Recent progress of continuous intraocular pressure monitoring

被引:11
作者
Xu, Jiandong [1 ,2 ]
Li, Ruisong [5 ,6 ]
Xu, Haokai [1 ,2 ]
Yang, Yi [1 ,2 ]
Zhang, Sheng [3 ]
Ren, Tian-Ling [1 ,2 ,4 ]
机构
[1] Tsinghua Univ, Inst Microelect, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Beijing Natl Res Ctr Informat Sci & Technol BNRis, Beijing 100084, Peoples R China
[3] Tsinghua Univ, Shenzhen Int Grad Sch, Shenzhen 518055, Peoples R China
[4] Tsinghua Univ, Ctr Flexible Elect Technol, Beijing 100084, Peoples R China
[5] Univ Calif Berkeley, Dept Elect Engn & Comp Sci, Coll Engn, Berkeley, CA 94720 USA
[6] Univ Calif Berkeley, Dept Bioengn, Coll Engn, Berkeley, CA 94720 USA
来源
NANO SELECT | 2022年 / 3卷 / 01期
基金
中国国家自然科学基金;
关键词
contact lens; continuous monitoring; glaucoma; implantable sensor; IOP; CONTACT-LENS SENSOR; GLAUCOMA PROGRESSION; GLOBAL PREVALENCE; DRUG-DELIVERY; TRANSDUCER; IMPLANTATION; SYSTEM; SAFETY; FIELD;
D O I
10.1002/nano.202100137
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Glaucoma, a chronic optic neuropathy, is the leading cause of irreversible blindness in the world. Elevated intraocular pressure (IOP) has been considered to be the major contributor to glaucoma for a long time and is currently proved to be the only modifiable risk factor for the progression of optic neuropathy. IOP fluctuates throughout the day with a circadian rhythm change and is affected by body gesture changes. Moreover, the IOP spike usually occurs at night or in the early morning. Therefore, the current clinical practice of single and static measurements of IOP during office hours is not conducive to the early diagnosis and treatment of glaucoma. This review focuses on current advances in implantable and noninvasive IOP sensors for obtaining 24-hour continuous IOP profiles. The content summarizes and classifies IOP sensors based on their working principles and provides representative examples of the sensors for IOP monitoring. Finally, the review further analyzes the challenges of current IOP sensors for clinical practice and puts forward the prospect of IOP sensors in the future.
引用
收藏
页码:1 / 19
页数:19
相关论文
共 123 条
[1]   Ultra-sensitive microfluidic wearable strain sensor for intraocular pressure monitoring [J].
Agaoglu, Sevda ;
Diep, Priscilla ;
Martini, Matthew ;
Samudhyatha, K. T. ;
Baday, Murat ;
Araci, I. Emre .
LAB ON A CHIP, 2018, 18 (22) :3471-3483
[2]  
Agarwal A, 2018, IEEE CUST INTEGR CIR
[3]   High-sensitivity liquid-metal-based contact lens sensor for continuous intraocular pressure monitoring [J].
An, Hongbin ;
Chen, Liangzhou ;
Liu, Xiaojun ;
Wang, Xiangyang ;
Liu, Yunfeng ;
Wu, Zhigang ;
Zhao, Bin ;
Zhang, Hong .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2021, 31 (03)
[4]   Microfluidic contact lenses for unpowered, continuous and non-invasive intraocular pressure monitoring [J].
An, Hongbin ;
Chen, Liangzhou ;
Liu, Xiaojun ;
Zhao, Bin ;
Zhang, Hong ;
Wu, Zhigang .
SENSORS AND ACTUATORS A-PHYSICAL, 2019, 295 :177-187
[5]   Flow stabilization in wearable microfluidic sensors enables noise suppression [J].
Araci, I. Emre ;
Agaoglu, Sevda ;
Lee, Ju Young ;
Rivas Yepes, Laura ;
Diep, Priscilla ;
Martini, Matthew ;
Schmidt, Andrew .
LAB ON A CHIP, 2019, 19 (22) :3899-3908
[6]   An implantable microfluidic device for self-monitoring of intraocular pressure [J].
Araci, Ismail E. ;
Su, Baolong ;
Quake, Stephen R. ;
Mandel, Yossi .
NATURE MEDICINE, 2014, 20 (09) :1074-1078
[7]  
Arora Tarun, 2015, J Optom, V8, P239, DOI 10.1016/j.optom.2014.05.005
[8]  
Arsalan M, 2013, IEEE MTT S INT MICR
[9]   A passive pressure sensor for continuously measuring the intraocular pressure in glaucomatous patients [J].
Auvray, P. ;
Rousseau, L. ;
Lissorgues, G. ;
Soulier, F. ;
Potin, O. ;
Bernard, S. ;
Dieuleveult, F. ;
Scorsone, E. ;
Bergonzo, P. ;
Chicaud, L. ;
Picaud, S. ;
Sahel, J. A. .
IRBM, 2012, 33 (02) :117-122
[10]   Clinical utility of Intraocular pressure monitoring outside of normal office hours in patients with glaucoma [J].
Barkana, Yaniv ;
Anis, Sarah ;
Liebmann, Jeffrey ;
Tello, Celso ;
Ritch, Robert .
ARCHIVES OF OPHTHALMOLOGY, 2006, 124 (06) :793-797