A fully automatic parenchyma extraction method for MRI T2*relaxometry of iron loaded liver in transfusion-dependent patients

被引:0
作者
Lian, Zifeng [1 ,2 ,3 ,4 ,5 ,6 ]
Lu, Qiqi [1 ,2 ,3 ,4 ,5 ,6 ]
Lin, Bingquan [7 ]
Chen, Lingjian [8 ]
Gong, Jian [1 ]
Hu, Qiugen [1 ,8 ]
Wang, Huafeng [1 ,8 ]
Feng, Yanqiu [1 ,2 ,3 ,4 ,5 ,6 ,8 ]
机构
[1] Southern Med Univ, Sch Biomed Engn, Guangzhou, Peoples R China
[2] Southern Med Univ, Guangdong Prov Key Lab Med Image Proc, Guangzhou, Peoples R China
[3] Southern Med Univ, Guangdong Prov Engn Lab Med Imaging & Diagnost Tec, Guangzhou, Peoples R China
[4] Southern Med Univ, Guangdong Hong Kong Macao Greater Bay Area Ctr Bra, Guangdong Hong Kong Macao Greater Bay Area, Guangzhou, Peoples R China
[5] Southern Med Univ, Key Lab Mental Hlth, Minist Educ, Guangzhou, Peoples R China
[6] Southern Med Univ, Guangdong Hong Kong Joint Lab Psychiat Disorders, Guangzhou, Peoples R China
[7] Southern Med Univ, Nanfang Hosp, Dept Med Imaging Ctr, Guangzhou, Peoples R China
[8] Southern Med Univ, Shunde Hosp, Peoples Hosp Shunde 1, Dept Radiol, Foshan, Peoples R China
基金
中国国家自然科学基金;
关键词
Magnetic resonance imaging; T2*relaxometry; Liver iron loaded; Deep learning; Segmentation; SICKLE-CELL-DISEASE; WHOLE-LIVER; QUANTIFICATION; OVERLOAD; THALASSEMIA; RELAXOMETRY; THERAPY; STORES;
D O I
10.1016/j.mri.2024.02.017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop a fully automatic parenchyma extraction method for the T2* relaxometry of iron overload liver. Methods: A retrospective multicenter collection of liver MR examinations from 177 transfusion-dependent patients was conducted. The proposed method extended a semiautomatic parenchyma extraction algorithm to a fully automatic approach by introducing a modified TransUNet on the R2* (1/T2*) map for liver segmentation. Axial liver slices from 129 patients at 1.5 T were allocated to training (85%) and internal test (15%) sets. Two external test sets separately included 1.5 T data from 20 patients and 3.0 T data from 28 patients. The final T2* measurement was obtained by fitting the average signal of the extracted liver parenchyma. The agreement between T2* measurements using fully and semiautomatic parenchyma extraction methods was assessed using coefficient of variation (CoV) and Bland-Altman plots. Results: Dice of the deep network-based liver segmentation was 0.970 +/- 0.019 on the internal dataset, 0.960 +/- 0.035 on the external 1.5 T dataset, and 0.958 +/- 0.014 on the external 3.0 T dataset. The mean difference bias between T2* measurements of the fully and semiautomatic methods were separately 0.12 (95% CI: -0.37, 0.61) ms, 0.04 (95% CI: -1.0, 1.1) ms, and 0.01 (95% CI: -0.25, 0.23) ms on the three test datasets. The CoVs between the two methods were 4.2%, 4.8% and 2.0% on the internal test set and two external test sets. Conclusions: The developed fully automatic parenchyma extraction approach provides an efficient and operatorindependent T2* measurement for assessing hepatic iron content in clinical practice.
引用
收藏
页码:18 / 26
页数:9
相关论文
共 50 条
[41]   Correlation of serum ferritin levels with hepatic MRI T2 and liver iron concentration in nontransfusion beta-thalassemia intermediate patients: A contemporary issue [J].
Karimi, Mehran ;
Amirmoezi, Fatemeh ;
Haghpanah, Sezaneh ;
Ostad, Seyedpouria ;
Lotfi, Mehrzad ;
Sefidbakht, Sepideh ;
Rezaian, Shahed .
PEDIATRIC HEMATOLOGY AND ONCOLOGY, 2017, 34 (05) :292-297
[42]   Hepatic and cardiac iron load as determined by MRI T2*in patients with congenital dyserythropoietic anemia type I [J].
Asleh, Mahdi ;
Levitas, Aviva ;
Daniel, Sharon ;
Abu-Quider, Abed ;
Ben-Harosh, Miriam ;
Kapelushnik, Joseph .
ANNALS OF HEMATOLOGY, 2020, 99 (11) :2507-2512
[43]   The relationship between myocardial and hepatic T2 and T2*at 1.5T and 3T MRI in normal and iron-overloaded patients [J].
Kritsaneepaiboon, Supika ;
Ina, Natee ;
Chotsampancharoen, Thirachit ;
Roymanee, Supaporn ;
Cheewatanakornkul, Sirichai .
ACTA RADIOLOGICA, 2018, 59 (03) :355-362
[44]   Association of HFE Gene Mutations With Serum Ferritin Level and Heart and Liver Iron Overload in Patients With Transfusion-dependent Beta-Thalassemia [J].
Zekavat, Omid Reza ;
Jahromi, Mahshid Zareian ;
Haghpanah, Sezaneh ;
Jahromi, Zahra Kargar ;
Cohan, Nader .
JOURNAL OF PEDIATRIC HEMATOLOGY ONCOLOGY, 2021, 43 (01) :E26-E28
[45]   Endocrinopathies, metabolic disorders, and iron overload in major and intermedia thalassemia: serum ferritin as diagnostic and predictive marker associated with liver and cardiac T2*MRI assessment [J].
Chirico, Valeria ;
Rigoli, Luciana ;
Lacquaniti, Antonio ;
Salpietro, Vincenzo ;
Piraino, Basilia ;
Amorini, Maria ;
Salpietro, Carmelo ;
Arrigo, Teresa .
EUROPEAN JOURNAL OF HAEMATOLOGY, 2015, 94 (05) :404-412
[46]   Cardiac and pancreatic iron overload evaluation of sickle/β-Thalassemia patients utilizing T2* MRI [J].
Orly Goitein ;
Eli Konen ;
Husam Ghoti ;
Ariel Koren ;
Carina Levine ;
Alain Berebi ;
Pinhas Stark ;
Eliezer Rachmilewitz .
Journal of Cardiovascular Magnetic Resonance, 11 (Suppl 1)
[47]   Correlation of Cardiac and Liver Iron Level with T2*MRI and Vitamin D3 Serum Level in Patients with Thalassemia Major [J].
Shaykhbaygloo, Roya ;
Moradabadi, Alireza ;
Taherahmadi, Hassan ;
Rafiei, Mohammad ;
Lotfi, Fariborz ;
Eghbali, Aziz .
JOURNAL OF BLOOD MEDICINE, 2020, 11 :83-87
[48]   Polymer-coated superparamagnetic iron oxide nanoparticles as T2 contrast agent for MRI and their uptake in liver [J].
Ali, Lamiaa M. A. ;
Marzola, Pasquina ;
Nicolato, Elena ;
Fiorini, Silvia ;
de las Heras Guillamon, Marcelo ;
Pinol, Rafael ;
Gabilondo, Lierni ;
Millan, Angel ;
Palacio, Fernando .
FUTURE SCIENCE OA, 2019, 5 (01)
[49]   Correlation between bone mineral densitometry and liver/heart iron overload evaluated by quantitative T2* MRI [J].
Ebrahimpour, Laleh ;
Akhlaghpoor, Shahram ;
Azarkayvan, Azita ;
Salehi, Maryam ;
Morteza, Afsaneh ;
Alinaghi, Reza .
HEMATOLOGY, 2012, 17 (05) :297-301
[50]   Quantitative MRI for hepatic fat fraction and T2* measurement in pediatric patients with non-alcoholic fatty liver disease [J].
Deng, Jie ;
Fishbein, Mark H. ;
Rigsby, Cynthia K. ;
Zhang, Gang ;
Schoeneman, Samantha E. ;
Donaldson, James S. .
PEDIATRIC RADIOLOGY, 2014, 44 (11) :1379-1387