Calibration of flow differential pressure coefficients on pump-turbine by thermodynamic method

被引:0
作者
Zhang W. [1 ]
Xu H. [1 ]
Liu W. [1 ]
Hu X. [1 ]
Liu J. [2 ]
机构
[1] Shisanling Pumped Storage Power Plant of State Grid Xinyuan Company Ltd., Beijing
[2] China Institute of Water Resources and Hydropower Research, Beijing
关键词
Differential pressure; Pump-turbine; Thermodynamics; Winter-Kenndy;
D O I
10.1186/s42162-024-00365-9
中图分类号
学科分类号
摘要
On-line monitoring of flow rate is rather important to evaluate the water consumption of the pump-turbine and the overall efficiency of the pumped storage station. Flow rate can be worked out based on the flow differential pressure measured in the flow passage and coefficients determined on model test. But the coefficients must be calibrated to obtain the reliable flow rate. As thermodynamic method is a common way to measure the discharge of prototype pump-turbine, site test is carried out on a vertical pump-turbine with 600 m rated head to calibrated the coefficients in this paper. Measuring devices are designed to satisfy both the turbine and pump operating conditions, and test results of flow rate at both turbine and pump operating conditions are presented and show that the calibrated coefficients are different to the predicted values. The calibrated results indicate the importance of site calibration on prototype turbine to ensure the monitoring validity on real-time flow rate. © The Author(s) 2024.
引用
收藏
相关论文
共 20 条
[1]  
Cao D.F., Zhou Y., Pan L.P., Et al., Efficiency measurement on horizontal Pelton turbine by thermodynamic method, IOP Conf Ser: Earth Environ Sci, 774, (2021)
[2]  
Chai P., Thermodynamic analysis of a Pelton turbine for small-scale hydropower plants, Appl Mech Mater, 537, pp. 84-88, (2014)
[3]  
Gans L.H.A., Trivedi C., Storli P., Et al., An experimental and numerical study of a three-lobe pump for pumped hydro storage applications, J Phys: Conf Ser, 2629, (2023)
[4]  
Gao T.Y., (, Hubei Electric Power, 25, 3, pp. 25-27, (2001)
[5]  
Guo J., Liu W., Determination of flow coefficients of spiral case, . Mechanical &Electrical Technique of Hydropower Station, 1994, 4, pp. 28-32, (1994)
[6]  
Ilinca A., Ilinca G., Thermodynamic analysis of small-scale hydrokinetic turbines, Energies, 10, 12, (2017)
[7]  
Javadian A., Gaurav K., Computational analysis of a francis turbine under different operating conditions, Journal of Physics: Conference Series, 1665, 1, (2020)
[8]  
Kerschberger P., Gehrer A., Hydraulic development of high specific-speed pump-turbines by means of an inverse design method, numerical flow-simulation (CFD) and model testing, IOP Conf Ser: Earth Environ Sci, 12, (2010)
[9]  
Merry S.L., Thew M.T., Evaluation of a thermodynamic method for efficiency measurements on a low-pressure pump in water and mercury, J Phys E: Sci Instrum, 17, (1984)
[10]  
Shen J.C., Zhou J., Review and optimization of main parameters of pump turbine in Xiangshuijian pumped-storage power station, IOP Conf Ser: Earth Environ Sci, 163, (2018)