Restoration of magnetohydrodynamic-corrupted 12-lead electrocardiogram to enhance cardiac monitoring during magnetic resonance imaging

被引:0
|
作者
Mahmud, Sakib [1 ]
Chowdhury, Muhammad E. H. [1 ]
Chowdhury, Moajjem Hossain [2 ]
Alqahtani, Abdulrahman [3 ,4 ]
Bin Mahbub, Zaid [5 ]
Bensaali, Faycal [1 ]
Kiranyaz, Serkan [1 ]
机构
[1] Qatar Univ, Dept Elect Engn, Doha, Qatar
[2] Univ Kebangsaan Malaysia, Dept Elect Elect & Syst Engn, Bangi 43600, Malaysia
[3] Prince Sattam Bin Abdulaziz Univ, Coll Appl Med Sci Al Kharj, Dept Biomed Technol, Al Kharj 11942, Saudi Arabia
[4] Majmaah Univ, Coll Appl Med Sci, Dept Med Equipment Technol, Majmaah City 11952, Saudi Arabia
[5] North South Univ, Dept Phys & Math, Dhaka, Bangladesh
关键词
Magnetohydrodynamics corrupted; electrocardiogram restoration; Magnetic resonance imaging; Cardiac monitoring; Unpaired signal restoration; One dimensional-Segmentation; QRS COMPLEX; HEART-RATE; ECG; MRI; ALGORITHM; SUPPRESSION; EXTRACTION; POLARITY; SAFETY;
D O I
10.1016/j.engappai.2024.108483
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The Magnetohydrodynamic (MHD) effect on the bloodstream, induced by the static magnetic field of Magnetic Resonance Imaging (MRI) devices, distorts Electrocardiogram (ECG) components, and poses challenges to cardiac gating and monitoring during MRI examinations. Restoring ECG components from MHD-induced artifacts has always been a challenge, primarily due to the influence of numerous device-induced and physiological variables and the absence of paired ground truth clean ECG for validation. In this research, at first, we employ unpaired restoration of MHD-corrupted 12-lead ECG signals using one dimensional (1D) Cycle Generative Adversarial Networks (CycleGANs) for channel and patient orientation-specific restoration. Subsequently, a 1Dsegmentation-based comprehensive restoration scheme is proposed based on the phase 1 outputs to simultaneously restore 12-channel ECG signals, irrespective of internal and external factors affecting ECG. By employing the proposed Magnetohydrodynamic Generative Adversarial Network ( MHDGAN) and MHD-to-ECG Network (MHD2ECGNet) for unpaired and comprehensive restoration, we achieved an overall spectral correlation improvement of 92.56% and 77.64% , respectively. In R-peak detection, MHDGAN demonstrated an overall precision, recall, and F1-score of 98.14% , 94.12% , and 96.01% , respectively. The extracted heart rate (HR) and heart rate variability (HRV) from the restored waveforms closely match the ground truth, as confirmed through quantitative and qualitative assessments. The proposed framework has proven effective in restoring MHDcorrupted ECG waveforms, even in the absence of paired ground truth labels and amidst compounding distortions from multiple sources.
引用
收藏
页数:27
相关论文
共 6 条
  • [1] Left ventricular mass by 12-lead electrocardiogram in healthy subjects:: comparison to cardiac magnetic resonance imaging
    Carlsson, MB
    Trägårdh, E
    Engblom, H
    Hedström, E
    Wagner, G
    Pahlm, O
    Arheden, H
    JOURNAL OF ELECTROCARDIOLOGY, 2006, 39 (01) : 67 - 72
  • [2] EASI-Derived vs standard 12-lead electrocardiogram for Selvester QRS score estimations of chronic myocardial infarct size, using cardiac magnetic resonance imaging as gold standard
    Welinder, Annika E.
    Wagner, Galen S.
    Horacek, B. Milan
    Martin, Thomas N.
    Maynard, Charles
    Pahlm, Olle
    JOURNAL OF ELECTROCARDIOLOGY, 2009, 42 (02) : 145 - 151
  • [3] Screening for Cardiac Magnetic Resonance Scar Features by 12-Lead ECG, in Patients with Preserved Ejection Fraction
    Mewton, Nathan
    Strauss, David G.
    Rizzi, Patricia
    Verrier, Richard L.
    Liu, Chia Ying
    Tereshchenko, Larisa G.
    Nearing, Bruce
    Volpe, Gustavo J.
    Marchlinski, Francis E.
    Moxley, John
    Killian, Tony
    Wu, Katherine C.
    Spooner, Peter
    Lima, Joao A. C.
    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2016, 21 (01) : 49 - 59
  • [4] A Generative Adversarial Network to Synthesize 3D Magnetohydrodynamic Distortions for Electrocardiogram Analyses Applied to Cardiac Magnetic Resonance Imaging
    Mehri, Maroua
    Calmon, Guillaume
    Odille, Freddy
    Oster, Julien
    Lalande, Alain
    SENSORS, 2023, 23 (21)
  • [5] Association of Left Ventricular Diffuse Fibrosis and Scar Assessed by Cardiac Magnetic Resonance Imaging With Depolarization and Repolarization on 12-Lead Electrocardiography: MESA (Multi-Ethnic Study of Atherosclerosis)
    Inoue, Yuko Y.
    Ashikaga, Hiroshi
    Ambale-Venkatesh, Bharath
    Volpe, Gustavo J.
    Mewton, Nathan
    Ohyama, Yoshiaki
    Sharma, Ravi K.
    Wu, Colin O.
    Liu, Chia-Ying
    Bluemke, David A.
    Soliman, Elsayed Z.
    Lima, Joao A.
    CIRCULATION, 2015, 132
  • [6] Extended Ablation Lesions Do Not Lead Permanent Impairment of Left Atrial Function Left Atrial Function Assessment by Cardiac Magnetic Resonance Imaging After Atrial Fibrillation Ablation in Acute Phase and During Follow-Up
    Csecs, Ibolya
    Yamaguchi, Takanori
    Kheirkhahan, Mobin
    Peritz, David
    Kaur, Gagandeep
    Kholmovski, Evgueni
    Morris, Alan
    Wilson, Brent D.
    Merkely, Bela
    Marrouche, Nassir
    CIRCULATION, 2018, 138