Development of CuO nanoparticles modified electrochemical sensor for detection of salbutamol

被引:1
作者
Delice, Tulay Koc [1 ]
Azem, Funda A. K. [2 ,3 ]
Ozdemir, Kazim [4 ]
Alpat, Senol [5 ]
机构
[1] Dokuz Eylul Univ, Grad Sch Nat & Appl Sci, Dept Nanosci & Nanoengn, Tinaztepe Campus, TR-35390 Izmir, Turkiye
[2] Dokuz Eylul Univ, Dept Met & Mat Engn, Tinaztepe Campus, TR-35390 Izmir, Turkiye
[3] Dokuz Eylul Univ, Grad Sch Nat & Appl Sci, Dept Nanosci & Nanoengn, TR-35390 Izmir, Turkiye
[4] Dokuz Eylul Univ, Grad Sch Nat & Appl Sci, Dept Biotechnol, Tinaztepe Campus, TR-35390 Izmir, Turkiye
[5] Dokuz Eylul Univ, Buca Fac Educ, Div Chem Educ, TR-35150 Izmir, Turkiye
关键词
CuO nanoparticles; electrochemical biosensor; metal oxide; salbutamol; VOLTAMMETRIC SENSOR; TOXIC RACTOPAMINE; CARBON ELECTRODE; QUANTUM DOTS; COPPER; IMMUNOSENSOR; IMMUNOASSAY; BEHAVIOR; SAMPLES; TIO2;
D O I
10.1088/2053-1591/ad3baf
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Metal oxide structures are being utilized in an increasing variety of applications. This study used cyclic and differential pulse voltammetry techniques to investigate the possible utilization of copper oxide (CuO) nanoparticles modified carbon paste electrode (CPE) for the redox reactions of salbutamol (SAL). The electrochemical performance of the SAL analyte in a complex matrix environment in Ventolin was evaluated in order to assess the appropriateness of the proposed sensor in a real sample environment. CuO nanoparticles were produced via a straightforward, cost-effective and efficient sol-gel method, and characterization studies of synthesized CuO nanoparticles were performed by scanning electron microscopy, x-ray Diffraction (XRD), and x-ray photoelectron spectroscopy. The synthesized CuO nanoparticles had a spherical shape and particle size was found to be 74 nm. The crystal size of the CuO particles was calculated to be 21.79 nm using the Debye-Scherrer equation. Under optimal conditions, differential pulse voltammetry demonstrated a linear response in the 50 nM to 100 mu M range, with a salbutamol detection limit of 50 nM (S/N = 3). The SAL concentration (R 2 = 0.9971) was found to have a good correlation coefficient. The reproducibility of the biosensor was investigated and evaluated with a relative standard deviation of 3% (n = 8). The storage stability of CuO modified CPE for two weeks was evaluated based on the response of DP current measured at intervals every two days. According to the measurement results, the modified electrode exhibited good stability and reproducibility while maintaining 80% of its stability. It is also a rapid and dependable sensor candidate with a measurement time of approximately 20 s. The developed electrode has been utilized successfully to determine doping material with improved performance.
引用
收藏
页数:15
相关论文
共 87 条
  • [31] Investigating the influence of Ni doping on the CuO thin films deposited via ultrasonic spray pyrolysis: Structural, optical and H2 gas sensing analyses
    Gulduren, Muhammed Emin
    Iskenderoglu, Demet
    Guney, Harun
    Gur, Emre
    Acar, Merve
    Karadeniz, Sibel Morkoc
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2023, 48 (02) : 828 - 839
  • [32] One Step Electrodeposition of Graphene-Au Nanocomposites for Highly Sensitive Electrochemical Detection of Salbutamol
    Guo, Xiu-Chun
    Wang, Hai-Hui
    Chen, Xuan-Jie
    Xia, Zhao-Yang
    Kang, Wen-Yi
    Zhou, Wen-Hui
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (02): : 861 - 875
  • [33] Electrochemical biosensor using SnO2 colloidal quantum wire for monitoring the interaction of microcystin antigen-antibody
    Huang, Qing
    Gu, RuiQin
    Zhao, Yunong
    Fu, Huibing
    Liu, Huan
    [J]. BIOELECTROCHEMISTRY, 2023, 154
  • [34] Effects of electrolyte variation on ammonia sensing temperature for BiVO4 sensing electrode in mixed potential gas sensor
    Islam, Md Shoriful
    Bhardwaj, Aman
    Mathur, Lakshya
    Kim, In-Ho
    Park, Jun-Young
    Song, Sun-Ju
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2022, 371
  • [35] Jabbar SM., 2016, ALKEJ, V12, P126, DOI [10.22153/kej.2016.07.001, DOI 10.22153/KEJ.2016.07.001]
  • [36] P-type CuO and Cu2O transistors derived from a sol-gel copper (II) acetate monohydrate precursor
    Jang, Jaewon
    Chung, Seungjun
    Kang, Hongki
    Subramanian, Vivek
    [J]. THIN SOLID FILMS, 2016, 600 : 157 - 161
  • [37] Jia S., 2016, Int. J. Curr. Res. Chem. Pharm. Sci, V3, P31, DOI [10.22192/ijcrcps.2016.03.12.006, DOI 10.22192/IJCRCPS.2016.03.12.006]
  • [38] Voltammetric sensor for tartrazine determination in soft drinks using poly (p-aminobenzenesulfonic acid)/zinc oxide nanoparticles in carbon paste electrode
    Karim-Nezhad, Ghasem
    Khorablou, Zeynab
    Zamani, Maryam
    Dorraji, Parisa Seyed
    Alamgholiloo, Mahdieh
    [J]. JOURNAL OF FOOD AND DRUG ANALYSIS, 2017, 25 (02) : 293 - 301
  • [39] Inkjet-printed graphene-poly(3,4-ethylenedioxythiophene):poly(styrene-sulfonate) modified on screen printed carbon electrode for electrochemical sensing of salbutamol
    Karuwan, Chanpen
    Sriprachuabwong, Chakrit
    Wisitsoraat, Anurat
    Phokharatkul, Ditsayut
    Sritongkham, Pornpimol
    Tuantranont, Adisorn
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2012, 161 (01): : 549 - 555
  • [40] Fabrication of TiO2 nanotubes on Ti6Al4V thin plate for non-enzymatic cholesterol biosensor
    Kumar, Bittu
    Soni, Tikam Chand
    Sinha, Sudip K.
    [J]. MATERIALS TODAY-PROCEEDINGS, 2022, 66 : 562 - 565