Development of CuO nanoparticles modified electrochemical sensor for detection of salbutamol

被引:1
作者
Delice, Tulay Koc [1 ]
Azem, Funda A. K. [2 ,3 ]
Ozdemir, Kazim [4 ]
Alpat, Senol [5 ]
机构
[1] Dokuz Eylul Univ, Grad Sch Nat & Appl Sci, Dept Nanosci & Nanoengn, Tinaztepe Campus, TR-35390 Izmir, Turkiye
[2] Dokuz Eylul Univ, Dept Met & Mat Engn, Tinaztepe Campus, TR-35390 Izmir, Turkiye
[3] Dokuz Eylul Univ, Grad Sch Nat & Appl Sci, Dept Nanosci & Nanoengn, TR-35390 Izmir, Turkiye
[4] Dokuz Eylul Univ, Grad Sch Nat & Appl Sci, Dept Biotechnol, Tinaztepe Campus, TR-35390 Izmir, Turkiye
[5] Dokuz Eylul Univ, Buca Fac Educ, Div Chem Educ, TR-35150 Izmir, Turkiye
关键词
CuO nanoparticles; electrochemical biosensor; metal oxide; salbutamol; VOLTAMMETRIC SENSOR; TOXIC RACTOPAMINE; CARBON ELECTRODE; QUANTUM DOTS; COPPER; IMMUNOSENSOR; IMMUNOASSAY; BEHAVIOR; SAMPLES; TIO2;
D O I
10.1088/2053-1591/ad3baf
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Metal oxide structures are being utilized in an increasing variety of applications. This study used cyclic and differential pulse voltammetry techniques to investigate the possible utilization of copper oxide (CuO) nanoparticles modified carbon paste electrode (CPE) for the redox reactions of salbutamol (SAL). The electrochemical performance of the SAL analyte in a complex matrix environment in Ventolin was evaluated in order to assess the appropriateness of the proposed sensor in a real sample environment. CuO nanoparticles were produced via a straightforward, cost-effective and efficient sol-gel method, and characterization studies of synthesized CuO nanoparticles were performed by scanning electron microscopy, x-ray Diffraction (XRD), and x-ray photoelectron spectroscopy. The synthesized CuO nanoparticles had a spherical shape and particle size was found to be 74 nm. The crystal size of the CuO particles was calculated to be 21.79 nm using the Debye-Scherrer equation. Under optimal conditions, differential pulse voltammetry demonstrated a linear response in the 50 nM to 100 mu M range, with a salbutamol detection limit of 50 nM (S/N = 3). The SAL concentration (R 2 = 0.9971) was found to have a good correlation coefficient. The reproducibility of the biosensor was investigated and evaluated with a relative standard deviation of 3% (n = 8). The storage stability of CuO modified CPE for two weeks was evaluated based on the response of DP current measured at intervals every two days. According to the measurement results, the modified electrode exhibited good stability and reproducibility while maintaining 80% of its stability. It is also a rapid and dependable sensor candidate with a measurement time of approximately 20 s. The developed electrode has been utilized successfully to determine doping material with improved performance.
引用
收藏
页数:15
相关论文
共 87 条
  • [21] Exploring the structural and electrochemical sensing of wide bandgap calcium phosphate/CuxFe3-xO4 core-shell nanoceramics for H2O2 detection
    Elzwawy, Amir
    Mansour, A. M.
    Magar, Hend S.
    Hammad, Ali B. Abou
    Hassan, Rabeay Y. A.
    Nahrawy, Amany M. El
    [J]. MATERIALS TODAY COMMUNICATIONS, 2022, 33
  • [22] Study on the electrochemical behavior and differential pulse voltammetric determination of rhein using a nanoparticle composite film-modified electrode
    Fei, Junjie
    Peng, Yan
    Tan, Hongyan
    Chen, Xiaoming
    Yang, Jing
    Li, Junan
    [J]. BIOELECTROCHEMISTRY, 2007, 70 (02) : 369 - 374
  • [23] Determination of salbutamol in syrups by capillary electrophoresis with contactless conductivity detection (CE-C4D)
    Felix, FS
    Quintino, MSM
    Carvalho, AZ
    Coelho, LHG
    do Lago, CL
    Angnes, L
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 40 (05) : 1288 - 1292
  • [24] Determination of Trace Tl(I) by Differential Pulse Anodic Stripping Voltammetry Using a Novel Modified Carbon Paste Electrode
    Ghanei-Motlagh, Masoud
    Baghayeri, Mehdi
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2020, 167 (06)
  • [25] Effects of inhaled salbutamol in exercising non-asthmatic athletes
    Goubault, C
    Perault, MC
    Leleu, E
    Bouquet, S
    Legros, P
    Vandel, B
    Denjean, A
    [J]. THORAX, 2001, 56 (09) : 675 - 679
  • [26] Effect of graphite and metallic impurities of C60 fullerene on determination of salbutamol in biological fluids
    Goyal, Rajendra N.
    Kaur, Davinder
    Singh, Sudhanshu P.
    Pandey, Ashish K.
    [J]. TALANTA, 2008, 75 (01) : 63 - 69
  • [27] Fast determination of salbutamol, abused by athletes for doping, in pharmaceuticals and human biological fluids by square wave voltammetry
    Goyal, Rajendra N.
    Oyama, Munetaka
    Singh, Sudhanshu P.
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2007, 611 (1-2) : 140 - 148
  • [28] Single-Walled-Carbon-Nanotube-Modified Pyrolytic Graphite Electrode Used as a Simple Sensor for the Determination of Salbutamol in Urine
    Goyal, Rajendra N.
    Bishnoi, Sunita
    Agrawal, Bharati
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMISTRY, 2011, 2011
  • [29] Simultaneous voltammetric determination of prednisone and prednisolone in human body fluids
    Goyal, Rajendra N.
    Bishnoi, Sunita
    [J]. TALANTA, 2009, 79 (03) : 768 - 774
  • [30] Methods of Synthesis, Properties and Biomedical Applications of CuO Nanoparticles
    Grigore, Madalina Elena
    Biscu, Elena Ramona
    Holban, Alina Maria
    Gestal, Monica Cartelle
    Grumezescu, Alexandru Mihai
    [J]. PHARMACEUTICALS, 2016, 9 (04)