Diagnostic value of combined ultrasound contrast and elastography for differentiating benign and malignant thyroid nodules: a meta-analysis

被引:3
作者
Liu, Funing [1 ]
Wang, Yihan [2 ]
Xiong, Yu [1 ]
Li, Xin [3 ]
Yao, Jun [4 ]
Ju, Hao [5 ]
Ren, Fu [6 ,7 ,8 ]
Zhang, Luwei [9 ]
Wang, Hongbo [6 ,7 ,8 ]
机构
[1] Shenyang Med Coll, Sch Clin Coll 1, Shenyang, Peoples R China
[2] Shenyang Med Coll, Sch Publ Hlth, Shenyang, Peoples R China
[3] Shenyang Med Coll, Sch Stomatol, Shenyang, Peoples R China
[4] China Med Univ, Sch Forens Med, Shenyang, Peoples R China
[5] China Med Univ, Shengjing Hosp, Shenyang, Peoples R China
[6] Shenyang Med Coll, Sch Basic Med, Dept Human Anat, Shenyang, Peoples R China
[7] Key Lab Human Ethn Specif & Phen Crit Illness Liao, Shenyang, Peoples R China
[8] Key Lab Phen Res, 146 Huanghe North St, Shenyang 110034, Liaoning, Peoples R China
[9] Shenyang Med Coll, Hosp 242, Shenyang, Peoples R China
关键词
Contrast-enhanced ultrasound; Ultrasonic elastography; Thyroid nodules; Meta-analysis; ENHANCED ULTRASOUND; ULTRASONOGRAPHY; MANAGEMENT; CANCER;
D O I
10.1038/s41598-024-63420-1
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The diagnostic value of contrast-enhanced ultrasound combined with ultrasound elastography for benign and malignant thyroid nodules is still controversial, so we used meta-analysis to seek controversial answers. The PubMed, OVID, and CNKI databases were searched according to the inclusion and exclusion criteria. The literature was selected from the establishment of each database to February 2024. The QUADAS-2 tool assessed diagnostic test accuracy. SROC curves and Spearman's correlation coefficient were made by Review Manager 5.4 software to assess the presence of threshold effects in the literature. Meta-Disc1.4 software was used for Cochrane-Q and chi 2 tests, which be used to evaluate heterogeneity, with P-values and I 2 indicating heterogeneity levels. The appropriate effect model was selected based on the results of the heterogeneity test. Stata18.0 software was used to evaluate publication bias. The diagnostic accuracy of contrast-enhanced ultrasound combined with ultrasound elastography for benign and malignant thyroid nodules was evaluated by calculating the combined sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, DOR, and area under the SROC curve. A total of 31 studies included 3811 patients with 4718 nodules were analyzed. There is no heterogeneity caused by the threshold effect, but there is significant non-threshold heterogeneity. Combined diagnostic metrics were: sensitivity = 0.93, specificity = 0.91, DOR = 168.41, positive likelihood ratio = 10.60, and negative likelihood ratio = 0.07. The SROC curve area was 0.97. Contrast-enhanced ultrasound and elastography show high diagnostic accuracy for thyroid nodules, offering a solid foundation for early diagnosis and treatment.Trial registration. CRD42024509462.
引用
收藏
页数:11
相关论文
共 55 条
[1]   The association of colour flow Doppler sonography and conventional ultrasonography improves the diagnosis of thyroid carcinoma [J].
Appetecchia, M. ;
Solivetti, F. M. .
HORMONE RESEARCH, 2006, 66 (05) :249-256
[2]  
Bangfa W., 2017, Chin. J. Convalescent. Med, V26, P935, DOI [10.13517/j.cnki.ccm.2017.09.017, DOI 10.13517/J.CNKI.CCM.2017.09.017]
[3]   Qualitative and quantitative evaluation of solitary thyroid nodules with contrast-enhanced ultrasound: initial results [J].
Bartolotta, Tommaso Vincenzo ;
Midiri, Massimo ;
Galia, Massimo ;
Runza, Giuseppe ;
Attard, Marco ;
Savoia, Giovanni ;
Lagalla, Roberto ;
Cardinale, Adelfio Elio .
EUROPEAN RADIOLOGY, 2006, 16 (10) :2234-2241
[4]   EVALUATION AND MANAGEMENT OF THE SOLID THYROID-NODULE [J].
BURCH, HB .
ENDOCRINOLOGY AND METABOLISM CLINICS OF NORTH AMERICA, 1995, 24 (04) :663-+
[5]   Motion correction of 3D dynamic contrast-enhanced ultrasound imaging without anatomical B-Mode images: Pilot evaluation in eight patients [J].
Chen, Jia-Shu ;
Goubran, Maged ;
Kim, Gaeun ;
Kim, Matthew J. ;
Willmann, Jurgen K. ;
Zeineh, Michael ;
Hristov, Dimitre ;
El Kaffas, Ahmed .
MEDICAL PHYSICS, 2024, 51 (07) :4827-4837
[6]   Shear wave elastography and contrast-enhanced ultrasonography in the diagnosis of thyroid malignant nodules [J].
Chen, Mei ;
Zhang, Ke-Qin ;
Xu, You-Feng ;
Zhang, Sheng-Min ;
Cao, Yong ;
Sun, Wei-Qun .
MOLECULAR AND CLINICAL ONCOLOGY, 2016, 5 (06) :724-730
[7]  
Chowdhury Subhankar, 2006, J Indian Med Assoc, V104, P568
[8]  
Chun M., 2017, J. Aerosp. Med, V28, P693
[9]  
Dan L., 2015, Progr. Mod. Biomed, V15, P2123, DOI [10.13241/j.cnki.pmb.2015.11.034, DOI 10.13241/J.CNKI.PMB.2015.11.034]
[10]  
Deng J., 2013, The differential diagnosis of the thyroid nodules:value ofthe contrast-enhanced ultrasound compared with acousticradiation force impulse imaging