Reducing effective radiation dose with improved image quality of abdominal computed tomography scans for overweight patients

被引:3
作者
Aljweber, Hayder A. [1 ]
Mamoun, Eslam [2 ]
Khouqeer, Ghada A. [3 ]
Elgarayhi, Ahmed [1 ]
Sallah, Mohammed [4 ]
机构
[1] Mansoura Univ, Fac Sci, Phys Dept, Mansoura 35516, Egypt
[2] Univ Pittsburgh, Radiat Safety Off, Pittsburgh, PA 15261 USA
[3] Imam Mohammad Ibn Saud Islamic Univ, Fac Sci, Phys Dept, Riyadh 11564, Saudi Arabia
[4] Univ Bisha, Coll Sci, Dept Phys, POB 344, Bisha 61922, Saudi Arabia
关键词
Hounsfield unit (HU); Noise; SNR; CNR; Effective dose (ED); LDCT; Body mass index (BMI); STATISTICAL ITERATIVE RECONSTRUCTION; OBESE-PATIENTS; TUBE VOLTAGE; DIAGNOSTIC-ACCURACY; MULTIDETECTOR CT; PERFORMANCE; PARAMETERS;
D O I
10.1016/j.jrras.2024.100868
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose: This work aimed to explore the effective radiation dose reduction for two Computed Tomography (CT) protocols for overweight and obese patients by using relevant physical techniques, all while obtaining acceptable image quality. Materials and methods: Two CT protocols (A: n = 50, 120 kV/190 +/- 60 mAs and B: n = 50, 100 kV/190 +/- 60 mAs) were used when imaging a total of 100 patients. For the two groups, the Computed Tomography Dose Index (CTDI) and Dose -Length Product (DLP) data were collected to calculate the effective dose (ED), as well as standard deviation (SD). The Hounsfield Unit (HU) details were collected to calculate the image quality coefficients noise (N), signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Results: Noise, SNR and CNR were significantly different (p -value <0.05) in group B against group A. CTDIvol (A: 12.5 mGy; B: 7.11 mGy, p -value <0.05), DLP (A: 516.11 mGy cm; B: 258.6 mGy cm, p -value <0.05) and the effective dose (A: 7.73 mSv; B: 3.87 mSv, p -value <0.05). Conclusions: The proposed CT protocol for overweight patients, especially for the abdominal area, included dose adjustment (reducing the voltage from 120 kV to 100 kV, mAs Auto). This reduced the exposure dose by half when compared to the standard protocol, with the reductions in CTDIvol, DLP, and ED all being statistically significant (p -values <0.05). The image quality also improved by 37% where changes in N, SNR and CNR were also statistically significant.
引用
收藏
页数:6
相关论文
共 37 条
[1]   Correlation of Chest CT and RT-PCR Testing for Coronavirus Disease 2019 (COVID-19) in China: A Report of 1014 Cases [J].
Ai, Tao ;
Yang, Zhenlu ;
Hou, Hongyan ;
Zhan, Chenao ;
Chen, Chong ;
Lv, Wenzhi ;
Tao, Qian ;
Sun, Ziyong ;
Xia, Liming .
RADIOLOGY, 2020, 296 (02) :E32-E40
[2]   Comparison of low dose and standard dose abdominal CT scan in body stuffers [J].
Bahrami-Motlagh, Hooman ;
Mahboubi-Fooladi, Zahra ;
Salevatipour, Babak ;
Hassanian-Moghaddam, Hossein ;
Mirhashemi, Seyyed Hadi .
CLINICAL TOXICOLOGY, 2018, 56 (05) :348-354
[3]   Improving Image Quality and Reducing Radiation Dose for Pediatric CT by Using Deep Learning Reconstruction [J].
Brady, Samuel L. ;
Trout, Andrew T. ;
Somasundaram, Elanchezhian ;
Anton, Christopher G. ;
Li, Yinan ;
Dillman, Jonathan R. .
RADIOLOGY, 2021, 298 (01) :180-188
[4]   PERSPECTIVES The Industry of CT Scanning [J].
Castillo, M. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (04) :583-585
[5]   Low-dose computed tomography of urolithiasis in obese patients: a feasibility study to evaluate image reconstruction algorithms [J].
Chang, De-Hua ;
Slebocki, Karin ;
Khristenko, Ekaterina ;
Herden, Jan ;
Salem, Johannes ;
Hokamp, Nils Grosse ;
Mammadov, Kamal ;
Hellmich, Martin ;
Kabbasch, Christoph .
DIABETES METABOLIC SYNDROME AND OBESITY-TARGETS AND THERAPY, 2019, 12 :439-445
[6]  
Chen GP, 2017, PHYS IMAG RADIAT ONC, V4, P6, DOI 10.1016/j.phro.2017.10.003
[7]   Performance of Iterative Reconstruction and Automated Tube Voltage Selection on the Image Quality and Radiation Dose in Abdominal CT Scans [J].
Desai, Gaurav S. ;
Orrego, Jorge M. Fuentes ;
Kambadakone, Avinash R. ;
Sahani, Dushyant V. .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (06) :897-903
[8]   Evaluation of Image Quality of Overweight and Obese Patients in CT Using High Data Rate Detectors [J].
Feldmane, Idana ;
Gampp, Christian ;
Hausmann, Daniel ;
Mavridis, Stylianos ;
Euler, Andre ;
Hefermehl, Lukas J. ;
Knoth, Friedrich ;
Kubik-Huch, Rahel A. ;
Nocito, Antonio ;
Niemann, Tilo .
IN VIVO, 2023, 37 (03) :1186-1191
[9]   Understanding, justifying, and optimizing radiation exposure for CT imaging in nephrourology [J].
Ferrero, Andrea ;
Takahashi, Naoki ;
Vrtiska, Terri J. ;
Krambeck, Amy E. ;
Lieske, John C. ;
McCollough, Cynthia H. .
NATURE REVIEWS UROLOGY, 2019, 16 (04) :231-244
[10]   Ultra-low dose CT abdomen and pelvis for the detection of acute abdominal pathology in the emergency room: initial experience from an academic hospital [J].
Gavrielli, Shlomo ;
Yan, Charles ;
Rogalla, Patrik ;
Anconina, Reut ;
Metser, Ur .
EMERGENCY RADIOLOGY, 2021, 28 (01) :15-21