Influence of design variables on seismic performance of unitized curtain walls: a parametric experimental study

被引:4
作者
Bianchi, Simona [1 ]
Lori, Guido [2 ]
Hayez, Valerie [3 ]
Overend, Mauro [1 ]
Manara, Giampiero [2 ]
机构
[1] Delft Univ Technol, Delft, Netherlands
[2] Permasteelisa Grp, Vittorio Veneto, Italy
[3] Dow Silicones, Seneffe, Belgium
关键词
Glazed facades; Unitized curtain walls; Seismic design; Experimental testing; Statistical analysis; FRAGILITY; GLASS;
D O I
10.1007/s40940-024-00255-2
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Creating safer and more resilient building facades has become a primary concern in contemporary design, particularly in earthquake-prone regions, where there is a potentially high impact on financial, social and environmental losses. Glazed curtain wall systems are widely used in modern architecture. Yet, despite decades of research efforts aimed at enhancing the understanding of their seismic behaviour, it is not clear how design choices affect the response of glazed facades. This is crucial given the wide range of glass, framing and joint variations that are at our disposal. With a focus on unitized curtain walls, this paper provides insights into the influence of design variables on fa & ccedil;ade seismic response by means of an extensive experimental campaign and an associated parametric study to test alternative designs under both quasi-static and dynamic loading conditions. The variables considered included variations in unit dimensions, glass and joint aspect ratios, joint and framing detailing, and support conditions. This research delves into a statistical analysis of the experimental results, in order to define parameters such as glass and fa & ccedil;ade unit rotations, frame elongations and distortions, utilization factors at different intensity levels. The results provide insights that guide fa & ccedil;ade design decisions for achieving desired seismic performance levels.
引用
收藏
页码:165 / 184
页数:20
相关论文
共 31 条
[1]  
[Anonymous], 2009, C140109 ASTM
[2]  
[Anonymous], 2004, EUROCODE 8 DESIGN ST
[3]  
[Anonymous], 2009, AAMA501409
[4]  
[Anonymous], 2018, 090010000404 EAD EOT
[5]  
[Anonymous], 2012, ETAG0021 EOTA
[6]  
[Anonymous], 2016, 117052004 NZS
[7]  
[Anonymous], 2022, 13830 UNI EN EUR COM
[8]  
[Anonymous], 2010, Minimum Design Loads for Buildings and Other Structures
[9]  
[Anonymous], 2009, AAMA501609
[10]   EXPERIMENTAL INVESTIGATION INTO THE SEISMIC FRAGILITY OF A COMMERCIAL GLAZING SYSTEM [J].
Arifin, Fransiscus A. ;
Sullivan, Timothy J. ;
Dhakal, Rajesh P. .
BULLETIN OF THE NEW ZEALAND SOCIETY FOR EARTHQUAKE ENGINEERING, 2020, 53 (03) :144-149