Development of Magnetic Solid Phase Micro-Extraction (MSPE) Method for the Extraction and Preconcentration of the Selected β-Blockers in the Environmental Wastewaters

被引:2
|
作者
Waleng, Ngwako Joseas [1 ,2 ]
Selahle, Shirley Kholofelo [1 ,2 ]
Mpupa, Anele [1 ,2 ]
Zhang, Yongjun [3 ]
Nomngongo, Philiswa Nosizo [1 ,2 ,4 ]
机构
[1] Univ Johannesburg, Dept Chem Sci, Doornfontein Campus,POB 17011, ZA-2028 Johannesburg, South Africa
[2] Univ Johannesburg, Dept Sci & Innovat, Natl Res Fdn South African Res Chair Initiat DSI N, ZA-2028 Doornfontein, South Africa
[3] Nanjing Tech Univ, Sch Environm Sci & Engn, Puzhu Nan Lu 30, Nanjing 211800, Peoples R China
[4] Univ Johannesburg, DSI Mintek Nanotechnol Innovat Ctr, ZA-2028 Doornfontein, South Africa
来源
CHEMISTRY AFRICA-A JOURNAL OF THE TUNISIAN CHEMICAL SOCIETY | 2024年 / 7卷 / 06期
关键词
Solid-phase Extraction; Metal Organic Frameworks; beta-blockers; Central Composite Design; ADSORPTION PERFORMANCE; MICROEXTRACTION; WATERS; UV; BETA(2)-AGONISTS; PHARMACEUTICALS; DEGRADATION; SORBENTS; DRUGS; OXIDE;
D O I
10.1007/s42250-024-00969-4
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Emerging organic pollutants s have always been the greatest environmental concern due to their ubiquity and distinguished adverse effects. These are mostly water-bone pollutants flagged as endocrine disruptors and can greatly inconvenience the ecosystem. Among others, beta-blockers have also been detected in the environment at various concentrations that threaten the well-being of humans and animals. In this work, NH2-MIL-101(Cr) doped magnetic nanoparticles nanocomposite was successfully synthesised and characterised using analytical techniques such as X-ray diffraction spectroscopy (XRD), scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), Brunauer-Emmett-Teller (BET) and transmission electron microscopy (TEM). The Fe3O4@NH2-MIL-101(Cr) was then used as an adsorbent to extract the selected beta-blockers in the environmental wastewater. The selected beta-blockers were quantified using a high-performance liquid chromatography-diode array detector (HPLC-DAD). Parameters affecting the extraction were screened and optimised using fractional factorial design (FFD) and central composite design (CCD), respectively. Under optimum conditions, the LODs were 0.057 and 0.065 mu g L- 1, and LOQs were 0.19 and 0.22 mu g L- 1 for acebutolol (ACE) and metoprolol (MET), respectively. The calibration curve exhibited the linearity range of 0.2-1200 mu g L- 1 with correlation coefficients of 0.9987 and 0.9968 for ACE and MET, respectively. Repeatability studies demonstrated the %RSD of 0.63 and 0.74% for MET and ACE. At the same time, reproducibility studies displayed the %RSD of 1.057 and 1.178% for MET and ACE, respectively. Spike recovery experiments were carried out to assess the performance of MSPE in real samples, and over 88% of both analytes were recovered. This indicated that the MSPE method could enrich various organic pollutants from different environmental matrices.
引用
收藏
页码:3343 / 3359
页数:17
相关论文
共 50 条
  • [1] Development of a coupled dispersive liquid-liquid micro-extraction with supported liquid phase micro-extraction for triclosan determination in wastewater
    Letseka, Thabiso
    George, Mosotho J.
    WATER SA, 2018, 44 (01) : 13 - 19
  • [2] Simultaneous extraction and preconcentration of three beta (ß)-blockers in biological samples with an efficient magnetic dispersive micro-solid phase extraction procedure employing in situ sorbent modification
    Abadi, Mohammad Ameri Akhtiar
    Mahboubeh, Masrournia A.
    Abedi, Mohamad Reza
    MICROCHEMICAL JOURNAL, 2021, 163
  • [3] Determination of PAHs in diesel particulate matter using thermal extraction and solid phase micro-extraction
    Ballesteros, R.
    Hernandez, J. J.
    Lyons, L. L.
    ATMOSPHERIC ENVIRONMENT, 2009, 43 (03) : 655 - 662
  • [4] ZnO nanorod array solid phase micro-extraction fiber coating: fabrication and extraction capability
    Wang, Dan
    Zhang, Zhuomin
    Luo, Lin
    Li, Tiemei
    Zhang, Lan
    Chen, Guonan
    NANOTECHNOLOGY, 2009, 20 (46)
  • [5] Solid-phase micro-extraction of drugs from biological matrices
    Snow, NH
    JOURNAL OF CHROMATOGRAPHY A, 2000, 885 (1-2) : 445 - 455
  • [6] Fabrication of the Monolithic Fiber for the Solid Phase Micro-extraction of Malachite Green
    Hu, Mei
    Chen, Jin
    Yang, Jing-Hua
    Zhang, Yu-Ping
    Zhou, Xiao-Mao
    Bai, Lian-Yang
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2015, 62 (04) : 305 - 310
  • [7] Evaluation of needle trap micro-extraction and solid-phase micro-extraction: Obtaining comprehensive information on volatile emissions from in vitro cultures
    Oertel, Peter
    Bergmann, Andreas
    Fischer, Sina
    Trefz, Phillip
    Kuentzel, Anne
    Reinhold, Petra
    Koehler, Heike
    Schubert, Jochen K.
    Miekisch, Wolfram
    BIOMEDICAL CHROMATOGRAPHY, 2018, 32 (10)
  • [8] Self-effervescence-assisted dispersive micro-solid-phase extraction combined with dispersive liquid-liquid micro-extraction for the extraction and preconcentration of some phthalate and adipate esters in sparkling water
    Pezhhanfar, Sakha
    Farajzadeh, Mir Ali
    Mirzaahmadi, Azadeh
    Hosseini-Yazdi, Seyed Abolfazl
    Mogaddam, Mohammad Reza Afshar
    CHEMICAL PAPERS, 2023, 77 (07) : 4041 - 4055
  • [9] Optimization of the extraction conditions of the volatile compounds from chili peppers by headspace solid phase micro-extraction
    Bogusz Junior, Stanislau
    Tavares de Melo, Arlete de Marchi
    Zini, Claudia Alcaraz
    Godoy, Helena Teixeira
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (21) : 3345 - 3350
  • [10] Improved Detection Limits for Phthalates by Selective Solid-phase Micro-extraction
    Zia, Asif I.
    Afsarimanesh, Nasrin
    Xie, Li
    Nag, Anindya
    Al-Bahadly, I. H.
    Yu, P. L.
    Kosel, Jurgen
    2015 9TH INTERNATIONAL CONFERENCE ON SENSING TECHNOLOGY (ICST), 2015, : 733 - 738