On Medium Frequency Differential Mode Resonance Effects in Doubly Fed Induction Machines

被引:1
|
作者
Barnklau H. [1 ]
Proske J. [1 ]
机构
[1] Vem Sachsenwerk GmbH, Dresden
来源
IEEE Open Journal of Industry Applications | 2022年 / 3卷
关键词
AC generators; electric machines; frequency response; induction generators; pulse width modulated power converters; resonance; rotating machine insulation; switching transients;
D O I
10.1109/OJIA.2022.3157675
中图分类号
学科分类号
摘要
During synchronization phase of a doubly fed induction machine prototype abnormal high voltages were recorded at stator terminals. By evaluating the measured curves, and the frequency response of a similar machine, these overvoltages could be traced back to differential mode resonance effects within the machine itself. The effect of differential mode resonance is not restricted to doubly fed induction machines but also occurs in other machine types such as squirrel cage induction machines. If not considered in the insulation design, such abnormal voltages will lead to a premature ageing of the insulation. Depending on the operating conditions, premature failures may occur. The measured data presented in the article give an illustrative example what could happen if windings of electric machines are excited near series resonance frequency. As the occurence of this effect becomes more probable the higher the switching frequency of the converter, it is thoroughly important to be aware of it. © 2020 IEEE.
引用
收藏
页码:56 / 65
页数:9
相关论文
共 12 条
  • [1] On Medium Frequency Differential Mode Resonance Effects in Electric Machines
    Barnklau H.
    Harnisch M.
    Proske J.
    IEEE Open Journal of Industry Applications, 2021, 2 : 310 - 319
  • [2] Effects of inverter supply on the iron loss characteristics of doubly fed induction machines
    Handgruber, Paul
    Schernthanner, Simon
    Biro, Oszkar
    Stermecki, Andrej
    Ofner, Georg
    COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2015, 34 (05) : 1460 - 1474
  • [3] Frequency control strategy of doubly-fed induction generators considering frequency deviation
    Xu Y.
    Yang D.
    Zheng T.
    Zhang X.
    Hua L.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2022, 43 (10): : 229 - 235
  • [4] Doubly Fed Induction Machines Diagnosis Based on Signature Analysis of Rotor Modulating Signals
    Stefani, Andrea
    Yazidi, Amine
    Rossi, Claudio
    Filippetti, Fiorenzo
    Casadei, Domenico
    Capolino, Gerard-Andre
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2008, 44 (06) : 1711 - 1721
  • [5] A Topology for Multiple Generation System With Doubly Fed Induction Machines and Indirect Matrix Converter
    Pena, Ruben
    Cardenas, Roberto
    Reyes, Eduardo
    Clare, Jon
    Wheeler, Patrick
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (10) : 4181 - 4193
  • [6] Sub-synchronous resonance mitigation scheme by stator side converter in doubly fed induction generator
    Dong X.
    Xie X.
    Tian X.
    Tian, Xu (tianxu516@163.com), 2016, Science Press (42): : 2785 - 2791
  • [7] Higher Mode Frequency Effects on Resonance in Machinery, Structures
    Leishear, Robert A.
    PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE 2010, VOL 3, 2010, : 945 - 955
  • [8] Power system frequency response from fixed speed and doubly fed induction generator based wind turbines
    Holdsworth, L
    Ekanayake, JB
    Jenkins, N
    WIND ENERGY, 2004, 7 (01) : 21 - 35
  • [9] Comparison of the response of doubly fed and fixed-speed induction generator wind turbines to changes in network frequency
    Ekanayake, J
    Jenkins, N
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2004, 19 (04) : 800 - 802
  • [10] Frequency response Analysis of Doubly-Fed Variable Speed Pumped Storage Unit Based on Simplified Mode
    Gao, Chunyang
    Ge, Ye
    Yu, Xiangyang
    Nan, Haipeng
    Zhao, Haoran
    Wu, Luochang
    2024 5TH INTERNATIONAL CONFERENCE ON MECHATRONICS TECHNOLOGY AND INTELLIGENT MANUFACTURING, ICMTIM 2024, 2024, : 610 - 615