho [1 ,3 ]
机构
[1] Seoul Natl Univ, Coll Med, Dept Ophthalmol, Seoul 03080, South Korea
[2] Gachon Univ Gil Hosp, Dept Ophthalmol, Inchon, South Korea
[3] Seoul Natl Univ Hosp, Dept Ophthalmol, Seoul, South Korea
来源
SCIENTIFIC REPORTS | 2024年 / 14卷 / 01期
关键词
Ophthalmology; Ophthalmic tests; Intraocular pressure; Glaucoma; Tonometry; Dutch belted rabbits; CIRCADIAN-RHYTHM;
D O I
10.1038/s41598-024-62097-w
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This study investigated intraocular pressure (IOP) in Dutch belted rabbits using two different tonometers, rebound tonometry (TonoVet Plus; TVP) and a Tonopen (Tono-Pen AVIA Vet; TPA). Post-pubescent male Dutch belted rabbits aged 36 weeks (n = 10 animals) were used in the study. IOP measurements were conducted every 2 weeks for 22 weeks using TVP and TPA on both eyes of each rabbit. The average IOP measurements were compared by the paired Student's t-test. Pairwise Pearson's correlation coefficients and Bland-Altman statistics were used. The overall mean IOP measured with TPA was significantly higher than that with TVP (23.5 +/- 4.9 vs. 21.8 +/- 2.4 mmHg for the right eyes; P = 0.045, and 23.0 +/- 4.7 vs. 21.5 +/- 2.4 mmHg for the left eyes; P = 0.047). Both tonometers tended to show increased IOP readings with age, and positive correlations between IOP and age were observed with both TPA (r = 0.95, P < 0.001 for right eyes; r = 0.95, P < 0.001 for left eyes) and TVP (r = 0.91, P < 0.001 for right eyes; r = 0.64, P = 0.024 for left eyes). The average bias calculated by subtracting TPA from TVP was - 1.60 (95% confidence intervals - 1.927, - 1.281) mmHg. IOP in post-pubescent Dutch belted rabbits tended to increase with age throughout the 22 week study.
引用
收藏
页数:6
相关论文
共 21 条
[1]   Animal Models of Glaucoma [J].
Bouhenni, Rachida A. ;
Dunmire, Jeffrey ;
Sewell, Abby ;
Edward, Deepak P. .
JOURNAL OF BIOMEDICINE AND BIOTECHNOLOGY, 2012,
[2]   Comparison of Tono-Pen Avia and Handheld Applanation Tonometry in Primary Congenital Glaucoma [J].
Cronemberger, Sebastiao ;
Veloso, Artur W. .
JOURNAL OF GLAUCOMA, 2021, 30 (05) :E227-E230
[3]   Experimental Models of Glaucoma: A Powerful Translational Tool for the Future Development of New Therapies for Glaucoma in Humans-A Review of the Literature [J].
Evangelho, Karine ;
Mastronardi, Claudio A. ;
de-la-Torre, Alejandra .
MEDICINA-LITHUANIA, 2019, 55 (06)
[4]   Comparison of the use of new handheld tonometers and established applanation tonometers in dogs [J].
Görig, C ;
Coenen, RTI ;
Stades, FC ;
Djajadiningrat-Laanen, SC ;
Boevé, MH .
AMERICAN JOURNAL OF VETERINARY RESEARCH, 2006, 67 (01) :134-144
[5]   CERVICAL GANGLIONECTOMY ALTERS THE CIRCADIAN-RHYTHM OF INTRAOCULAR-PRESSURE IN NEW-ZEALAND WHITE-RABBITS [J].
GREGORY, DS ;
AVIADO, DG ;
SEARS, ML .
CURRENT EYE RESEARCH, 1985, 4 (12) :1273-1279
[6]   Consequences of Puberty on Efficacy of Intraocular Pressure-Lowering Drugs in Male Dutch-Belted Rabbits [J].
Hays, Cassandra L. ;
Okafor, Kingsley C. ;
Fan, Shan ;
High, Robin ;
Singh, Dhirendra P. ;
Toris, Carol B. .
JOURNAL OF OCULAR PHARMACOLOGY AND THERAPEUTICS, 2018, 34 (1-2) :76-84
[7]  
KLEIN BEK, 1992, INVEST OPHTH VIS SCI, V33, P2224
[8]   Distribution of intraocular pressure - The Barbados Eye Study [J].
Leske, MC ;
Connell, AMS ;
Wu, SY ;
Hyman, L ;
Schachat, AP .
ARCHIVES OF OPHTHALMOLOGY, 1997, 115 (08) :1051-1057
[9]   Accuracy of intraocular pressure measurements in New Zealand white rabbits [J].
Lim, KS ;
Wickremasinghe, SS ;
Cordeiro, MF ;
Bunce, C ;
Khaw, PT .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (07) :2419-2423
[10]   Repeatability, reproducibility and agreement of intraocular pressure measurement in rabbits by the TonoVet and Tono-Pen [J].
Ma, Di ;
Chen, Chong-Bo ;
Liang, Jiajian ;
Lu, Zhihao ;
Chen, Haoyu ;
Zhang, Mingzhi .
SCIENTIFIC REPORTS, 2016, 6