Experimental study on soil temperature field of earth-air heat exchanger in solar greenhouse

被引:0
作者
Li J. [1 ]
Du Z. [1 ]
Tian H. [2 ]
机构
[1] College of Civil Engineering, Taiyuan University of Technology, Taiyuan
[2] Gas Planning and Design Institute of Shanxi Province, Taiyuan
来源
Taiyangneng Xuebao/Acta Energiae Solaris Sinica | 2021年 / 42卷 / 12期
关键词
Geothermal energy; Heat exchanger; Soil testing; Temperature field; Thermal disturbance radius;
D O I
10.19912/j.0254-0096.tynxb.2019-1357
中图分类号
学科分类号
摘要
In order to study the variation law of the soil temperature field around the pipeline of the earth-air heat exchanger(EAHE) with air temperature and flow rate in the pipeline, the soil temperature field around the pipeline was tested for an actual solar greenhouse in Taiyuan. Results show that the heat transfer from air in pipe to soil, the temperature amplitude and heat affected zone of soil increase with the air velocity changing from 0.5 m/s to 4.5 m/s. When the temperature of inlet air changes in a daily cycle, the soil changes in a same period. But the response of soil temperature had attenuation and delay in different degree for different distance from the soil to pipeline center. The thermal disturbance radius in the soil is less than 0.5 m for the periodic heat flux. The soil temperature fluctuations in horizontal and vertical directions were similar but with some differences in terms of decay rate and time lag. © 2021, Solar Energy Periodical Office Co., Ltd. All right reserved.
引用
收藏
页码:375 / 380
页数:5
相关论文
共 17 条
[1]  
YAN T T, DU Z Y., Study on the heat and moisture transfer principles of soil field surrounding the soil-air heat exchanger in solar greenhouse, Journal of engineering thermophysics, 39, 2, pp. 434-441, (2018)
[2]  
VITT R, WEBER L, ZOLLITSCH W, Et al., Modelled performance of energy saving air treatment devices to mitigate heat stress for confined livestock buildings in Central Europe, Biosystems engineering, 164, pp. 85-97, (2017)
[3]  
CONGEDO P M, LORUSSO C, BAGLIVO C, Et al., Experimental validation of horizontal air-ground heat exchangers (HAGHE) for ventilation systems, Geothermics, 80, pp. 78-85, (2019)
[4]  
ZHAO Y J, LI R Y, JI C F, Et al., Parametric study and design of an earth-air heat exchanger using model experiment for memorial heating and cooling, Applied thermal engineering, 148, pp. 838-845, (2019)
[5]  
LI H, NI L, LIU G, Et al., Feasibility study on applications of an earth-air heat exchanger (EAHE) for preheating fresh air in severe cold regions, Renewable energy, 133, pp. 1268-1284, (2019)
[6]  
WU J T, ZHAO B, ZHAN W X, Et al., Test study of a building-fresh air-system using earth-air heat exchangers, Journal of Hebei University of Technology, 43, 1, pp. 82-87, (2014)
[7]  
ELMINSHAWY N A S, MOHAMED A M I, MORAD K, Et al., Performance of PV panel coupled with geothermal air cooling system subjected to hot climatic, Applied thermal engineering, 148, pp. 1-9, (2019)
[8]  
WANG Z B, DU Z Y., Heat and moisture environment under the action of earth-to-air heat exchanger in solar greenhouse, Science technology and engineering, 18, 23, pp. 297-303, (2018)
[9]  
HEPBASLI A., Low exergy modelling and performance analysis of greenhouses coupled to closed earth-to-air heat exchangers (EAHEs), Energy and buildings, 64, pp. 224-230, (2013)
[10]  
MONGKON S, THEPA S, NAMPRAKAI P, Et al., Cooling performance and condensation evaluation of horizontal earth tube system for the tropical greenhouse, Energy and buildings, 66, pp. 104-111, (2013)