Analysis on a single-stage direct-coupled thermoacoustic refrigerator driven by low/medium-grade heat

被引:8
作者
Hu, Yiwei [1 ,2 ]
Xu, Jingyuan [3 ]
Zhao, Dan [4 ]
Yang, Rui [1 ]
Hu, Jianying [1 ,2 ]
Luo, Ercang [1 ,2 ]
机构
[1] Chinese Acad Sci, Tech Inst Phys & Chem, Key Lab Cryogen Sci & Technol, Beijing 100190, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[3] Karlsruhe Inst Technol, Inst Microstruct Technol, D-76344 Karlsruhe, Germany
[4] Univ Canterbury, Fac Engn, Dept Mech Engn, Private Bag 4800, Christchurch 8041, New Zealand
基金
中国国家自然科学基金;
关键词
Thermoacoustic refrigerator; Thermoacoustic; Heat-driven cooling; Low grade heat; Domestic cooling; SOLAR COOLING SYSTEM; WATER ADSORPTION CHILLER; AIR-CONDITIONING SYSTEM; PERFORMANCE ANALYSIS; DYNAMIC SIMULATION; ENERGY; COLLECTOR; DESIGN; TRNSYS;
D O I
10.1016/j.apenergy.2024.122958
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Cooling for domestic applications using low/medium-grade heat sources is essential to reduce CO2 emissions and promote environmental friendliness. Thermoacoustic technology is quite promising to meet such demand. This paper proposes a compact and highly efficient single-stage thermoacoustic refrigerator for utilizing low/mediumgrade heat source. It is different from conventional design by containing only one thermoacoustic core unit and enhancing cooling efficiency by improved acoustic matching incorporating a cavity structure with no less cooling performance than a multi-unit thermoacoustic refrigerators. For this, a matrix transfer method based on thermoacoustic theory is applied to investigate the onset characterizes of the thermoacoustic cooling system. The present results reveal that the lowest onset temperature difference of 62 K can be achieved when using nitrogen as the working gases. Steady-state characteristics of the system are then investigated, including the exergy loss analysis, the axial distributions of key parameters, cooling performance under different working conditions and mixed working gases. The analysis based on the introduced cavity is subsequently done in terms of the position, volume, and quantity of cavity. Further comparisons are made between the single-cavity and multi-cavity structures, demonstrating a superior performance of the single-cavity structure. Finally, the proposed thermoacoustic refrigerator is compared with existing heat-driven cooling technologies. The results demonstrate that the thermoacoustic refrigerator can compensate the deficiencies of the existing heat-driven cooling technologies at low cooling temperatures.
引用
收藏
页数:14
相关论文
共 70 条
[21]   Temperature Difference and Stack Plate Spacing Effects on Thermodynamic Performances of Standing-Wave Thermoacoustic Engines Driven by Cryogenic Liquids and Waste Heat [J].
Guo Lixian ;
Zhao Dan ;
Becker, Sid .
JOURNAL OF THERMAL SCIENCE, 2022, 31 (05) :1434-1451
[22]   Performance investigation of a solar-powered adsorption-based trigeneration system for cooling, electricity, and domestic hot water production [J].
Hassan, Ahmed A. ;
Elwardany, Ahmed E. ;
Ookawara, Shinichi ;
El-Sharkawy, Ibrahim I. .
APPLIED THERMAL ENGINEERING, 2021, 199
[23]   Thermoacoustic heat pump utilizing medium/low-grade heat sources for domestic building heating [J].
Hu Y. ;
Luo K. ;
Zhao D. ;
Wu Z. ;
Yang Y. ;
Luo E. ;
Xu J. .
Energy and Built Environment, 2024, 5 (04) :628-639
[24]   A thermoacoustic cooler with a bypass expansion for distributed-temperature heat loads [J].
Hu, Yiwei ;
Wang, Xin ;
Wu, Zhanghua ;
Zhang, Limin ;
Chen, Geng ;
Xu, Jingyuan ;
Luo, Ercang .
APPLIED PHYSICS LETTERS, 2022, 121 (20)
[25]   Performance characteristics of a solar driven lithium bromide-water absorption chiller integrated with absorption energy storage [J].
Ibrahim, Nasiru I. ;
Al-Sulaiman, Fahad A. ;
Ani, Farid Nasir .
ENERGY CONVERSION AND MANAGEMENT, 2017, 150 :188-200
[26]   Acoustic field characteristics and performance analysis of a looped travelling-wave thermoacoustic refrigerator [J].
Jin, T. ;
Yang, R. ;
Wang, Y. ;
Feng, Y. ;
Tang, K. .
ENERGY CONVERSION AND MANAGEMENT, 2016, 123 :243-251
[27]   Phase adjustment analysis and performance of a looped thermoacoustic prime mover with compliance/resistance tube [J].
Jin, Tao ;
Yang, Rui ;
Wang, Yi ;
Liu, Yuanliang ;
Feng, Ye .
APPLIED ENERGY, 2016, 183 :290-298
[28]  
Johnson I., 2008, Waste Heat Recovery: Technology and Opportunities in the U.S. Industry
[29]   Application of solar assisted heating and desiccant cooling systems for a domestic building [J].
Joudi, KA ;
Dhaidan, NS .
ENERGY CONVERSION AND MANAGEMENT, 2001, 42 (08) :995-1022
[30]   Global warming's impact on the performance of GSHP [J].
Kharseh, Mohamad ;
Altorkmany, Lobna ;
Nordell, Bo .
RENEWABLE ENERGY, 2011, 36 (05) :1485-1491