Inter-rater and Intra-rater Reliability of a Mobile App Method to Measure Lumbar Lordosis

被引:0
|
作者
Gnanasigamani, Jency Thangasheela [1 ]
Ramalingam, Vinodhkumar [1 ]
机构
[1] Saveetha Univ, Saveetha Inst Med & Tech Sci, Saveetha Coll Physiotherapy, Physiotherapy, Chennai, India
关键词
low back pain; lateral view radiograph; assessment; reliability; angle; mobile app; lordosis; CONCURRENT VALIDITY; PELVIC TILT; MUSCLE; CURVATURE; SPINE;
D O I
10.7759/cureus.55489
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Measuring the exact quantitative values of lordotic curves is a vital factor in clinical settings to prevent musculoskeletal deformities in the future. Existing lordotic assessment methods are very diverse, expensive, inaccurate, and not handy, and their availability cannot be maintained in every clinic setup. Aim The purpose of this research was to study the reliability of a mobile app as a feasible method to measure lumbar lordosis angle using a lateral view radiograph. Methodology A lateral view low back region radiograph of 58 participants was taken based on the criteria, and the experienced physiotherapists uploaded the X-ray to the mobile app and measured the lordotic angles with the support of machine learning algorithms. Descriptive statistics were used to calculate the average and dispersion of the data of the lumbar lordosis angle measured using the mobile app method (Statistical Package for the Social Sciences (IBM SPSS Statistics for Windows, IBM Corp., Version 23, Armonk, NY)). Results Associations between and within raters were assessed using the Karl Pearson coefficient of correlation (1.000). Inter -rater and intra-rater reliability were determined by using Cronbach's alpha (.966) and the split -half method. The internal consistency of the mobile app was found to be good. Conclusions Based on our findings, we conclude that the mobile app method is reliable and useful in measuring lumbar lordosis objectively with less effort. Since the app is handy on smartphones, physiotherapists can conduct an objective lumbar lordosis assessment in clinical settings.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Measuring Essay Assessment: Intra-rater and Inter-rater Reliability
    Kayapinar, Ulas
    EURASIAN JOURNAL OF EDUCATIONAL RESEARCH, 2014, (57): : 113 - 135
  • [2] Intra-rater and inter-rater reliability of robotic arthrometer DYNEELAX®
    Mihalinec, Katja
    Martinez-Cepa, Carmen B.
    Zuil-Escobar, Juan C.
    Kejzar, Natasa
    Vauhnik, Renata
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2024, 11 (03)
  • [3] Intra-rater and inter-rater reliability of the Empathic Communication Coding System
    Ju, Yu-Jeng
    Lee, Meng-Lin
    Chen, Jou-Chieh
    Wang, Yi-Ching
    Chen, Chih-Ping
    Tsai, Han-En
    Wu, Tzu-Yi
    Hsieh, Ching-Lin
    BRITISH JOURNAL OF OCCUPATIONAL THERAPY, 2025,
  • [4] Inter-Rater and Intra-Rater Reliability of the Kansas University Sitting Balance Scale
    Franc, Ingrid A.
    Mauldin, Samantha
    Roberts, Magdalena
    Rosa-DiStefano, Gregoria
    OCCUPATIONAL THERAPY IN HEALTH CARE, 2023, 37 (04) : 595 - 605
  • [5] Inter-rater and intra-rater reliability of the airway diameter measured by sonography
    Gómez-Tamayo J.C.
    Puerta-Guarín J.I.
    Rojas-Camejo C.M.
    Caicedo J.P.
    Calvache J.A.
    Journal of Ultrasound, 2018, 21 (1) : 35 - 40
  • [6] Optoelectronic plethysmography: Intra-rater and inter-rater reliability in healthy subjects
    Vieira, Danielle S. R.
    Hoffman, Mariana
    Pereira, Danielle A. G.
    Britto, Raquel R.
    Parreira, Veronica F.
    RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2013, 189 (03) : 473 - 476
  • [7] Ultrasound Imaging Analysis of the Lumbar Multifidus Muscle Echo Intensity: Intra-Rater and Inter-Rater Reliability of a Novice and an Experienced Rater
    Fortin, Maryse
    Rosenstein, Brent
    Levesque, Jerome
    Nandlall, Neil
    MEDICINA-LITHUANIA, 2021, 57 (05):
  • [8] Inter-rater, intra-rater and inter-instrument reliability of an electrogoniometer to measure wrist range of motion
    da Silva Camassuti, Patricia Aparecida
    Marcolino, Alexandre Marcio
    Tamanini, Guilherme
    Barbosa, Rafael Inacio
    Barbosa, Amanda Matias
    Registro Fonseca, Marisa de Cassia
    HAND THERAPY, 2015, 20 (01) : 3 - 10
  • [9] Inter-rater and Intra-rater Reliability of the Videofluoroscopic Dysphagia Scale with the Standardized Protocol
    Min, Ingi
    Woo, Hyeonseong
    Kim, Jae Yoon
    Kim, Tae-Lim
    Lee, Yookyung
    Chang, Won Kee
    Jung, Se Hee
    Lee, Woo Hyung
    Oh, Byung-Mo
    Han, Tai Ryoon
    Seo, Han Gil
    DYSPHAGIA, 2024, 39 (01) : 43 - 51
  • [10] Inter-rater and Intra-rater Reliability of the Videofluoroscopic Dysphagia Scale with the Standardized Protocol
    Ingi Min
    Hyeonseong Woo
    Jae Yoon Kim
    Tae-Lim Kim
    Yookyung Lee
    Won Kee Chang
    Se Hee Jung
    Woo Hyung Lee
    Byung-Mo Oh
    Tai Ryoon Han
    Han Gil Seo
    Dysphagia, 2024, 39 : 43 - 51