Power Balance Method of Cascaded H-Bridge Inverter Based on Pulse Circulation in Output Period

被引:0
作者
Chen Z. [1 ]
Sun J. [1 ]
Xu Y. [2 ]
Wang K. [1 ]
机构
[1] Jiangsu Key Laboratory of New Energy Generation and Power Conversion, Nanjing University of Aeronautics and Astronautics, Nanjing
[2] Shenzhen Hopewind Electric Co. Ltd, Shenzhen
来源
Diangong Jishu Xuebao/Transactions of China Electrotechnical Society | 2020年 / 35卷 / 04期
关键词
Cascaded H-bridge; Comparative analysis; Output period; Power balance; Pulse circulation;
D O I
10.19595/j.cnki.1000-6753.tces.181870
中图分类号
学科分类号
摘要
For cascaded H-bridge inverter, in order to realize power balance control between cascaded cells and harmonic characteristics control of inverter output line voltage, this paper redistributed the output of cascaded cells based on carrier control degree of freedom. Two power balance methods based on quarter and half output period pulse circulation were proposed. The proposed methods could control cascaded cells to achieve power balance within 3/2 output periods at any modulation ratio and power factor angle. In order to simplify implementation process, the proposed methods were optimized twice, so that the number of carriers and the number of carrier adjustment time were greatly reduced. At the same time, the similarities and differences between the original methods and the optimized methods were compared and analyzed. The results show that second optimization method based on half output period pulse circulation obtains the best optimization effect. Finally, the experimental results verified the correctness of theoretical analysis and feasibility of power balance control methods. © 2020, Electrical Technology Press Co. Ltd. All right reserved.
引用
收藏
页码:827 / 838
页数:11
相关论文
共 17 条
[1]  
Sahoo S.K., Bhattacharya T., Phase-shifted carrier-based synchronized sinusoidal PWM techniques for a cascaded H-bridge multilevel inverter, IEEE Transactions on Power Electronics, 33, 1, pp. 513-524, (2018)
[2]  
Kandasamy K., Vilathgamuwa M., Tseng K.J., Inter-module state-of-charge balancing and fault-tolerant operation of cascaded H-bridge converter using multi-dimensional modulation for electric vehicle application, IET Power Electronics, 8, 10, pp. 1912-1919, (2015)
[3]  
Reddy B.P., A M.R., Sahoo M., Et al., A fault-tolerant multilevel inverter for improving the performance of a pole-phase modulated nine-phase induction motor drive, IEEE Transactions on Industrial Electronics, 65, 2, pp. 1107-1116, (2018)
[4]  
Chen Y., Wen M., Yin X., Et al., Principle and design of the cascaded STATCOM integrated with distribution transformer, Transa-ctions of China Electrotechnical Society, 33, 12, pp. 2861-2872, (2018)
[5]  
Zabalza J.C., Moreno P.I., Madariaga D., Et al., Voltage balancing control in 3-level neutral-point clamped inverters using triangular carrier PWM modulation for FACTS applications, IEEE Transactions on Power Electronics, 28, 10, pp. 4473-4484, (2013)
[6]  
Ge B., Liu Y., Abu-Rub H., Et al., State-of-charge balancing control for a battery-energy-stored quasi-Z-source cascaded multilevel inverter based photovoltaic power system, IEEE Transactions on Industrial Electronics, 65, 3, pp. 2268-2279, (2018)
[7]  
Hammond P.W., A new approach to enhance power quality for medium voltage AC drives, IEEE Transactions on Industry Applications, 33, 1, pp. 202-208, (1997)
[8]  
Rech C., Pinheiro J.R., Line current harmonics reduction in multipulse connection of asymmetrically loaded rectifiers, IEEE Transactions on Industrial Electronics, 52, 3, pp. 640-652, (2005)
[9]  
Tolbert L.M., Peng F., Cunnyngham T., Et al., Charge balance control schemes for cascade multi-level converter in hybrid electric vehicles, IEEE Transactions on Industrial Electronics, 49, 5, pp. 1058-1064, (2002)
[10]  
Monopoli V.G., Marquez A., Leon J.I., Et al., Improved harmonic performance of cascaded H-bridge con-verters with thermal control, IEEE Transactions on Industrial Electronics, 66, 7, pp. 4982-4991, (2019)