A robust and simple catheter connector assembly for long-term self-administration experiments

被引:2
作者
Suarez, Mauricio [1 ]
Charntikov, Sergios [2 ]
Huynh, Y. Wendy [3 ]
Barrett, Scott T. [3 ]
Bevins, Rick A. [3 ]
Wakabayashi, Ken T. [1 ]
机构
[1] Univ Nebraska Lincoln, Dept Psychol, Neurocircuitry Motivated Behav Lab, 1220 T St, Lincoln, NE 68588 USA
[2] Univ New Hampshire, Dept Psychol, 468 McConnell Hall,15 Acad Way, Durham, NH 03824 USA
[3] Univ Nebraska Lincoln, Dept Psychol, Behav Neuropharmacol Lab, 1220 T St Lincol, Lincoln, NE 68588 USA
关键词
Self-Administration; Jugular Catheter; Long-Lasting; Surgery; In-House Construction; Intravenous Drug Delivery; Drug Use and Abuse; Rat;
D O I
10.1016/j.mex.2024.102675
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Intravenous self -administration in rats is used widely to study the reinforcing effects of drugs and serves as the gold standard for assessing their use and misuse potential. One challenge that researchers often encounter when scaling up experiments is balancing the cost, time investment to construct, and robustness of each implanted catheter. These catheters include multiple components such as surgical meshing and a variety of entry ports designed to facilitate the connection of the rat to a catheter port tethering system. Other considerations include maintaining the catheters free of blockage during the extent of the drug self -administration experiment. These large-scale studies provide ample opportunity for the catheter system to fail. The failure and replacement of commercially purchased catheters leads to ballooning expenses, and the failure of in -lab manufactured catheters requires the manufacture of reserves, also increasing costs, as these handmade products are inherently more variable. We have developed a catheter system that combines a commercially available implantable back -mounted entry connector system with inexpensive medical items such as surgical mesh, sutures, and an air -tight back flow prevention system to bolster the overall success of self -administration experiments. center dot Method to bolster commercially available jugular catheter components for long-lasting selfadministration experiments. center dot Reduces the overall cost per unit of self -administration experiments. center dot Easily assembled by laboratory students and staff.
引用
收藏
页数:7
相关论文
共 5 条
  • [1] Appetitive Pavlovian conditioning of the stimulus effects of nicotine enhances later nicotine self-administration
    Barrett, Scott T.
    Flynn, Allissa T.
    Huynh, Y. Wendy
    Bevins, Rick A.
    [J]. JOURNAL OF THE EXPERIMENTAL ANALYSIS OF BEHAVIOR, 2022, 117 (03) : 543 - 559
  • [2] Catheterization of the Carotid Artery and Jugular Vein to Perform Hemodynamic Measures, Infusions and Blood Sampling in a Conscious Rat Model
    Feng, Jing
    Fitz, Yvonne
    Li, Yan
    Fernandez, Melinda
    Puch, Irene Cortes
    Wang, Dong
    Pazniokas, Stephanie
    Bucher, Brandon
    Cui, Xizhong
    Solomon, Steven B.
    [J]. JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2015, (95):
  • [3] Assembly of an inexpensive rat jugular catheter button based on a split-septum needleless intravenous system
    Suarez, Mauricio
    Cantrell, Elizabeth J.
    Wakabayashi, Ken T.
    Bass, Caroline E.
    [J]. METHODSX, 2023, 11
  • [5] In vivo quantitative assessment of catheter patency in rats
    Yang, J
    Maarek, JMI
    Holschneider, DP
    [J]. LABORATORY ANIMALS, 2005, 39 (03) : 259 - 268