IUPAC recommended experimental methods and data evaluation procedures for the determination of radical copolymerization reactivity ratios from composition data

被引:13
作者
Autzen, Anton A. A. [1 ]
Beuermann, Sabine [2 ]
Drache, Marco [2 ]
Fellows, Christopher M. [3 ]
Harrisson, Simon [4 ]
van Herk, Alex M. [5 ,6 ]
Hutchinson, Robin A. [7 ]
Kajiwara, Atsushi [8 ]
Keddie, Daniel J. [9 ]
Klumperman, Bert [10 ]
Russell, Gregory T. [11 ]
机构
[1] Tech Univ Denmark, Dept Hlth Technol, Lyngby, Denmark
[2] Tech Univ Clausthal, Inst Tech Chem, Clausthal Zellerfeld, Germany
[3] Univ New England, Sch Sci & Technol, Armidale, Australia
[4] Univ Bordeaux, CNRS, UMR 5629, LCPO,Bordeaux INP, Pessac, France
[5] Eindhoven Univ Technol, Dept Built Environm, Eindhoven, Netherlands
[6] Nanyang Technol Univ, Sch Mat Sci & Engn, Singapore, Singapore
[7] Queens Univ, Dept Chem Engn, Kingston, ON, Canada
[8] Nara Univ Educ, Dept Mat Sci, Nara, Japan
[9] Univ Nottingham, Sch Chem, Nottingham, England
[10] Univ Stellenbosch, Dept Chem & Polymer Sci, Stellenbosch, South Africa
[11] Univ Canterbury, Sch Phys & Chem Sci, Christchurch, New Zealand
关键词
ACRYLIC-ACID; MODEL; POLYMERIZATION; VISUALIZATION; ACRYLAMIDE; VARIABLES; BEHAVIOR; KINETICS; STYRENE; SUM;
D O I
10.1039/d4py00270a
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
The IUPAC working group on "Experimental Methods and Data Evaluation Procedures for the Determination of Radical Copolymerization Reactivity Ratios" recommends a robust method to determine reactivity ratios from copolymer composition data using the terminal model for copolymerization. The method is based on measuring conversion (X) and copolymer composition (F) of three or more copolymerization reactions at different initial monomer compositions (f0). Both low and high conversion experiments can be combined, or alternatively only low conversion experiments can be used. The method provides parameter estimates, but can also reveal deviations from the terminal model and the presence of systematic errors in the measurements. Special attention is given to error estimation in F and construction of the joint confidence interval for reactivity ratios. Previous experiments measuring f0 - F or f - X can also be analyzed with the IUPAC recommended method. The influence of systematic errors in the measurements on the reactivity ratio determinations is investigated, including ways to identify and mitigate such errors. The IUPAC method uses monomer composition, conversion, and copolymer composition to find reactivity ratios. Shown the optimal reactivity ratios in red and a 95% Confidence Interval in blue.
引用
收藏
页码:1851 / 1861
页数:11