Multi-step building energy model calibration process based on measured data

被引:0
|
作者
Pachano, José Eduardo [1 ]
Bandera, Carlos Fernández [1 ]
机构
[1] School of Architecture, University of Navarra, Pamplona,31009, Spain
基金
欧盟地平线“2020”;
关键词
Buildings - HVAC - Regulatory compliance - Software testing - Radiators - Retrofitting - Energy efficiency - Pumps - Space heating - Benchmarking - Heat pump systems - Boilers - Energy utilization;
D O I
暂无
中图分类号
学科分类号
摘要
Building energy models are a key element in regulatory compliance calculations. These energy performance calculations often do not accurately reflect actual operating conditions. Therefore, evaluation of energy performance comparing actual energy use of a building with the outcome of dynamic simulation models can be misleading, this difference is also known as the energy performance gap. The reduction of the gap is an important task aimed to provide confidence in the use of models for evaluation of energy efficiency. This paper is focused on reducing the technical issues (e.g. poorly adjusted thermal parameters in the envelope, inefficient boiler operator or lack of adjustment in parameters of heat pumps, baseboard radiators or air handling units) which are one of the main causes of the energy performance gap. The application of a multi-step, optimization-based, calibration methodology performed in a white-box simulation environment (EnergyPlus) using three months of ten minute time-step data to adjust HVAC parameter values with a genetic algorithm software (Jeplus) is validated on a real test site. Resulting in a BEM that fits the building's hourly performance benchmark into international standards on three key levels: indoor temperature by Thermal Zone (TZ), heat production and electric consumption from heat pumps, which comprise all the components of a building energy model. A batch of 1500 h of heating operation, obtained from the building management system, has been used to calibrate the model. The results complied with the requirements of the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) Guideline 14–2002 at hourly interval, with NMBE ⩽±10%,Cv(RMSE) ⩽30% and R2 ⩾75% and with the International Performance Measurement and Verification Protocol (EVO) for Cv(RMSE) ⩽20% and R2 ⩾75% in the three aforementioned levels, which can be considered a step forward in the area of calibrating white box models. In addition, to prove the strength and robustness of the results, the model has been checked in a long testing and independent period of 2.500 h of heating operations with the same level of compliance. The demonstrator is the library of a school located in Denmark. The HVAC system is composed of four air–water heat pumps that deliver heating to the whole compound with the backup support of a gas boiler. The library is heated with baseboard radiators system with the support of an air handling unit used for ventilation purposes. © 2021 Universidad de Navarra
引用
收藏
相关论文
共 50 条
  • [1] Multi-step building energy model calibration process based on measured data
    Pachano, Jose Eduardo
    Bandera, Carlos Fernandez
    ENERGY AND BUILDINGS, 2021, 252
  • [2] Calibration of a Building Energy Model Using Measured Data
    Monfet, Danielle
    Zmeureanu, Radu
    Charneux, Roland
    Lemire, Nicolas
    ASHRAE TRANSACTIONS 2009, VOL 115, PT 1, 2009, 115 : 348 - +
  • [3] Data-based control of a multi-step forming process
    Schulte, R.
    Frey, P.
    Hildenbrand, P.
    Vogel, M.
    Betz, C.
    Lechner, M.
    Merklein, M.
    36TH IDDRG CONFERENCE - MATERIALS MODELLING AND TESTING FOR SHEET METAL FORMING, 2017, 896
  • [4] Two-stage multi-step energy model calibration of the cooling systems of a large-space commercial building
    Pachano, Jose Eduardo
    Iglesias, Maria Fernandez-Vigil
    Saiz, Juan Carlos
    Bandera, Carlos Fernandez
    APPLIED THERMAL ENGINEERING, 2023, 230
  • [5] The multi-step process of building TB/HIV collaboration in Cambodia
    Eang, Mao Tan
    Vun, Mean Chhi
    Eam, Khun Kim
    Sovannarith, Samreth
    Sopheap, Seng
    Bora, Ngauv
    Yadav, Rajendra
    Fujita, Masami
    Tomas, Bernard
    Ghidinelli, Massimo
    van Maaren, Pieter
    Wells, William A.
    HEALTH RESEARCH POLICY AND SYSTEMS, 2012, 10
  • [6] The multi-step process of building TB/HIV collaboration in Cambodia
    Mao Tan Eang
    Mean Chhi Vun
    Khun Kim Eam
    Samreth Sovannarith
    Seng Sopheap
    Ngauv Bora
    Rajendra Yadav
    Masami Fujita
    Bernard Tomas
    Massimo Ghidinelli
    Pieter van Maaren
    William A Wells
    Health Research Policy and Systems, 10
  • [7] An automated multi-step calibration procedure for a river system model
    Hughes, J. D.
    Dutta, D.
    Vaze, J.
    Kim, S. S. H.
    Podger, G.
    ENVIRONMENTAL MODELLING & SOFTWARE, 2014, 51 : 173 - 183
  • [8] Impact of measured data frequency on commercial building energy model calibration for retrofit analysis
    Derakhti, Mohammad
    O'Brien, William
    Bucking, Scott
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2022, 28 (05) : 628 - 644
  • [9] Multi-Step Forecasting for Lighting and Equipment Energy Consumption in Office Building Based on Deep Learning
    Zhou X.
    Lei S.
    Yan J.
    Huanan Ligong Daxue Xuebao/Journal of South China University of Technology (Natural Science), 2020, 48 (10): : 19 - 29
  • [10] Iterative multi-step explicit camera calibration
    Batista, J
    Araujo, H
    de Almeida, AT
    SIXTH INTERNATIONAL CONFERENCE ON COMPUTER VISION, 1998, : 709 - 714