A fully automatic parenchyma extraction method for MRI T2*relaxometry of iron loaded liver in transfusion-dependent patients

被引:0
作者
Lian, Zifeng [1 ,2 ,3 ,4 ,5 ,6 ]
Lu, Qiqi [1 ,2 ,3 ,4 ,5 ,6 ]
Lin, Bingquan [7 ]
Chen, Lingjian [8 ]
Gong, Jian [1 ]
Hu, Qiugen [1 ,8 ]
Wang, Huafeng [1 ,8 ]
Feng, Yanqiu [1 ,2 ,3 ,4 ,5 ,6 ,8 ]
机构
[1] Southern Med Univ, Sch Biomed Engn, Guangzhou, Peoples R China
[2] Southern Med Univ, Guangdong Prov Key Lab Med Image Proc, Guangzhou, Peoples R China
[3] Southern Med Univ, Guangdong Prov Engn Lab Med Imaging & Diagnost Tec, Guangzhou, Peoples R China
[4] Southern Med Univ, Guangdong Hong Kong Macao Greater Bay Area Ctr Bra, Guangdong Hong Kong Macao Greater Bay Area, Guangzhou, Peoples R China
[5] Southern Med Univ, Key Lab Mental Hlth, Minist Educ, Guangzhou, Peoples R China
[6] Southern Med Univ, Guangdong Hong Kong Joint Lab Psychiat Disorders, Guangzhou, Peoples R China
[7] Southern Med Univ, Nanfang Hosp, Dept Med Imaging Ctr, Guangzhou, Peoples R China
[8] Southern Med Univ, Shunde Hosp, Peoples Hosp Shunde 1, Dept Radiol, Foshan, Peoples R China
基金
中国国家自然科学基金;
关键词
Magnetic resonance imaging; T2*relaxometry; Liver iron loaded; Deep learning; Segmentation; SICKLE-CELL-DISEASE; WHOLE-LIVER; QUANTIFICATION; OVERLOAD; THALASSEMIA; RELAXOMETRY; THERAPY; STORES;
D O I
10.1016/j.mri.2024.02.017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop a fully automatic parenchyma extraction method for the T2* relaxometry of iron overload liver. Methods: A retrospective multicenter collection of liver MR examinations from 177 transfusion-dependent patients was conducted. The proposed method extended a semiautomatic parenchyma extraction algorithm to a fully automatic approach by introducing a modified TransUNet on the R2* (1/T2*) map for liver segmentation. Axial liver slices from 129 patients at 1.5 T were allocated to training (85%) and internal test (15%) sets. Two external test sets separately included 1.5 T data from 20 patients and 3.0 T data from 28 patients. The final T2* measurement was obtained by fitting the average signal of the extracted liver parenchyma. The agreement between T2* measurements using fully and semiautomatic parenchyma extraction methods was assessed using coefficient of variation (CoV) and Bland-Altman plots. Results: Dice of the deep network-based liver segmentation was 0.970 +/- 0.019 on the internal dataset, 0.960 +/- 0.035 on the external 1.5 T dataset, and 0.958 +/- 0.014 on the external 3.0 T dataset. The mean difference bias between T2* measurements of the fully and semiautomatic methods were separately 0.12 (95% CI: -0.37, 0.61) ms, 0.04 (95% CI: -1.0, 1.1) ms, and 0.01 (95% CI: -0.25, 0.23) ms on the three test datasets. The CoVs between the two methods were 4.2%, 4.8% and 2.0% on the internal test set and two external test sets. Conclusions: The developed fully automatic parenchyma extraction approach provides an efficient and operatorindependent T2* measurement for assessing hepatic iron content in clinical practice.
引用
收藏
页码:18 / 26
页数:9
相关论文
共 50 条
  • [31] Iron Overload in Patients With Heavily Transfused Sickle Cell Disease-Correlation of Serum Ferritin With Cardiac T2*MRI (CMRTools), Liver T2*MRI, and R2-MRI (Ferriscan®)
    Alkindi, Salam
    Panjwani, Vinodh
    Al-Rahbi, Sarah
    Al-Saidi, Khalid
    Pathare, Anil, V
    FRONTIERS IN MEDICINE, 2021, 8
  • [32] Myocardial iron overload assessment by T2*magnetic resonance imaging in adult transfusion dependent patients with acquired anemias
    Di Tucci, Anna Angela
    Matta, Gildo
    Deplano, Simona
    Gabbas, Attilio
    Depau, Cristina
    Derudas, Daniele
    Caocci, Giovanni
    Agus, Annalisa
    Angelucci, Emanuele
    HAEMATOLOGICA-THE HEMATOLOGY JOURNAL, 2008, 93 (09): : 1385 - 1388
  • [33] Quantitative T2*MRI for bone marrow iron overload: normal reference values and assessment in thalassemia major patients
    Meloni, Antonella
    Pistoia, Laura
    Restaino, Gennaro
    Missere, Massimiliano
    Positano, Vincenzo
    Spasiano, Anna
    Casini, Tommaso
    Cossu, Antonella
    Cuccia, Liana
    Massa, Antonella
    Massei, Francesco
    Cademartiri, Filippo
    RADIOLOGIA MEDICA, 2022, 127 (11): : 1199 - 1208
  • [34] Is cardiac and hepatic iron status assessed by MRI T2*associated with left ventricular function in patients with idiopathic cardiomyopathy?
    Kanzaki, Yumiko
    Yuki, Masako
    Yamamura, Ken-ichiro
    Narumi, Yoshifumi
    Ishizaka, Nobukazu
    HEART AND VESSELS, 2016, 31 (12) : 1950 - 1959
  • [35] Validation of a New T2*Algorithm and Its Uncertainty Value for Cardiac and Liver Iron Load Determination from MRI Magnitude Images
    Bidhult, Sebastian
    Xanthis, Christos G.
    Liljekvist, Love Lindau
    Greil, Gerald
    Nagel, Eike
    Aletras, Anthony H.
    Heiberg, Einar
    Hedstrom, Erik
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (04) : 1717 - 1729
  • [36] Evaluation of liver fat in the presence of iron with MRI using T2*correction: a clinical approach
    Benjamin, Henninger
    Christian, Kremser
    Stefan, Rauch
    Robert, Eder
    Werner, Judmaier
    Heinz, Zoller
    Henrik, Michaely
    Michael, Schocke
    EUROPEAN RADIOLOGY, 2013, 23 (06) : 1643 - 1649
  • [37] The role of MRI-R2* in the detection of subclinical pancreatic iron loading among transfusion-dependent sickle cell disease patients and correlation with hepatic and cardiac iron loading
    Basant Mohamed Raief Mosaad
    Ahmed Samir Ibrahim
    Mohamed G. Mansour
    Mohsen Saleh ElAlfy
    Fatma Soliman Elsayed Ebeid
    Emad H. Abdeldayem
    Insights into Imaging, 13
  • [38] The relationship between liver stiffness by two-dimensional shear wave elastography and iron overload status in transfusion-dependent patients
    Puttawibul, Pimporn
    Kritsaneepaiboon, Supika
    Chotsampancharoen, Thirachit
    Vichitkunakorn, Polathep
    PEDIATRIC HEMATOLOGY AND ONCOLOGY, 2024, 41 (06) : 409 - 421
  • [39] Hepatic Iron Deposition in Patients With Liver Disease: Preliminary Experience With Breath-Hold Multiecho T2*-Weighted Sequence
    Chandarana, Hersh
    Lim, Ruth P.
    Jensen, Jens H.
    Hajdu, Cristina H.
    Losada, Mariela
    Babb, James S.
    Huffman, Steve
    Taouli, Bachir
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (05) : 1261 - 1267
  • [40] Quantification of Superparamagnetic Iron Oxide-Mediated Signal Intensity Change in Patients With Liver Cirrhosis Using T2 and T2*Mapping: A Preliminary Report
    Chung, Yong Eun
    Park, Mi-Suk
    Kim, Myoung Soo
    Kim, Eunju
    Park, Jaeseok
    Song, Ho-Taek
    Choi, Jin Young
    Kim, Myeong-Jin
    Kim, Ki Whang
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (06) : 1379 - 1386