Highly Efficient Year-Round Energy and Comfort Optimization of HVAC Systems in Electric City Buses

被引:2
作者
Widmer, Fabio [1 ]
Ritter, Andreas [1 ]
Achermann, Mathias [1 ]
Bueler, Fabian [1 ]
Bagajo, Joshua [1 ]
Onder, Christopher H. [1 ]
机构
[1] ETH, Inst Dynam Syst & Control, CH-8092 Zurich, Switzerland
来源
IFAC PAPERSONLINE | 2023年 / 56卷 / 02期
关键词
HVAC; model-based optimization; thermal comfort; electrified public transport; design sensitivities; Pareto optimality; radiant heating;
D O I
10.1016/j.ifacol.2023.10.715
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this paper, we present a novel approach to perform highly efficient numerical simulations of the heating, ventilation, and air-conditioning (HVAC) system of an electric city bus. The models for this simulation are based on the assumption of a steady-state operation. We show two approaches to obtain the minimum energy requirement for a certain thermal comfort criterion under specific ambient conditions. Due to the computationally efficient approach developed, we can evaluate the model on a large dataset of 7500 scenarios in various ambient conditions to estimate the year-round performance of the system subject to different comfort requirements. Compared to a heating strategy based on positive temperature coefficient (PTC) elements, we can thus show that a heat pump (HP) can reduce the annual mean power consumption by up to 60%. Ceiling-mounted radiant heating elements complementing a PTC heating system can reduce the annual mean power consumption by up to 10%, while they cannot improve the energy efficiency when used in conjunction with a HP. Finally, a broad sensitivity study reveals the fact that improving the HP's heating-mode coefficient of performance (COP) manifests the largest leverage in terms of mean annual power consumption. Moreover, the annual energy expenditure for cooling are around eight times smaller than those for heating. The case study considered thus reveals that the advantages of improving the COP of the cooling mode are significantly lower. Copyright (c) 2023 The Authors. This is an open access article under the CC BY-NC- ND license (https://creativecommons.org/licenses/by-nc-nd/4.0/)
引用
收藏
页码:10656 / 10663
页数:8
相关论文
共 3 条
  • [1] Optimization of the energy-comfort trade-off of HVAC systems in electric city buses based on a steady-state model
    Widmer, Fabio
    van Dooren, Stijn
    Onder, Christopher H.
    CONTROL ENGINEERING PRACTICE, 2025, 154
  • [2] Comfort-based fuzzy control optimization for energy conservation in HVAC systems
    Hussain, Sajid
    Gabbar, Hossam A.
    Bondarenko, Daniel
    Musharavati, Farayi
    Pokharel, Shaligram
    CONTROL ENGINEERING PRACTICE, 2014, 32 : 172 - 182
  • [3] Year-round energy-efficient multi-stage fresh air treatment system utilizing lake water as energy source
    Liang, Chenjiyu
    Wang, Wentao
    Wang, Huan
    Li, Xianting
    RENEWABLE ENERGY, 2025, 247