Analysis and Control of Cascaded Energy Storage System for Energy Efficiency and Power Quality Improvement in Electrified Railways

被引:32
|
作者
Chen, Junyu [1 ]
Zhao, Yue [2 ]
Lin, Hongjian [3 ]
Wei, Yuqi [4 ]
Liu, Wenqiang [5 ,6 ]
Guo, Qi [2 ]
Li, Yunwei Ryan [7 ]
Mantooth, H. Alan [8 ]
机构
[1] Hong Kong Polytech Univ, Dept Elect & Elect Engn, Hong Kong, Peoples R China
[2] Inner Mongolia Elect Power Res Inst Co Ltd, Hohhot 010020, Peoples R China
[3] City Univ Hong Kong, Dept Elect Engn, Hong Kong, Peoples R China
[4] Xi An Jiao Tong Univ, Sch Elect Engn, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Peoples R China
[5] Hong Kong Polytech Univ, Shenzhen Res Inst, Hong Kong, Peoples R China
[6] Hong Kong Polytech Univ, Chinese Natl Rail Transit Electrificat & Automat, Hong Kong, Peoples R China
[7] Univ Alberta, Dept Elect & Comp Engn, Edmonton, AB T6G 2V4, Canada
[8] Univ Arkansas, Dept Elect Engn, Fayetteville, AR 72701 USA
来源
IEEE TRANSACTIONS ON TRANSPORTATION ELECTRIFICATION | 2024年 / 10卷 / 01期
基金
中国国家自然科学基金;
关键词
Reactive power; Rail transportation; Power quality; Energy storage; Load flow; Transformers; Energy efficiency; Electrified railway; energy efficiency; energy storage system (ESS); power flow control strategy; power quality; regenerative braking energy (RBE); MODULAR MULTILEVEL CONVERTER; CONTROL STRATEGY; CONDITIONER; STATE; MODEL;
D O I
10.1109/TTE.2023.3287891
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Energy-efficient and grid-friendly railway power system (RPS) is critical for the sustainable development of electrified railways. In this article, a cascaded energy storage system (CESS) is investigated for energy efficiency and power quality improvement of the RPS. First, the detailed operation principles of the CESS for multiple control objectives, including regenerative braking energy (RBE) utilization, reactive power compensation, and negative sequence current (NSC) suppression, are analyzed. On this basis, a hierarchical power flow control strategy is developed for achieving the power flow management and control of multiple objectives for CESS. Specifically, a multiobjective power flow management strategy is designed in the system layer to allocate the power references for the CESS under sufficient and insufficient capacity scenarios (ICS). In the sufficient capacity scenario (SCS), the power references are directly obtained by the operation principles. In the ICS, the power references are allocated through a three-stage optimization method considering the power shaving rate, grid power factor, and grid imbalance degree. Subsequently, the power references from the system layer are tracked in the converter layer to achieve power flow control. Finally, the effectiveness of the proposed hierarchical power flow control strategy is verified through experimental results. The results show that the proposed CESS can achieve superior performance on RBE utilization and power quality improvement under complex operating conditions in electrified railways.
引用
收藏
页码:1299 / 1313
页数:15
相关论文
共 50 条
  • [21] Power Quality Improvement in Renewable Energy Sources Based Power System Using DSTATCOM Supported by Battery Energy Storage System
    Mahela, Om Prakash
    Gupta, Priya
    Ali, Shoyab
    Gupta, Nitin
    2019 5TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENERGY SYSTEMS (ICEES 2019), 2019,
  • [22] Power quality enhancement in distribution network - control scheme of STATCOM with energy storage system
    Rafal, Krzysztof
    Kazmierkowski, Marian P.
    PRZEGLAD ELEKTROTECHNICZNY, 2012, 88 (12A): : 1 - 5
  • [23] A Method to Design Power Control System of Wayside Energy Storage System for Energy Saving in DC-electrified Railway
    Sato, Kota
    Kondo, Keiichiro
    Kobayashi, Hiroyasu
    Chida, Makoto
    2022 24TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'22 ECCE EUROPE), 2022,
  • [24] Grid Power Quality Improvement and Battery Energy Storage in Wind Energy Systems
    Mundackal, JohnsonAbraham
    Varghese, Alan C.
    Sreekala, P.
    Reshmi, V
    2013 ANNUAL INTERNATIONAL CONFERENCE ON EMERGING RESEARCH AREAS & 2013 INTERNATIONAL CONFERENCE ON MICROELECTRONICS, COMMUNICATIONS & RENEWABLE ENERGY (AICERA/ICMICR), 2013,
  • [25] Analysis of Wave Energy Converters and Impacts of Mechanical Energy Storage on Power Characteristic and System Efficiency
    Gao, Qiang
    Ertugrul, Nesimi
    Ding, Boyin
    PROCEEDINGS OF 2021 31ST AUSTRALASIAN UNIVERSITIES POWER ENGINEERING CONFERENCE (AUPEC), 2021,
  • [26] On Effect of Electrical Double Layer Capacitor Storage Devices on Power Quality in Power System with Electrified Railways
    Xu, Yizheng
    Chen, Xujiang
    Tian, Fang
    Peng, Hongying
    Yan, Shuchang
    2018 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2018, : 680 - 684
  • [27] Power Quality Problems in Autonomous Photovoltaic System with Energy Storage
    Becirovic, Vedad
    Helac, Vahid
    Hanjalic, Selma
    Smaka, Senad
    Samic, Hasnija
    2018 INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS, ELECTRICAL DRIVES, AUTOMATION AND MOTION (SPEEDAM), 2018, : 871 - 876
  • [28] Combined Operation of an Unified Power Quality Conditioner and a Superconducting Magnetic Energy Storage System for Power Quality Improvement
    Amaro, Nuno
    Casimiro, Luis
    Pina, Joao Murta
    Martins, Joao
    Ceballos, Jose M.
    TECHNOLOGICAL INNOVATION FOR CLOUD-BASED ENGINEERING SYSTEMS, 2015, 450 : 374 - 382
  • [29] Power quality improvement in distribution network using DSTATCOM with battery energy storage system
    Mahela, Om Prakash
    Shaik, Abdul Gafoor
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2016, 83 : 229 - 240
  • [30] Control of a wind energy conversion system equipped by a STACOM for power quality improvement
    Abdelouahed, Touhami
    Ahmed, Zidi Sid
    Hadjeri, Samir
    PROCEEDINGS OF 2016 8TH INTERNATIONAL CONFERENCE ON MODELLING, IDENTIFICATION & CONTROL (ICMIC 2016), 2016, : 115 - 121