A fully automatic parenchyma extraction method for MRI T2*relaxometry of iron loaded liver in transfusion-dependent patients

被引:0
|
作者
Lian, Zifeng [1 ,2 ,3 ,4 ,5 ,6 ]
Lu, Qiqi [1 ,2 ,3 ,4 ,5 ,6 ]
Lin, Bingquan [7 ]
Chen, Lingjian [8 ]
Gong, Jian [1 ]
Hu, Qiugen [1 ,8 ]
Wang, Huafeng [1 ,8 ]
Feng, Yanqiu [1 ,2 ,3 ,4 ,5 ,6 ,8 ]
机构
[1] Southern Med Univ, Sch Biomed Engn, Guangzhou, Peoples R China
[2] Southern Med Univ, Guangdong Prov Key Lab Med Image Proc, Guangzhou, Peoples R China
[3] Southern Med Univ, Guangdong Prov Engn Lab Med Imaging & Diagnost Tec, Guangzhou, Peoples R China
[4] Southern Med Univ, Guangdong Hong Kong Macao Greater Bay Area Ctr Bra, Guangdong Hong Kong Macao Greater Bay Area, Guangzhou, Peoples R China
[5] Southern Med Univ, Key Lab Mental Hlth, Minist Educ, Guangzhou, Peoples R China
[6] Southern Med Univ, Guangdong Hong Kong Joint Lab Psychiat Disorders, Guangzhou, Peoples R China
[7] Southern Med Univ, Nanfang Hosp, Dept Med Imaging Ctr, Guangzhou, Peoples R China
[8] Southern Med Univ, Shunde Hosp, Peoples Hosp Shunde 1, Dept Radiol, Foshan, Peoples R China
基金
中国国家自然科学基金;
关键词
Magnetic resonance imaging; T2*relaxometry; Liver iron loaded; Deep learning; Segmentation; SICKLE-CELL-DISEASE; WHOLE-LIVER; QUANTIFICATION; OVERLOAD; THALASSEMIA; RELAXOMETRY; THERAPY; STORES;
D O I
10.1016/j.mri.2024.02.017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop a fully automatic parenchyma extraction method for the T2* relaxometry of iron overload liver. Methods: A retrospective multicenter collection of liver MR examinations from 177 transfusion-dependent patients was conducted. The proposed method extended a semiautomatic parenchyma extraction algorithm to a fully automatic approach by introducing a modified TransUNet on the R2* (1/T2*) map for liver segmentation. Axial liver slices from 129 patients at 1.5 T were allocated to training (85%) and internal test (15%) sets. Two external test sets separately included 1.5 T data from 20 patients and 3.0 T data from 28 patients. The final T2* measurement was obtained by fitting the average signal of the extracted liver parenchyma. The agreement between T2* measurements using fully and semiautomatic parenchyma extraction methods was assessed using coefficient of variation (CoV) and Bland-Altman plots. Results: Dice of the deep network-based liver segmentation was 0.970 +/- 0.019 on the internal dataset, 0.960 +/- 0.035 on the external 1.5 T dataset, and 0.958 +/- 0.014 on the external 3.0 T dataset. The mean difference bias between T2* measurements of the fully and semiautomatic methods were separately 0.12 (95% CI: -0.37, 0.61) ms, 0.04 (95% CI: -1.0, 1.1) ms, and 0.01 (95% CI: -0.25, 0.23) ms on the three test datasets. The CoVs between the two methods were 4.2%, 4.8% and 2.0% on the internal test set and two external test sets. Conclusions: The developed fully automatic parenchyma extraction approach provides an efficient and operatorindependent T2* measurement for assessing hepatic iron content in clinical practice.
引用
收藏
页码:18 / 26
页数:9
相关论文
共 50 条
  • [21] Assessment of Iron Distribution Between Liver, Spleen, Pancreas, Bone Marrow, and Myocardium by Means of R2 Relaxometry With MRI in Patients With β-Thalassemia Major
    Papakonstantinou, Olympia
    Alexopoulou, Efthymia
    Economopoulos, Nikos
    Benekos, Odysseas
    Kattamis, Antonis
    Kostaridou, Stavroula
    Ladis, Vasilis
    Efstathopoulos, Efstathios
    Gouliamos, Athanassios
    Kelekis, Nikolaos L.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (04) : 853 - 859
  • [22] Liver iron overload assessment by MRI R2*relaxometry in highly transfused pediatric patients: An agreement and reproducibility study
    Verlhac, S.
    Morel, M.
    Bernaudin, F.
    Bechet, S.
    Jung, C.
    Vasile, M.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2015, 96 (03) : 259 - 264
  • [23] Liver and Cardiac Iron Deposition in Patients on Maintenance Hemodialysis by Magnetic Resonance Imaging T2
    Tolouian, Ramin
    Mulla, Zuber D.
    Diaz, Jesus
    Aguila, Jorge
    Ramos-Duran, Luis
    IRANIAN JOURNAL OF KIDNEY DISEASES, 2016, 10 (02) : 68 - 74
  • [24] T2 relaxometry can lateralize mesial temporal lobe epilepsy in patients with normal MRI
    Bernasconi, A
    Bernasconi, N
    Caramanos, Z
    Reutens, DC
    Andermann, F
    Dubeau, F
    Tampieri, D
    Pike, BG
    Arnold, DL
    NEUROIMAGE, 2000, 12 (06) : 739 - 746
  • [25] Comparative Sequence Assessment of Optimised T2 and T2*Sequences for Quantification of Iron in Transfused Dependent Paediatric Sickle Cell Anaemia (SCA) Patients
    Ahmed, Azza
    Baldo, Amani
    Margani, Hind
    Fatah, Ahmed
    Idris, Ibrahim
    Salih, Isam
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 1, 2019, 68 (01): : 57 - 62
  • [26] The role of MRI-R2*in the detection of subclinical pancreatic iron loading among transfusion-dependent sickle cell disease patients and correlation with hepatic and cardiac iron loading
    Mosaad, Basant Mohamed Raief
    Ibrahim, Ahmed Samir
    Mansour, Mohamed G.
    ElAlfy, Mohsen Saleh
    Ebeid, Fatma Soliman Elsayed
    Abdeldayem, Emad H.
    INSIGHTS INTO IMAGING, 2022, 13 (01)
  • [27] Liver, bone marrow, pancreas and pituitary gland iron overload in young and adult thalassemic patients: a T2 relaxometry study
    Argyropoulou, Maria I.
    Kiortsis, Dimitrios N.
    Astrakas, Loukas
    Metafratzi, Zafiria
    Chalissos, Nikolaos
    Efremidis, Stavros C.
    EUROPEAN RADIOLOGY, 2007, 17 (12) : 3025 - 3030
  • [28] Validation of a standardized MRI method for liver fat and T2*quantification
    Hutton, Chloe
    Gyngell, Michael L.
    Milanesi, Matteo
    Bagur, Alexandre
    Brady, Michael
    PLOS ONE, 2018, 13 (09):
  • [29] Absence of cardiac siderosis by MRI T2*despite transfusion burden, hepatic and serum iron overload in Lebanese patients with sickle cell disease
    Inati, Adlette
    Musallam, Khaled M.
    Wood, John C.
    Sheikh-Taha, Marwan
    Daou, Linda
    Taher, Ali T.
    EUROPEAN JOURNAL OF HAEMATOLOGY, 2009, 83 (06) : 565 - 571
  • [30] Observational study of iron overload as assessed by magnetic resonance imaging in an adult population of transfusion-dependent patients with β thalassaemia: significant association between low cardiac T2*< 10 ms and cardiac events
    Patton, N.
    Brown, G.
    Leung, M.
    Bavishi, K.
    Taylor, J.
    Lloyd, J.
    Lee, S. -H.
    Tay, L.
    Worthley, S.
    INTERNAL MEDICINE JOURNAL, 2010, 40 (06) : 419 - 426