Quality index for Martian in-situ laser-induced breakdown spectroscopy data

被引:1
|
作者
Chen, Zhaopeng [1 ,2 ,3 ]
Forni, Olivier [2 ]
Cousin, Agnes [2 ]
Pilleri, Paolo [2 ]
Gasnault, Olivier [2 ]
Maurice, Sylvestre [2 ]
Wiens, Roger C. [4 ]
Zhang, Yizhong [1 ,3 ]
Luo, Yuxuan [1 ,3 ]
Ren, Xin [1 ]
Xu, Weiming [5 ]
Liu, Xiangfeng [5 ]
Shu, Rong [5 ]
Li, Chunlai [1 ]
机构
[1] Chinese Acad Sci, Key Lab Lunar & Deep Space Explorat, Natl Astron Observ, 20A Datun Rd, Beijing 100101, Peoples R China
[2] Univ Toulouse, Inst Rech Astrophys & Planetol, UPS, CNRS, 9 Ave Colonel Roche, F-31400 Toulouse, France
[3] Univ Chinese Acad Sci, Sch Astron & Space Sci, 19A Yuquan Rd, Beijing 100049, Peoples R China
[4] Purdue Univ, Earth Atmospher & Planetary Sci, 610 Purdue Mall, W Lafayette, IN 47906 USA
[5] Chinese Acad Sci, Shanghai Inst Tech Phys, 500 Yutian Rd, Shanghai 200083, Peoples R China
关键词
Laser-induced breakdown spectroscopy; Data quality; Mars exploration; Mars atmosphere; CHEMCAM INSTRUMENT SUITE; CURIOSITY ROVER; MARS; IDENTIFICATION; EMISSION; TARGETS; MATRIX; LIBS; UNIT;
D O I
10.1016/j.sab.2024.106921
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Laser -induced breakdown spectroscopy (LIBS) has been widely implemented in Mars explorations as a versatile technique for in -situ chemical analysis. Determination of elemental composition from Martian LIBS typically relies on uni/multi-variate models trained on specific laboratory datasets, which in turn requires similarities between this training dataset and Martian data. However, plasma excitation can affect this similarity. The inability to identify insufficiently excited data may ignore poor focusing for some observations or lead to unawareness of compositional uncertainty. This study establishes the LIBS Quality Index (LQI) for Martian LIBS data quality by evaluating the carbon ionic doublet emission around 658 nm for the Martian atmosphere, assessing its signal-to-noise ratio as well as its deviation from the line profile standard of the instrument -specific laboratory dataset. This method allows the LQI to be used as a confidence level for assessing LIBS excitation quality and measurement for similarity with instrument -specific laboratory datasets. The LQI evaluation routines were established for ChemCam, MarSCoDe, and SuperCam. Validation of LQI was carried out on the laboratory datasets and Mars data with known quality assessments of the three instruments. The index was verified to be sensitive to input irradiance, applicable with three current Mars LIBS instruments, robust against various material types (except carbonate), and moderate interference from H, Fe, and Ti. Applying the LQI, the study was able to identify the remote micro -imager (RMI) autofocus as an optimal mechanism, to discover the influence of environmental conditions on data quality, to discuss the impact of target material consolidation and morphology on data quality, and to investigate the contribution of data quality to quantification uncertainty. These application examples demonstrated the feasibility of LQI as a useful and sensitive tool to assess data quality and its potential to aid current and future Martian LIBS explorations.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Miniaturized Laser-Induced Breakdown Spectroscopy for the in-situ analysis of the Martian surface: Calibration and quantification
    Rauschenbach, I.
    Jessberger, E. K.
    Pavlov, S. G.
    Huebers, H.-W.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2010, 65 (08) : 758 - 768
  • [2] In-situ Analysis of Molten Aluminum by Laser-induced Breakdown Spectroscopy System
    Xin Yong
    Li Yang
    Li Wei
    Liu Xue
    Li Jing-jing
    Yang Zhi-jia
    Yu Hai-bin
    Sun Lan-xiang
    ACTA PHOTONICA SINICA, 2018, 47 (08)
  • [3] In-situ diagnostics of combustion parameters using laser-induced breakdown spectroscopy
    Lee, T. -W.
    Hegde, N.
    Han, I.
    HT2005: Proceedings of the ASME Summer Heat Transfer Conference 2005, Vol 1, 2005, : 713 - 718
  • [4] Rapid in-situ analysis of liquid steel by laser-induced breakdown spectroscopy
    Gruber, J
    Heitz, J
    Strasser, H
    Bäuerle, D
    Ramaseder, N
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2001, 56 (06) : 685 - 693
  • [5] Quantitative laser-induced breakdown spectroscopy of potassium for in-situ geochronology on Mars
    Stipe, Christopher B.
    Guevara, Edward
    Brown, Jonathan
    Rossman, George R.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2012, 70 : 45 - 50
  • [6] Lifetime, size and emission of laser-induced plasmas for in-situ laser-induced breakdown spectroscopy on Earth, Mars and Moon
    Seel, Fabian
    Schroeder, Susanne
    Clave, Elise
    Dietz, Enrico
    Hansen, Peder Bagge
    Rammelkamp, Kristin
    Huebers, Heinz-Wilhelm
    ICARUS, 2025, 427
  • [7] In-situ diagnostics of chemically reacting flows using laser-induced breakdown spectroscopy
    Lee, TW
    Hegde, N
    Nonlinear Frequency Generation and Conversion: Materials, Devices, and Applications IV, 2005, 5710 : 130 - 137
  • [8] Laser-Induced Breakdown Spectroscopy (LIBS) - A tool for rapid in-situ elemental analysis
    Couris, S
    Mavromanolakis, A
    Fotakis, C
    SECOND GR-I INTERNATIONAL CONFERENCE ON NEW LASER TECHNOLOGIES AND APPLICATIONS, 1998, 3423 : 228 - 232
  • [9] Exploring laser-induced breakdown spectroscopy for nuclear materials analysis and in-situ applications
    Martin, Madhavi Z.
    Allman, Steve
    Brice, Deanne J.
    Martin, Rodger C.
    Andre, Nicolas O.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2012, 74-75 : 177 - 183
  • [10] In-situ measurement of hydrogen on airless planetary bodies using laser-induced breakdown spectroscopy
    Yumoto, Koki
    Cho, Yuichiro
    Kameda, Shingo
    Kasahara, Satoshi
    Sugita, Seiji
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2023, 205