separation characteristics test of corrugated plate in gas-liquid separation flash skid

被引:0
作者
Ma H. [1 ,2 ]
Ding R. [1 ]
Han X. [2 ]
Wang L. [2 ]
机构
[1] School of Civil Engineering and Architecture, East ChinaJiaotong University, Nanchang
[2] School of Civil Engineering, Lanzhou University of Technology, Lanzhou
来源
Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology | 2023年 / 55卷 / 08期
关键词
corrugated plate; gas-liquid separation flash skid; orthogonal test; pressure drop; separation efficiency;
D O I
10.11918/202205082
中图分类号
学科分类号
摘要
In the process of natural gas exploitation, liquid water deposition will seriously threaten the gas transmission pipeline. As such, the gas-liquid separation equipment is widely used in the natural gas gathering system. To investigate the separation characteristics of the corrugated plate, which is viewed as an important separation element in the liquid separation side of the gas-liquid separation flash skid, an experimental platform for exploring the separation characteristics of baffles is constructed, coupled with the orthogonal experiment designed for different types of corrugated plate. The separation efficiency and pressure drop of the corrugated plate are taken as the test indexes. The main influencing factors and the best combination scheme are determined by analyzing the influence of the internal components at the liquid separation side on the separation performance under multiple working conditions at room temperature. The results show that the separation efficiency proves to be the best when the horizontal trapezoidal or honeycomb corrugated plate, deflector structural parameters of 180/102/105 or 120/102/105, liquid gas ratio of 2.083% ~ 2.917% and closed connecting pipe are combined. The corrugated plate type is seen as a vital factor affecting the separation efficiency. The pressure drop would be the smallest in the whole gas-liquid separation process when the honeycomb or vertical trapezoid corrugated plate, the deflector structural parameters of 180/102/105 or 120/102/105, the liquid-gas ratio of 3.750% ~ 4.583% and the closed connecting pipe are integrated. The above four factors exert no significant influence on the pressure drop. © 2023 Harbin Institute of Technology. All rights reserved.
引用
收藏
页码:143 / 150
页数:7
相关论文
共 18 条
[1]  
ZAHNG Yongzhao, LI Yilang, ZHANG Ximin, Et al., Experimental research on impact type inertia separator with fluted tubes, Power Engineering, 9, 6, (1989)
[2]  
ZHU Yuqin, Experimental study on inertial separation of small sized water droplets in a gas-liquid two-phase mixture, Power Equipment, 19, 3, (2005)
[3]  
XIA Pengli, YANG Jing, Performance analysis and research development of wave-plate mist eliminator, Process Equipment & Piping, 50, 6, (2013)
[4]  
MONAT J P, MCNULTY K J, MICHELSON I, Et al., Accurate evaluation of chevron mist eliminators, Chemical Engineering Progress, 82, (1986)
[5]  
MCNUL TY K J, MONAT J, HANSEN O V., Performance of commercial chevron mist eliminators, Chemical Engineering Progress, 83, (1987)
[6]  
YANG Jiandong, ZHAO Peng, JIA Haihai, Optimal design of corrugated plate oil-gas separator based on discrete phase model, China Plant Engineering, 6, (2017)
[7]  
LANG Fangnian, CHEN Jinyu, WU Jianwei, Et al., Study on demisting performance of corrugated plate desulfurization demister, Machine Tool & Hydraulics, 31, 5, (2003)
[8]  
FRIEDLANDER S K, JOHNSTONE H F., Deposition of suspended particles from turbulent gas streams, Industrial & Engineering Chemistry, 49, 7, (1957)
[9]  
KALLIO G A, REEKS M W., A numerical-simulation of particle deposition in turbulent boundary layers, International Journal of Multiphase Flow, 15, 3, (1989)
[10]  