iRing: a program for two-dimensional powder diffraction image integration with automatic calibration

被引:0
|
作者
Sun, Xiaowei [1 ,2 ,3 ,4 ]
Feng, Zhenjie [1 ,2 ,3 ,4 ]
Lv, Binfeng [1 ,2 ,3 ,4 ]
Cao, Jian [1 ,3 ,4 ]
Chang, Shihui [1 ,3 ,4 ]
Dong, Cheng [5 ]
机构
[1] Shanghai Univ, Mat Genome Inst, Shanghai 200444, Peoples R China
[2] Zhejiang Lab, Hangzhou 311100, Peoples R China
[3] Shanghai Laue Sci & Technol Inst, Shanghai 200444, Peoples R China
[4] Shanghai Univ, Dept Phys, Shanghai Key Lab High Temp Superconductors, Shanghai 200444, Peoples R China
[5] Peking Univ Shenzhen Grad Sch, Sch Adv Mat, Shenzhen 518055, Peoples R China
来源
JOURNAL OF APPLIED CRYSTALLOGRAPHY | 2024年 / 57卷 / Pt 2期
基金
中国国家自然科学基金;
关键词
image detectors; Hough transform; calibration; REDUCTION;
D O I
10.1107/S1600576724001936
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
iRing is a processing program developed for the more convenient processing of two-dimensional diffraction images collected by image detectors. During the calibration process, iRing uses the Hough transform to achieve automatic peak finding and calibration. The speed of calibration is greatly improved and the difficulty of calibration is reduced. iRing also provides many supporting functions to help process data.
引用
收藏
页码:567 / 571
页数:5
相关论文
共 50 条
  • [31] TWO-DIMENSIONAL PHASE RETRIEVAL FROM IMAGE AND DIFFRACTION PATTERNS IN ELECTRON-MICROSCOPES
    SHAO, ZF
    JIYE, XM
    OPTIK, 1985, 71 (01): : 15 - 22
  • [32] Automatic needle segmentation in three-dimensional ultrasound images using two orthogonal two-dimensional image projections
    Ding, MY
    Cardinal, HN
    Fenster, A
    MEDICAL PHYSICS, 2003, 30 (02) : 222 - 234
  • [33] Accurate and traceable calibration of two-dimensional gratings
    Dai, Gaoliang
    Pohlenz, Frank
    Dziomba, Thorsten
    Xu, Min
    Diener, Alexander
    Koenders, Ludger
    Danzebrink, Hans-Ulrich
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2007, 18 (02) : 415 - 421
  • [34] CALIBRATION OF A TWO-DIMENSIONAL HYDRODYNAMICS MODEL.
    Chu, Wen-Sen
    Yeh, William W.-G.
    1600, (09):
  • [35] Two-dimensional transforms for device color calibration
    Bala, R
    Monga, V
    Sharma, G
    Van de Capelle, JP
    COLOR IMAGING IX: PROCESSING, HARDCOPY, AND APPLICATIONS, 2004, 5293 : 250 - 261
  • [36] Calibration of a two-dimensional ionization chamber array
    Lemke, M
    Poppe, B
    Kollhoff, R
    Rubach, A
    Temmeseld, A
    STRAHLENTHERAPIE UND ONKOLOGIE, 2002, 178 : 69 - 69
  • [37] Plate calibration methods for two-dimensional stages
    Fu, JY
    Zhang, GX
    Hocken, R
    PROCEEDINGS OF THE FIFTEENTH ANNUAL MEETING OF THE AMERICAN SOCIETY FOR PRECISION ENGINEERING, 2000, : 469 - 472
  • [38] Two-dimensional calibration artifact and measurement methodology
    Silver, RM
    Doiron, T
    Penzes, W
    Kornegay, E
    Fox, S
    Takac, M
    Rathjen, S
    Owens, D
    METROLOGY, INSPECTION, AND PROCESS CONTROL FOR MICROLITHOGRAPHY XIII, PTS 1 AND 2, 1999, 3677 : 123 - 138
  • [39] Integration techniques for surface X-ray diffraction data obtained with a two-dimensional detector
    Drnec, Jakub
    Zhou, Tao
    Pintea, Stelian
    Onderwaater, Willem
    Vlieg, Elias
    Renaud, Gilles
    Felici, Roberto
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2014, 47 : 365 - 377
  • [40] Integration techniques for surface X-ray diffraction data obtained with a two-dimensional detector
    Drnec, J. (drnec@esrf.fr), 1600, International Union of Crystallography, 5 Abbey Road, Chester, CH1 2HU, United Kingdom (47):