Highly Sensitive Determination of Cadmium by Atomic Emission Spectrometry with Miniaturized Solution Anode Glow Discharge

被引:1
作者
Yu, Jie [1 ]
Wang, Xuyi [1 ]
Cui, Lijuan [1 ]
Hao, Xiaoxia [1 ]
Lu, Quanfang [1 ,2 ]
机构
[1] Northwest Normal Univ, Coll Chem & Chem Engn, Lanzhou 730070, Peoples R China
[2] Northwest Normal Univ, Editorial Dept Univ Journal, Lanzhou 730070, Peoples R China
基金
中国国家自然科学基金;
关键词
solution anode glow discharge; atomic emission spectrometry; highly sensitive determination; cadmium; carrot; FLOWING LIQUID CATHODE; DROP-SPARK DISCHARGE; ATMOSPHERIC-PRESSURE; ANALYTICAL PERFORMANCE; SAMPLE INTRODUCTION; FORMIC-ACID; CD; IMPROVEMENT; GENERATION; CONTACT;
D O I
10.1134/S106193482470059X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A solution anode glow discharge (SAGD) was established as a miniaturized excitation source of atomic emission spectrometry (AES) for the detection of Cd in rhizosphere soil, carrot, and carrot leaf samples. The working conditions, such as electrolyte pH, discharge voltage, support electrolyte, solution flow rate, and discharge distance, were systematically optimized. The effect of 31 foreign ions on the Cd determination was investigated. In addition, the influences of matrix modifiers on the Cd signal intensity and interference elimination were examined in detail. The results showed that under the optimal operating parameters, the presence of Fe3+, Co2+, Pb2+, Cu2+, Cr3+, and Tl3+ ions at 30 mg/L causes severe depression effects for the detection of Cd, and adding ascorbic acid as a matrix modifier can reduce the matrix interference, improve sensitivity, and lower the limit of detection (LOD). The LOD of Cd is 4.4 mu g/L, and power is below 8 W using SAGD without any matrix modifier. Compared with the solution cathode glow discharge-atomic emission spectrometry (SCGD-AES), the sensitivity is improved about 11-fold, and the power is consumed only about one-sixth. The analysis results of SAGD-AES are in agreement with the Cd-certified reference material and verification values measured by inductively coupled plasma atomic emission spectroscopy, suggesting that proposed method has high accuracy and reliability.
引用
收藏
页码:1229 / 1241
页数:13
相关论文
共 42 条
[1]   Evaluation of solution anode glow discharge as a vapor generator in ICP-OES procedures: Application to highly sensitive determination of Cd and Hg [J].
Cai, Zhaoqing ;
Wang, Zheng .
ANALYTICA CHIMICA ACTA, 2022, 1203
[2]   2017 WHO Guidelines for Drinking Water Quality: First Addendum to the Fourth Edition [J].
Cotruvo, Joseph A. .
JOURNAL AMERICAN WATER WORKS ASSOCIATION, 2017, 109 (07) :44-51
[3]   DIRECT SOLUTION ANALYSIS BY GLOW-DISCHARGE - ELECTROLYTE-CATHODE DISCHARGE SPECTROMETRY [J].
CSERFALVI, T ;
MEZEI, P .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (03) :345-349
[4]   EMISSION STUDIES ON A GLOW-DISCHARGE IN ATMOSPHERIC-PRESSURE AIR USING WATER AS A CATHODE [J].
CSERFALVI, T ;
MEZEI, P ;
APAI, P .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1993, 26 (12) :2184-2188
[5]   Determination and validation of soil thresholds for cadmium based on food quality standard and health risk assessment [J].
Ding, Changfeng ;
Ma, Yibing ;
Li, Xiaogang ;
Zhang, Taolin ;
Wang, Xingxiang .
SCIENCE OF THE TOTAL ENVIRONMENT, 2018, 619 :700-706
[6]   Solution-cathode glow discharge - optical emission spectrometry of a new design and using a compact spectrograph [J].
Doroski, Todd A. ;
King, Allison M. ;
Fritz, Michael P. ;
Webb, Michael R. .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2013, 28 (07) :1090-1095
[7]   Cadmium exposure triggers mitochondrial dysfunction and oxidative stress in chicken (Gallus gallus) kidney via mitochondrial UPR inhibition and Nrf2-mediated antioxidant defense activation [J].
Ge, Jing ;
Zhang, Cong ;
Sun, Yan-Chun ;
Zhang, Qi ;
Lv, Mei-Wei ;
Guo, Kai ;
Li, Jin-Long .
SCIENCE OF THE TOTAL ENVIRONMENT, 2019, 689 :1160-1171
[8]   Comparison of the performance of atmospheric pressure glow discharges operated between a flowing liquid cathode and either a pin-type anode or a helium jet anode for the Ga and In determination by the optical emission spectrometry [J].
Gorska, Monika ;
Pohl, Pawel .
TALANTA, 2021, 226
[9]   Determination of bismuth by optical emission spectrometry with liquid anode/cathode atmospheric pressure glow discharge [J].
Gorska, Monika ;
Greda, Krzysztof ;
Pohl, Pawel .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2021, 36 (01) :165-177
[10]   Study and reduction of matrix effects in flowing liquid anode Atmospheric pressure glow discharge - Optical emission spectrometry [J].
Greda, Krzysztof ;
Szymczycha-Madeja, Anna ;
Pohl, Pawel .
ANALYTICA CHIMICA ACTA, 2020, 1123 :81-90