HPLC-MS/MS Method for the Quantitative Determination of Metformin in Rat Plasma and Its Application to Comparative Bioavailability Assessment

被引:0
作者
Zhang, Di-Di [1 ]
Jung, Young-Heun [1 ]
Seol, Mi-Ji [1 ]
Zhou, Siyu [1 ]
Chaudhary, Dinesh [2 ]
Jeong, Jee-Heon [2 ]
Kim, Ju-Hyun [1 ]
机构
[1] Yeungnam Univ, Coll Pharm, Gyongsan 38541, South Korea
[2] Sungkyunkwan Univ, Sch Med, Dept Precis Med, Suwon 16419, South Korea
关键词
Metformin; bioavailability; subcutaneous; LC-MS/MS; rat plasma; comparative bioavailability assessment; DRUG; PHARMACOKINETICS; TRANSPORTERS; RELEASE;
D O I
10.2174/0115734110288849240116045045
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background Metformin is a biguanide derivative utilized as a first-line treatment for type 2 diabetes for people over 60 years. However, it faces certain limitations due to its incomplete absorption, resulting in a 50-60% bioavailability. In addition to its blood glucose-lowering effect, the antiproliferative effect of metformin has been demonstrated in vitro. Therefore, it is necessary to consider alternative administration routes that can enhance the bioavailability of metformin, expanding its clinical use beyond its role as an antidiabetic agent.Objective The aim of the study was to develop a reliable bioanalytical method for the quantitation of metformin in male Sprague-Dawley rat plasma and explore the promising alternative administration route for metformin use.Methods A robust, high-performance liquid chromatography-tandem mass spectrometry method for the quantification of metformin in rat plasma was developed and validated according to the latest regulatory guidance for bioanalysis.Results Based on the area under the curves obtained from the rat pharmacokinetic study, subcutaneous injection increased the systemic exposure of metformin by 1.79-fold compared to oral administration in rats.Conclusion Subcutaneous administration of metformin enhances its bioavailability compared to oral administration, leading to increased antidiabetic effects and potential antitumor activity.
引用
收藏
页码:255 / 263
页数:9
相关论文
共 93 条
[1]   Transdermal Delivery of Metformin Using Dissolving Microneedles and Iontophoresis Patches for Browning Subcutaneous Adipose Tissue [J].
Abbasi, Mehrnaz ;
Fan, Zhaoyang ;
Dawson, John A. ;
Wang, Shu .
PHARMACEUTICS, 2022, 14 (04)
[2]   Non-enzymatic electrochemical sensor to detect γ-aminobutyric acid with ligand-based on graphene oxide modi fied gold electrode [J].
Alamry, Khalid A. ;
Hussein, Mahmoud A. ;
Choi, Jeong-woo ;
El-Said, Waleed A. .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2020, 879
[3]   Fabrication of gold/graphene nanostructures modified ITO electrode as highly sensitive electrochemical detection of Aflatoxin B1 [J].
Althagafi, Ismail I. ;
Ahmed, Saleh A. ;
El-Saidid, Waleed A. .
PLOS ONE, 2019, 14 (01)
[4]  
[Anonymous], 2021, Eco-friendly modified carbon paste electrode by Bigarreau Burlat kernel shells for simultaneous trace detection of cadmium, lead, DOI DOI 10.1016/J.CDC.2020.100642
[5]   Development of an Injectable Slow-Release Metformin Formulation and Evaluation of Its Potential Antitumor Effects [J].
Baldassari, Sara ;
Solari, Agnese ;
Zuccari, Guendalina ;
Drava, Giuliana ;
Pastorino, Sara ;
Fucile, Carmen ;
Marini, Valeria ;
Daga, Antonio ;
Pattarozzi, Alessandra ;
Ratto, Alessandra ;
Ferrari, Angelo ;
Mattioli, Francesca ;
Barbieri, Federica ;
Caviglioli, Gabriele ;
Florio, Tullio .
SCIENTIFIC REPORTS, 2018, 8
[6]   Electrochemical detection of copper ions leached from CuO nanoparticles in saline buffers and biological media using a gold wire working electrode [J].
Baldisserri, Carlo ;
Costa, Anna Luisa .
JOURNAL OF NANOPARTICLE RESEARCH, 2016, 18 (04)
[7]   Electrochemical sensor based on polystyrene sulfonate-carbon nanopowders composite for Cu (II) determination [J].
Cantalapiedra, Alberto ;
Jesus Gismera, Ma ;
Procopio, Jesus R. ;
Teresa Sevilla, Ma .
TALANTA, 2015, 139 :111-116
[8]   Pharmacologic Approaches to Glycemic Treatment: Standards of Medical Care in Diabetes-2019 [J].
Cefalu, William T. ;
Berg, Erika Gebel ;
Saraco, Mindy ;
Petersen, Matthew P. ;
Uelmen, Sacha ;
Robinson, Shamera .
DIABETES CARE, 2019, 42 :S90-S102
[9]   Microparticulate and nanoparticulate drug delivery systems for metformin hydrochloride [J].
Cetin, Meltem ;
Sahin, Selma .
DRUG DELIVERY, 2016, 23 (08) :2796-2805
[10]   Graphene Fluorescence Resonance Energy Transfer Aptasensor for the Thrombin Detection [J].
Chang, Haixin ;
Tang, Longhua ;
Wang, Ying ;
Jiang, Jianhui ;
Li, Jinghong .
ANALYTICAL CHEMISTRY, 2010, 82 (06) :2341-2346